• Title/Summary/Keyword: 수소저장시스템

Search Result 106, Processing Time 0.032 seconds

Life Cycle Assessment (LCA) and Energy Efficiency Analysis of Fuel Cell Based Energy Storage System (ESS) (연료전지 기반 에너지저장 시스템의 환경 전과정평가 및 에너지 효율성 분석)

  • KIM, HYOUNGSEOK;HONG, SEOKJIN;HUR, TAK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.156-165
    • /
    • 2017
  • This study quantitatively assessed the environmental impacts of fuel cell (FC) systems by performing life cycle assessment (LCA) and analyzed their energy efficiencies based on energy return on investment (EROI) and electrical energy stored on investment (ESOI). Molten carbonate fuel cell (MCFC) system and polymer electrolyte membrane fuel cell (PEMFC) system were selected as the fuel cell systems. Five different paths to produce hydrogen ($H_2$) as fuel such as natural gas steam reforming (NGSR), centralized naptha SR (NSR(C)), NSR station (NSR(S)), liquified petroleum gas SR (LPGSR), water electrolysis (WE) were each applied to the FCs. The environmental impacts and the energy efficiencies of the FCs were compared with rechargeable batteries such as $LiFePO_4$ (LFP) and Nickel-metal hydride (Ni-MH). The LCA results show that MCFC_NSR(C) and PEMFC_NSR(C) have the lowest global warming potential (GWP) with 6.23E-02 kg $CO_2$ eq./MJ electricity and 6.84E-02 kg $CO_2$ eq./MJ electricity, respectively. For the impact category of abiotic resource depletion potential (ADP), MCFC_NGSR(S) and PEMFC_NGSR(S) show the lowest impacts of 7.42E-01 g Sb eq./MJ electricity and 7.19E-01 g Sb eq./MJ electricity, respectively. And, the energy efficiencies of the FCs are higher than those of the rechargeable batteries except for the case of hydrogen produced by WE.

Experimental Study on Bi-directional Air Cooling System for 18650 Li-ion Battery Module to Minimize Cell-to-Cell Temperature Variation (18650 Li-ion battery Module의 Cell-to-Cell 온도 편차 최소화를 위한 양방향 냉각에 대한 실험적 연구)

  • JANG, HOSUN;PARK, MINGYU;JEON, JIWHAN;PARK, SEONGSU;KIM, TAEWOO;PARK, SUNGJIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.407-418
    • /
    • 2017
  • Battery heat management is essential for high power and high energy battery system because it affects its performance, longevity, and safety. In this paper, we investigated the temperature of the 18650 Lithium Ion Battery Module used in a Energy Storage System (ESS) and the cooling method to minimize cell-to-cell temperature variation of battery module. For uniform temperature distribution within a battery module, the flow direction of the coolant in a battery module has been changed according to the time interval, and studied the effect of the cooling method on the temperature uniformity in a battery module which includes a number of battery cells. The experimental results show that bi-directional battery cooling method can effectively reduce the cell-to-cell temperature variation compared with the one-directional battery cooling. Furthermore, it is also found that bi-directional battery cooling can reduce the maximum temperature in a battery module.

Performance evaluation and Applicable Possibility of $H_2O_2$ Gas Generator using Dual Catalyst System (이원 촉매를 이용한 과산화수소 가스발생기 성능평가 및 응용 가능성)

  • Rang Seong-Min;An Sung-Yong;Lim Ha-Young;Kwon Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.347-350
    • /
    • 2006
  • The rocket grade hydrogen peroxide has been widely used as a monopropellant in propulsion systems. In the present paper, we described an experimental study of a catalytic reactor that employs two stage catalyst beds to enhance the low temperature performance of the reactor. $K_2MnO_4$ was chosen as the catalyst for the initial stage of the reactor bed for its superior behavior in the low temperature regime. LSC was used for the catalyst of the second stage of the reactor. The gas generator with combined catalyst beds was built and tested to exhibit high decomposition efficiency over 90% and successful cold-start characteristics.

  • PDF

Study on the design factor to scale up the zinc/air fuel cell (아연/공기전지의 scale-up을 위한 설계인자 연구)

  • Lee, Hoil;Oh, Taeyoung;Park, Sangmin;Kim, Jungyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.74.2-74.2
    • /
    • 2010
  • 전세계는 $CO_2$ 규제강화와 에너지의 효율적 사용에 대한 사회적, 경제적 요구가 증대되면서 친환경 에너지 설비와 지능형 전력망(smart grid)가 크게 예상되고 있다. 이에 따라 기존 내연기관에 근거한 발전산업 및 자동차 산업은 필연적으로 청정에너지 기반의 전기에너지로 점진적으로 대체될 것으로 판단된다. 따라서, 청정 발전 시스템의 보급 확대와 기존 에너지의 효율적 사용을 위해서 2차전지 기반의 전력저장 기술과 연료전지 기반의 분산발전 기술이 향후 미래에너지 산업의 근간이 되는 중요한 기술들로 부상하게 되었다. 아연/공기전지는 현재는 연료전지 개념의 1차전지에 기술수준이 머물러 있지만 향후 미래에는 기존의 리튬이온전지의 낮은 에너지밀도를 극복할 수 있는 미래 2차전지 기술의 하나로 평가받고 있다. 본 연구에서는 이러한 연료전지 개념의 아연/공기전지에 대하여 기존의 수소연료전지 기반의 분산발전 분야에 적용한다면 약 1/10 이하의 가격으로 조기에 시장진입이 가능할 것으로 판단하여 사전 타당성 연구 및 대면적화를 위한 기초 설계인자 연구를 수행하였다. 연구결과, 소형 단전지부터 약 800cm2까지의 대면적 단전지까지 대면적화를 위한 기초연구를 실시하였으며, 4개의 cell로 구성된 최고출력 90W급 전해질 순환형 미니스택 시스템을 구성하여 발전시스템으로서의 가능성과 문제점 등을 도출하였다. 이러한 시험결과를 바탕으로 25개의 cell로 구성된 약 1kW 급 스택을 설계하여 향후 소형 발전시스템을 제작하고자 하였다.

  • PDF

Design of the Fuel Cell Powered Line-Interactive UPS System (연료전지 시스템을 이용한 Line-Interactive 방식의 무정전 전원 공급 장치의 설계)

  • Choi, Woo-Jin;Jeon, Hee-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.205-212
    • /
    • 2004
  • In this paper the design of a 1-[KVA] fuel cell powered line-interactive UPS system employing modular (fuel cell & DC/DC converter) blocks is proposed. The proposed system employs the two fuel cell modules along with suitable DC/DC converters and these modules share the DC-Link of the DC/AC inverter. A supercapacitor module is also employed to compensate for the instantaneous power fluctuations and to overcome the slow dynamics of the fuel processor. The energy stored in the supercapacitor can also be utilized to handle the overload conditions for a short time period. Due to the absence of batteries, the system satisfies the demand for an environmentally friendly and dean source of the energy. A complete design example illustrating the amount of hydrogen storage required for 1hr power outage, and sizing of supercacpacitor for transient load demand is presented for a 1-[KVA] UPS.

$CO_2$ Transport for CCS Application in Republic of Korea (이산화탄소 포집 및 저장 실용화를 위한 대한민국에서의 이산화탄소 수송)

  • Huh, Cheol;Kang, Seong-Gil;Cho, Mang-Ik
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.18-29
    • /
    • 2010
  • Offshore subsurface storage of $CO_2$ is regarded as one of the most promising options to response severe climate change. Marine geological storage of $CO_2$ is to capture $CO_2$ from major point sources, to transport to the storage sites and to store $CO_2$ into the offshore subsurface geological structure such as the depleted gas reservoir and deep sea saline aquifer. Since 2005, we have developed relevant technologies for marine geological storage of $CO_2$. Those technologies include possible storage site surveys and basic designs for $CO_2$ transport and storage processes. To design a reliable $CO_2$ marine geological storage system, we devised a hypothetical scenario and used a numerical simulation tool to study its detailed processes. The process of transport $CO_2$ from the onshore capture sites to the offshore storage sites can be simulated with a thermodynamic equation of state. Before going to main calculation of process design, we compared and analyzed the relevant equation of states. To evaluate the predictive accuracies of the examined equation of states, we compare the results of numerical calculations with experimental reference data. Up to now, process design for this $CO_2$ marine geological storage has been carried out mainly on pure $CO_2$. Unfortunately the captured $CO_2$ mixture contains many impurities such as $N_2$, $O_2$, Ar, $H_{2}O$, $SO_{\chi}$, $H_{2}S$. A small amount of impurities can change the thermodynamic properties and then significantly affect the compression, purification and transport processes. This paper analyzes the major design parameters that are useful for constructing onshore and offshore $CO_2$ transport systems. On the basis of a parametric study of the hypothetical scenario, we suggest relevant variation ranges for the design parameters, particularly the flow rate, diameter, temperature, and pressure.

Electrochemical Capacitors (전기화학 커패시터)

  • Kim, Jong-Huy
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.36-42
    • /
    • 2007
  • In general, the battery and the(electric) condenser are pictured as electrical energy storage devices. Although there were lots of inventions and utilizations of morden conveniences according to enormous growth of the science and technologies after the Industrial Revolution, a speed of technology development on these devices being closely used in civilized human lives and many electric or electronic systems as a core component are relatively slower to the other fields of technologies. Nevertheless, based on a remarkable progress of the material science and technologies for the last ten years, a new type of electrical energy storage device so called as 'electrochemical capacitors' are being developed and used practically. The electrochemical capacitors exhibit their own characteristics of much enhanced capacitance over the conventional condensers and also distinctively exhibit a longer lift time and higher power capability that the nickel hydrogen batteries and secondary batteries such as lithium ion and polymer batteries does not show up so for. Hence, in this paper, it is intended to introduce a fundamental understanding and updated technology trends on the electrochemical capacitors.

효율적인 Bioventing 공정을 위한 모니터링 시스템 개발

  • 문원재;오영진;왕성환;박태주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.359-361
    • /
    • 2002
  • 국내에서는 1990년대 이후부터 주유소 및 유류저장시설 부근의 토양 및 지하수오염에 관한 법이 제정되었으며 그와 관련된 복원 및 정화 기술개발에 관한 연구가 진행되고 있다. 그 중 미생물학적 대사를 이용하는 생물학적복원기술(Bioremediation)은 유류로 오염된 지역에서 정화 및 복원방법으로 적용되고 있으며 또한 경제적인 대안으로 제시되고 있다. Bioremediation기법중 하나인 bloventing은 운전 및 처리비용의 감소와 효율의 향상적인 측면에서 여러 연구자들에 의해 수행되고 있다. 기존에는 오염토양에 대한 물리ㆍ화학적 분석과 미생물 활성에 미치는 인자의 측정이 주를 이루었다. 그러나, 최근에는 토양 가스내 $CO_2$ $O_2$의 측정ㆍ분석을 통한 분해율 평가와 탄화수소 분해에 대한 경과 및 복원시간을 예측하고자 하는 연구가 이루어지고 있는 중이다. 본 연구의 목표는 유류오염지역을 복원하기 위한 기술 중 생물학적 복원기술(bioremediation)의 하나인 bioventing 기술의 국내 적용가능성을 알아보고 궁극적으로 국내 실정에 적합한 bioventing공법의 개발을 목표로 한다. 이를 위해 lab-scale bioventing process를 이용하여 생부해를 최대화시키고 오염성분의 휘발을 최소화시키는 bioventing system의 최적운전 mode(연속식, 간헐식)를 개발하기 위해 공기공급량과 생분해량, 그리고 휘발되는 탄화수소양과의 관계를 평가하는 연구를 수행하였다.

  • PDF

Liquid-monopropellant Thrusters for the 3-axis Attitude Control of Space Launch Vehicles -Part 1: Performance Characteristics and Application of Liquid-monopropellants (우주발사체 3축 자세제어용 단일액체추진제 추력기 -Part 1: 단일액체추진제의 성능특성 및 활용)

  • Kim, Jeong-Soo;Park, Jeong;Jung, Hun;Kam, Ho-Dong;Lee, Jae-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.175-178
    • /
    • 2011
  • A performance characteristics and application status of liquid-monopropellants used for 3-axis control thrusters are surveyed, in this paper. Hydrogen peroxide was widely used as monopropellant until mid-1960s, but it is rapidly replaced with hydrazine which has better performance of specific impulse, storability, and so on. Hydrazine is mostly employed as a liquid-monopropellant of satellite, interplanetary spacecraft, and space launch vehicle owing to its moderate performance features.

  • PDF

Development of SMH Actuator System Using Hydrogen-Absorbing Alloy (수소저장합금을 이용한 SMH 액추에이터 시스템 개발)

  • Kwon, Tae-Kyu;Hong, Kyung-Ju;Kim, Kyung;Jeon, Won-Suk;Pang, Du-Yeol;Lee, Seong-Cheol;Kim, Nam-Gyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1067-1073
    • /
    • 2007
  • This paper presents development of an special metal hydride(SMH) actuator system using a peltier module. The newly developed simple SMH actuator, consisting of the plated hydrogen-absorbing alloy as a power source, Peltier elements as a heat source and a cylinder with metal bellows as a functioning part, has been developed. The SMH actuator is characterized by its small size, low weight, noiseless operation and a compliance similar to that of human body. A new SMH actuator that uses reversible reactions between the heat energy and mechanical energy of a hydrogen absorbing alloy. It is well known that hydrogen-absorbing alloys can reversibly absorb and desorb a large amount of hydrogen, more than about 1000 times of their own volume. To improve the thermal conductivity of the hydrogen-absorbing alloy, an electro-less copper plating has been carried out. For this purpose, the effects of the electro-less copper plating and the dynamic characteristics of the SMH actuator have been studied. The hydrogen equilibrium pressure increases and hydrogen is desorbed by heating the hydrogen-absorbing alloys, whereas by cooling the alloys, the hydrogen equilibrium pressure decreases and hydrogen is absorbed. The SMH actuator has the characteristic of being light and easy to use. Therefore, it is suitable for medical and rehabilitation applications.