• 제목/요약/키워드: 수소충전

검색결과 255건 처리시간 0.027초

CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구 (A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System)

  • 황순일;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.

필터가 장착된 수소충전시스템용 리셉터클의 작동부 형상에 따른 유동 성능 분석 (Analysis of Flow Performance According to Actuator Geometry of Receptacle for Hydrogen Charging System with Filter Applied)

  • 최주환;김구호;김재광;김용기;서현규
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.17-25
    • /
    • 2023
  • The purpose of this study was to propose a design that shows optimal performance by changing the geometry of the internal flow path of the receptacle in order to prevent the decrease in flow rate and differential pressure performance due to the application of the receptacle in the hydrogen charging system. To achieve this, 3D computational fluid dynamics simulation was performed for the receptacle, according to the geometry of the flow path inside the receptacle. The pressure results at the inlet and outlet were measured the same as both of N and H2 in the experiment, and the flow rate of H2 was 3.75 times higher than that of N2. In addition, since the flow performance of the receptacle improved under conditions where the flow path was widened, it was confirmed that reducing the diameter of the poppet and the width of the guide are advantageous for improving performance.

Type IV 고세장비 모듈형 수소저장용기의 충전 조건에서의 수치해석적 연구 (A Numerical Analysis Study on Charging Conditions of Type IV High Aspect Ratio Modular Hydrogen Storage Vessel)

  • 백중택;문지훈;민지훈;박균범;기광택;주성욱
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.26-31
    • /
    • 2023
  • In this study, in order to propose a modular method for type IV high aspect ratio modular hydrogen storage vessel, a numerical analysis was conducted on the heat transfer behavior in series and parallel connection methods, and the differences according to each connection method were reviewed. Computational fluid dynamics software was used to check the internal temperature and pressure values of the hydrogen storage container under charging conditions. In terms of thermal safety when charging hydrogen gas, it was confirmed that the parallel modularization method was superior.

디스펜서를 이용한 차량용 연료 탱크 수소 충전 모델링에 관한 연구 (A Study on the Modeling of Fueling Hydrogen Tank in Vehicle Using Dispenser)

  • 최지아;지상원;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권2호
    • /
    • pp.36-44
    • /
    • 2022
  • Hydrogen energy as an alternative source of energy has been receiving tremendous support around the world, and research is being actively conducted accordingly. However, most of the studies focus on hydrogen storage tanks and only are few studies on interpreting the hydrogen filling system itself. In this study, with reference to SAE J2601, a hydrogen fueling protocol, a simulation model was developed that can confirm the behavior of the vehicle's internal tank during hydrogen fueling. With respect to factors such as fuel supply temperature, ambient temperature, and pressure increase rate, the developed model can check the change of temperature and pressure in the tank and the state of hydrogen charging during hydrogen fueling. The validity of the developed simulation model was confirmed by comparing the simulation results with the experimental results presented in SAE J2601.

Type II 고압수소저장용기의 충전과 방출에 의한 권선 거동 관찰의 기계적 방법에 관한 연구 (A Study on the Mechanical Method of Observing Winding Behavior by Charging and Discharging of Type II High Pressure Hydrogen Storage Tank)

  • 김승환;한진목;이성희;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제33권2호
    • /
    • pp.158-163
    • /
    • 2022
  • The test method on the Type II high-pressure hydrogen storage tanks made of the metal wire hoop winding is a complex and high risk. Also closeup on the tank being test is difficult. In this study, we studied a mechanical test method for a high-pressure hydrogen tanks. This method must be simple, risk-free and possible to observe the change in microscopic behavior of a metal wire on a liner. As the results, it was possible to observe the microscopic behavior on the metal wire by the mechanical test method. Also, a simple and risk-free test was possible compared to the conventional test method for high pressure hydrogen tanks.

FCEV 충전 시스템 체크밸브의 수소 유입 극한 온도 조건에 따른 유동 성능 인자 분석 (Analysis of Flow Performance Factors According to Extreme Temperature Conditions of Hydrogen Inflow of FCEV Charging System Check Valve)

  • 오승훈;서현규
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.514-525
    • /
    • 2023
  • This study conducted numerical simulations with the purpose of analyzing the impact of variations in outlet pressure conditions under extreme temperature conditions on the fluid dynamics and performance of a check valve utilized in hydrogen refueling systems. Under the extreme temperature conditions, changes in outlet pressure conditions of the check valve were investigated to analyze velocity distributions, pressure distributions, and temperature distributions in the operational and connection regions. The analysis results indicated that changes in outlet pressure had a significant influence on the internal temperature variation of the check valve. Furthermore, due to density variations in the connection region caused by the cooling effect of excessively cooled hydrogen, a bias in the primary flow direction towards the lower part of the valve outlet was observed in the outlet area. Through a comparison of the results of the valve's inherent flow performance, represented by the flow coefficient, it was observed that when the pressure difference between the inlet and outlet was below 0.37 MPa, sufficient flow was not ensured.

급속 충전에서 탱크 내부의 수소 온도 변화에 관한 이론 연구 (A Theoretical Study on the Hydrogen Temperature Evolution Inside the Tank under Fast Filling Process)

  • 이길초;이길강;허항;최병철;권정태
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.608-614
    • /
    • 2023
  • The fast filling process of high-pressure hydrogen has an important impact on the filling efficiency and safety. In this paper, a specific study is carried out on the thermophysical phenomena during the fast filling process. Starting from the gas state equation of hydrogen, the change law of the hydrogen storage temperature is obtained, and then the temperature rise prediction is constructed. The model can clarify the relationship between the filling parameters and the temperature rise during the fast filling process, thereby revealing the flow and heat transfer laws of the fast charging process. To improve the theoretical research basis for the evaluation of vehicle-mounted hydrogen fast charging capacity, temperature prediction and optimization of hydrogenation methods.

수소 충전소

  • 서동주;윤왕래
    • 대한설비공학회지:설비저널
    • /
    • 제36권9호
    • /
    • pp.36-41
    • /
    • 2007
  • PDF

액화수소 충전스테이션에서 VCE로 인한 피해영향평가에 관한 연구 (A Study on the Evaluations of Damage Impact due to VCE in Liquid Hydrogen Charging Station)

  • 이수지;천영우;이익모;황용우
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.56-63
    • /
    • 2017
  • 전세계적으로 수소 충전 스테이션 구축에 많은 투자와 지원을 하고 있는 실정이다. 그러나 수소는 폭발범위가 넓고 확산이 빠른 기체이다. 본 연구에서는 액화수소를 취급하는 소규모~대규모 충전스테이션을 대상으로, 사고시 발생하는 VCE로 인한 피해영향범위를 산출하고, 프로빗 모델을 통해 주변의 인적, 물적 피해를 예측하였다. 더불어, 벤트스택 끝단에서 발생 가능한 Jet fire를 시나리오로 선정하여 최적 높이를 설정하였다. 피해영향범위는 관심과압 6.9kPa을 기준으로 하여, 소규모 저장시설의 경우 8.24m, 중규모 14.10m, 대규모 22.38m이다. 폐출혈로 인한 인체 피해는 소규모와 중규모가 각각 50m, 대규모 100m였으며, 구조물 손상에 따른 피해는 소규모 200m, 중규모 300m 및 대규모 500m이다. 벤트스택의 최적높이는 소규모 4.7m, 중규모 8.8m 및 대규모 16.9m이다.