• Title/Summary/Keyword: 수소충전

Search Result 256, Processing Time 0.026 seconds

Risk Assessment of Tube Trailer Leaks at Hydrogen Charging Station (수소충전소 튜브트레일러 누출에 따른 위험성평가)

  • Park, Woo-Il;Yoon, Jin-Hee;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.57-62
    • /
    • 2021
  • In this study, risk assessment was conducted in case of leakage of storage facilities (tube trailer) using the HyKoRAM program developed through international joint research. The high-pressure gas facilities in the hydrogen filling station are divided into four main categories: storage facilities (tube trailers), processing facilities (compressors), compressed gas facilities, and filling facilities (dispensers). Among them, the design specifications of the tube trailer, which is a storage facility, and the surrounding environmental conditions were reflected to construct an accident scenario with previously occurring accidents and potential accidents. Through this, we identify the risks of storage facilities at hydrogen refueling stations and suggest measures to improve the safety of hydrogen charging stations.

Hydraulic Compressor Safety Test for Hydrogen Stations (수소충전소용 유압식 압축기 안전성 시험에 관한 연구)

  • Seong, Hye-Jin;Hwang, Bom-Chan;Choi, Sung-Joon;Kim, Young-Kyu;Cho, Sung-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.8-15
    • /
    • 2020
  • The government has announced its Hydrogen Economy Roadmap to strengthen global competitiveness on the hydrogen economy by focusing on hydrogen fuel cell electric vehicles and fuel cells. In this regard, the interest on the economics and safety of the infrastructure of hydrogen stations has also increased. In this study, a test bed similar to an actual hydrogen charging facility was built, and a prototype of a piston-type compressor was modeled. In this model, the piston was hydraulically compressed to progressively test leakage, leakage rate, and durability and to check for any malfunction. Moreover, the leakage rate, cylinder leak performance, and compressor operation durability were evaluated for safety; it was confirmed that there were no abnormalities. Nevertheless, an investigation of the long-term use and operating pressure of the compressor is necessary to verify the safety of developing a100-MPa domestic compressor in the future.

Numerical Analysis of Fillling Flow in Type III Hydrogen Tank with Different Turbulence Models (Type III 수소 저장 용기에서 난류 모델(Turbulence Model)에 따른 충전(Filling)현상의 수치 해석적 연구)

  • KIM, MOO-SUN;RYU, JOON-HYOUNG;LEE, SUNG-KWON;CHOI, SUNG-WOONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.483-488
    • /
    • 2021
  • With continuous emission of environmental pollutants and an increase in greenhouse gases such as carbon dioxide, demand to seek other types of energy sources, alternative energy, was needed. Hydrogen, an eco-friendly energy, is attracting attention as the ultimate alternative energy medium. Hydrogen storage technology has been studied diversely to utilize hydrogen energy. In this study, the gas behavior of hydrogen in the storage tank was numerically examined under charge conditions for the Tpe III hydrogen tank. Numerical results were compared with the experimental results to verify the numerical implementation. In the results of pressure and temperature values under charge condition, the Realizable k-ε model and Reynold stress model were quantitatively matched with the smallest error between numerical and experimental results.

A Study on the Improvement of Safety Instrumented Function of Hydrogen Refueling Station Considering Individual Risk (개인적 위험도를 고려한 수소충전소의 안전계장기능 향상에 관한 연구)

  • YOON SUP BYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.297-306
    • /
    • 2023
  • The frequency of fatal accidents that can occur at hydrogen refueling station was compared with the risk criterion for the general public suggested by the health and safety executive. If hydrogen refueling station meets the accident prevention facility standards presented in KGS Code FP216/217, it was confirmed that the risk of hydrogen refueling station was not at an unacceptable (intolerable) risk level. However, the risk of hydrogen refueling station due to small leak was analyzed as low as reasonably practicable. Therefore, methods for improving the safety instrumented function of hydrogen refueling station were reviewed. It was confirmed that the risk of hydrogen refueling station can be affected by the number of installed safety instrumentation system components, redundant architecture, mission time, proof test interval, etc. And methods for maintaining the risk of hydrogen refueling station at an acceptable risk level have been proposed.

Biofiltration of soil Vapor Extraction Off-gas from Gasoline Contaminated Soil Using a Compost (퇴비를 이용한 가솔린 오염토양증기추출 배가스의 바이오필터 처리)

  • 남궁완;박준석
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.25-33
    • /
    • 1999
  • The recent emergence of biofiltration as a cost effective waste-gas control technology has stimulated in European countries and the USA. Biofiltration of soil vapor extraction off-gas from gasoline contaminated site was simulated in lab-scale in this study. A filling material used was a compost. This study was conducted to evaluate biofiltration characteristics of the compost material for gasoline off-gas. TPH elimination capacity at the gas loading rate of about 50g/$\textrm{m}^3$((filling material)/hr was circa 40g/$\textrm{m}^3$((filling material)/hr. Removal rate of xylene was the highest among BTEX. while it was the lowest in case of bezene. The maximum elimination capacity of the compost was about 1.5g/$\textrm{m}^3$((filling material)/hr for benzene. More than 95% of trimethylbenzene and naphtalene were removed below the loading rate of 0.7g/㎥(filling material)/hr. About 80% of total TPH and BTEX were removed by biodegradation.

  • PDF

Investigation on Chilling Procedure for LOX Supply System for Liquid Rocket Engine (액체로켓엔진 산화제 공급부 냉각과정 고찰)

  • Cho, Nam-Kyung;Seo, Dae-Bahn;Yoo, Byung-Il;Kim, Seong-Han;Han, Yeoung-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.119-126
    • /
    • 2019
  • For rockets using cryogenic liquid hydrogen or liquid oxygen, chilling is required to avoid cavitation and surge problems. Chilling is categorized by the initial chilling/filling stage and the low-temperature maintenance stage. In addition, to improve satellite insertion capability, a multi-ignition capability is required and accordingly chilling to prepare for the next ignition during low-gravity coasting is also required. This paper describes the overall aspects of filling and low temperature maintain marinating for the booster and the upper stage engine including chilling for multi-ignition.

A Study of the Electric Vehicle Industry and Policy Implications (전기자동차 산업 현황 및 정책적 대응방향)

  • Chun, Hwang-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.471-473
    • /
    • 2013
  • This paper is analyzing the situation of the electric vehicle Industry and draw the policy implications to promote electric vehicle industry. Major automobile makers as GM, BMW, Nissan, Audi produce various electric vehicles. But in recent times, only few electric vehicle sold in the world. So, many automobile makers gave up the production of electric vehicles. and the fuel-cell vehicle will replace the electric vehicle as a environment car in the future. We should take the build up of eco system between vehicle makers and the small parts companies, construction of battery charging infrastructure, promotion of standardization activities, and the government's support to revive the electric vehicle industry.

  • PDF

Characteristics of Bed Media for Reducing Odor from Livestock Facilities (축사 악취저감을 위한 바이오필터 충전재의 악취제거 특성)

  • 한원석;장동일;방승훈;이승주
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2003
  • This study designed and constructed an experimental column far adhesion efficiency test and conducted experiment to investigate the offensive odor adhesion efficiency of filter bed materials. The offensive odor adhesion experiment was conducted using mixture of high physical adhesion efficiency material, and the fixity of deodorization microorganism of selected filter bed material was tested using ammonia exclude microorganism A4-­2 and sulfur oxidation microorganism S5­-5.2 those were cultured at the Agricultural Chemical Department of Chungnam National University, and deodorization efficiency of selected filter bed material mixture was tested. Following are summary of these tests results. 1. Amount of elimination of the offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.054 and 0.016$\ell/\textrm{cm}^3$ in rice hull, 0.01 and 0.004 $\ell/\textrm{cm}^3$ in rice straw 0.158 and 0.01 $\ell/\textrm{cm}^3$ in coconut, 0.014 and 0.02$\ell/\textrm{cm}^3$ perlite, 0.004 and 0.003$\ell/\textrm{cm}^3$ in high road ball, and 0.112 and 0.015 $\ell/\textrm{cm}^3$ in chaff of pine, respectively. 2. Amount of elimination of offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.045 and 0.014$\ell/\textrm{cm}^3$ in mixture 1, 0.079 and 0.016$\ell/\textrm{cm}^3$ in mixture 2, 0.123 and 0.017 $\ell/\textrm{cm}^3$ in mixture 3, 0.031 and 0.015$\ell/\textrm{cm}^3$ in mixture 4, 0.055 and 0.016$\ell/\textrm{cm}^3$ in mixture 5, and 0.111 and 0.020$\ell/\textrm{cm}^3$ in mixture 6, respectively. 3. The offensive odor elimination microorganism inoculated to mixture of chaff of pine(70%) and perlite(30%) showed the elimination efficiency of 99.06% and 96.61% against the ammonia and hydrogen sulfide, respectively, during 24 hours period.

  • PDF

Design and Performance Test of a Direct Cooling Equipment for Hydrogen Liquefaction (수소액화용 직접냉각장치의 설계 및 성능시험)

  • Baik, Jong-Hoon;Kang, Byung-Ha;Chang, Ho-Myung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1996
  • A direct cooling equipment for hydrogen liquefaction has been developed and tested. A direct cooling equipment consists of a liquefaction vessel, a radiation shield, a cryostat and a GM refrigerator. The cool-down and warm-up characteristics of the liquefaction apparatus have been investigated in detail. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 45 minutes of cool-down. The cool-down and warm-up tests of helium gas are also performed. The cool-down and warm-up characteristics of helium gas are found to be very different from those of hydrogen gas, since helium is not liquefied under the present operating conditions. When the liquefaction vessel is evacuated, natural convection phenomena of charged gas in liquefaction vessel can be removed. It is seen that the cool-down time of liquefaction vessel is substantially increased in vacuum environment.

  • PDF

Influence of Filler Particle Size on Behaviour of EPDM Rubber for Fuel Cell Vehicle Application under High-Pressure Hydrogen Environment (수소전기차용 EPDM 고무의 충전재 입자 크기별 고압 수소 환경에서의 거동 연구)

  • KIM, KEEJUNG;JEON, HYEONG-RYEOL;KANG, YOUNG-IM;KIM, WANJIN;YEOM, JIWOONG;CHOI, SUNG-JOON;CHO, SUNGMIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.453-458
    • /
    • 2020
  • In this study, ethylene-propylene-diene monomer (EPDM) rubbers reinforced with various particle size of carbon black were prepared and tested. We followed recently published CSA/ANSI CHMC2 standard "the test methods for evaluating material compatibility in compressed hydrogen applications-polyemr". Measurement of change in hardness, tensile strength and volume were performed after exposure to maximum operating pressure, 87.5 MPa, for 168 hours (1 week). Once EPDM was exposed to high-pressure hydrogen, the samples experience volume increase and degradation of the physical properties. Also, after the dissolved hydrogen was fully eliminated from the specimens, the hardness and the tensile properties were not recovered. The rubber reinforced with smaller sizes of carbon black particles showed less volume expansion and decrease of physical properties. As a result, smaller particle size of carbon black filler led to more resistance to high-pressure hydrogen.