• 제목/요약/키워드: 수산화인회석

검색결과 72건 처리시간 0.026초

백서 두개골 결손부에 동결 건조 동종 탈회골을 단일매식한 경우와 동결 건조 동종 탈회골과 흡수성 수산화인회석을 복합매식한 경우의 강도 및 골형성에 관한 비교 연구 (A COMPARATIVE STUDY ON THE STRENGTH AND THE BONE FORMATION AT THE RATS CALVARIAL DEFECTS OF DFDB GRAFT AND THOSE OF THE COMPOSITE GRAFT WITH DFDB AND RESORBABLE HYDROXYAPATITE)

  • 서영호;임창준;이재일
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권6호
    • /
    • pp.557-564
    • /
    • 2000
  • The bone graft materials can be grossly divided into autogenous bone, allogenic bone, xenogenic bone, and alloplastic material. Much care was given to other bone graft materials away from autogenous bone due to its additional operation for harvesting, delayed resorption and limitation of quantity. Demineralized freeze-dried bone(DFDB) and hydroxyapatite are the representatives of bone graft materials. As resorbable hydroxyapatite is developed in these days, the disadvantage of nonresorbability can be overcome. So we planned to study on the strength and the bone formation at the rats calvarial defects of DFDB graft and those of the composite graft with DFDB and resorbable hydroxyapatite. We used the 16 male rats weighting range from 250 to 300 gram bred under the same environment during same period. After we made the 6mm diameter calvarial defect, we filled the DFDB in 8 rats and DFDB and resorbable hydroxyapatite in another 8 rats. We sacrificed them at the postoperative 1 month and 2 months with the periostium observed. As soon as the specimens were delivered, we measured the compressive forces to break the normal calvarial area and the newly formed bone in calvarial defect area using Instron(Model Autograph $S-2000^{(R)}$, Shimadzu, Japan). The rest of the specimens were stained with H&E(Hematoxylin & Eosin) and evaluated with the light microscope. So we got the following results. 1. In every rats, there was no significant difference between the measured forces of normal bone area and those of the bone graft area. 2. In 1 month, the measured forces at DFDB graft group were higher than those of the DFDB and resorbable hydroxyapatite composite graft group(P<0.05). 3. In 2 months, there was no significant differences between the measured forces of DFDB graft group and those of the DFDB and resorbable hydroxyapatite composite graft group. 4. In lightmicroscopic examination, most of the grafted DFDB were transformed into bone in 1 month and a large numbers of hydroxyapatite crystal were observed in DFDB and resorbable hydroxyapatite composite graft group in 1 month. 5. Both group showed no inflammatory reaction in 1 month. And hydroxyapatite crystals had a tight junction without soft tissue invagination when consolidated with newly formed bone. 6. In both groups, newly formed bone showed the partial bone remodeling and the lamellar bone structures and some of reversal lines were observed in 2 months. From the above results, it is suggested that DFDB and resorbable hydroxyapatite composite graft group had a better resistance to compressive force in early stage than DFDB graft group, but there would be no significant difference between two groups after some period. And it is suggested that the early stage of bone formation procedure of DFDB and resorbable hydroxyapatite composite graft group was slight slower than that of DFDB graft group, but there would be no significant difference between two groups after some period.

  • PDF

Primer와 과산화수소를 함유한 자가 미백 부착대의 미백 효과에 대한 실험실 실험 연구 (In-Vitro Whitening Efficacy of Hydrogen Peroxide Strips with Primer)

  • 김종훈;문교태;김지혜;안재현
    • 치위생과학회지
    • /
    • 제14권2호
    • /
    • pp.191-197
    • /
    • 2014
  • 본 연구는 전문가의 지도 없이 소비자가 쉽게 구매할 수 있는 일반적 치아 미백제에 대한 연구로 과산화수소의 함량제한이 있는 국내 사용 환경에서 보다 효과적인 미백 효능을 제공하고자 동일 과산화수소 함량에서 미백 효과를 증진시켜 줄 수 있는 금속 이온 등을 함유한 primer에 대해 착색시킨 수산화인회석 시편을 이용한 실험실적 방법으로 미백효과를 평가하였다. 평가원료들은 인체 안전성을 고려하여 식품 첨가물 공전에 수재된 원료에서 선별하였으며 금속 이온의 종류 및 염의 종류에 따른 효과를 평가한 결과 3가 철 이온을 방출하는 염화제이철을 함유한 primer를 적용 시 미백 효과가 가장 우수하였다. 여기에 제삼인산칼륨을 사용하여 pH를 알칼리조건으로 만든 pH 10.0 primer를 적용 시 더욱 미백 효과가 증가됨을 확인하였으며 primer를 사용하지 않은 대조군과 시간에 따른 미백 효과를 비교한 결과 30분 부착 시 1.75배의 명도 변화량을 나타내었다. 본 연구는 인공 재료와 인공적 실험 환경에서 이뤄진 실험실적 연구로서 실제 인체에 적용 시 안전성이나 부수적 효과에 대해서는 추후 추가적으로 평가해야 할 필요가 있으나 제한된 과산화수소 함량에서 primer의 사용으로 미백 효과를 극대화할 수 있다는 것을 확인하였다는 점에서 의미가 있다고 생각된다.

수산화인회석과 인산삼칼슘 및 1형 콜라젠 혼합골의 전자빔 조사 효과 (Effect of Electron-beam Irradiaton on the Artificial Bone Substitutes Composed of Hydroxyapatite and Tricalcium Phosphate Mixtures with Type I Collagen)

  • 박정민;김성민;김민근;박영욱;명훈;이병철;이종호;이석근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권1호
    • /
    • pp.38-50
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the effect and potential of electron beam (E-beam) irradiation treatment to the synthetic bony mixtures composed of hydroxyapatite (HA; Bongros$^{(R)}$, Bio@ Co., Korea) and tricalcium phosphate (${\beta}$-TCP, Sigma-Aldrich Co., USA), mixed at various ratios and of type I collagen (Rat tail, BD Biosciences Co., Sweden) as an organic matrix. Methods: We used 1.0~2.0 MeV linear accelerator and 2.0 MeV superconductive linear accelerator (power 100 KW, pressure 115 kPa, temperature $-30{\sim}120^{\circ}C$, sensor sensitivity 0.1~1.2 mV/kPa, generating power sensitivity 44.75 mV/kPa, supply voltage $5{\pm}0.25$ V) with different irradiation dose, such as 1, 30 and 60 kGy. Structural changes in this synthetic bone material were studied in vitro, by scanning electron microscopy (SEM), elementary analysis and field emission scanning electron microscope (FE-SEM), attenuated total reflection (ATR), and electron spectroscopy for chemical analysis (ESCA). Results: The large particular size of HA was changed after E-beam irradiation, to which small particle of TCP was engaged with organic collagen components in SEM findings. Conclusion: The important new in vitro data to be applicable as the substitutes of artificial bone materials in dental and medical fields will be able to be summarized.

의도적으로 연조직에 노출시킨 수산화인회석 코팅 임플란트의 골유착과 안정성에 대한 실험적 연구 (Experimental Study of Osseointegration and Stability of Intentionally Exposed Hydroxyapatite Coating Implants)

  • 정경인;김수관;문성용;오지수;조지호;임형섭;김정선;임성철;정미애
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권1호
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose: The purpose of this study is to evaluate the effect of exposure of hydroxyapatite coating on the amount of bone formation and stability in the dogs. Methods: In this study, hydroxyapatite coated implants (HAPTITE) was placed over the femur bone surface of four dogs about 1 mm. The experimental group was divided into 4 weeks group of 8 implants and 8 weeks group of 8 implants, and then they were sacrificed. The stability of implants was evaluated twice with Osstell$^{TM}$ mentor (Osstell AB, Goteborg, Sweden) at right after placement and sacrifice. The amount of bone formation was evaluated through histomorphometric examination. Results: The stability of implants was in normal range, and tended to increase as time goes by. Mean percentages of new bone formation rates were $90.5{\pm}6.6$ at uppermost 1 mm bone level adjacent to soft tissues (level 1) and $92.9{\pm}4.1$ at next 1 mm bone level (level 2) in 4 weeks group, $90.1{\pm}11.5$ at level 1 and $95.9{\pm}2.3$ at level 2 in 8 weeks group. Mean percentages of bone-implant contact rates were $85.1{\pm}10.8$ at level 1 and $88.1{\pm}13.8$ at level 2 in 4 weeks group, $88.5{\pm}14.4$ at level 1 and $95.3{\pm}3.1$ at level 2 in 8 weeks group. There was no statistically significant difference of new bone formation rate and bone-implant contact rate between uppermost 1 mm bone level adjacent to soft tissues and next 1 mm bone level. However, there was no significant difference in bone formation between 4 and 8 weeks groups. Conclusion: These results suggested that exposed hydroxyapatite coated implants to soft tissue showed favorable bone formation and implant stability.

가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구 (Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits)

  • 김상수;이주형;유석현;이형주;문지원;박인숙;손동석
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

pH 4.3과 pH 7.0의 과포화용액에서 불소의 농도가 합성 수산화인회석의 결정 성장에 미치는 영향 (Effect of fluoride concentration in pH 4.3 and pH 7.0 supersaturated solutions on the crystal growth of hydroxyapatite)

  • 신한얼;박성호;박정원;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제37권1호
    • /
    • pp.16-23
    • /
    • 2012
  • Objectives: Present study was undertaken to investigate the crystal growth onto synthetic hydroxyapatite (HA) seeds in pH 4.3 and pH 7.0 supersaturated solutions with different fluoride concentrations. Materials and Methods: 8 groups of pH 4.3 and 7.0 calcium phosphate supersaturated solutions were prepared with different fluoride concentrations (0, 1, 2 and 4 ppm). Calcium phosphate precipitates yield crystal growth onto the HA seed surface while solutions flow. For evaluation of crystallizing process, the changes of $Ca^{2+}$, $PO{_4}^{3-}$, $F^-$ concentrations of the inlet and outlet solutions were determined. The recovered solid samples were weighed to assess the amount of minerals precipitated, and finally determined their composition to deduce characteristics of crystals. Results: During the seeded crystal growth, there were significantly more consumption of $Ca^{2+}$, $PO{_4}^{3-}$, $F^-$ in pH 4.3 solutions than pH 7.0 (p < 0.05). As fluoride concentration increased in pH 4.3 solution, $Ca^{2+}$, $PO{_4}^{3-}$, $F^-$ consumption in experimental solutions, weight increment of HA seed, and fluoride ratio in crystallized samples were increased. There were significant differences among the groups (p < 0.05). But in pH 7.0 solution, these phenomena were not significant. In pH 7.0 solutions, analyses of crystallized samples showed higher Ca/P ratio in higher fluoride concentration. There were significant differences among the groups (p < 0.05). But in pH 4.3 solution, there were not significant differences in Ca/P ratio. Conclusions: Crystal growth in pH 4.3 solutions was superior to that in pH 7.0 solutions. In pH 4.3 solutions, crystal growth increased with showed in higher fluoride concentration up to 4 ppm.

수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교 (Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant)

  • 임형섭;김수관;오지수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권2호
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.

민감성 치아에 대한 수산화인회석 함유 치약의 임상적 효과 (The clinical effects of a hydroxyapatite containing toothpaste for dentine hypersensitivity)

  • 김수환;박준범;이철우;구기태;김태일;설양조;이용무;구영;정종평;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.87-94
    • /
    • 2009
  • Purpose: The aim of this study was to compare the effectiveness of hydroxyapatite containing toothpaste with positive control toothpastes in reducing dentine hypersensitivity. Materials and methods: This clinical trial was a double-blind, randomized, parallel group comparison of two, namely hydroxyapatite containing toothpaste and strontium chloride containing toothpaste. A total of 55 subjects were included in this study. The subjects were given randomly assigned one of the two toothpastes after received tooth brushing instruction at baseline. Some clinical indices(PI, GI, PD), verbal rating score(VRS) for sensitivity to stimulus, the effect in relieving sensitivity and visual analogue scale(VAS) for sensitivity at baseline, week 2, week 4 and week 8 were assessed. All data were evaluated by intention-to-treat analysis. Results: Overall, PI and GI scores were significantly reduced compare baseline in all groups(p<0.05). In addition, there was significant difference in PI at 4 weeks and in GI at 4, 8 weeks between groups. The proportions of subjects relieved sensitivity were 70.4% in experimental group and 57.1% in control group at 8 weeks respectively. The VRS for sensitivity to three kinds of stimuli and VAS for sensitivity decreased according to time, there was no overall difference between two groups(p>0.05). Conclusion: This study demonstrated that the new hydroxyapatite containing toothpaste was similarly effective in reducing dentine hypersensitivity with pre-existing benchmark toothpaste.

Resorbable blasting media 및 산처리한 임플란트의 제거회전력에 생리식염수를 적시는 것이 미치는 영향 (On the effect of saline immersion to the removal torque for resorbable blasting media and acid treated implants)

  • 권재욱;조성암
    • 구강회복응용과학지
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2018
  • 목적: Resorbable blasting media (RBM) 표면처리 후 산처리한 티타늄 임플란트와 동일한 표면처리 후 생리식염수에 적신 티타늄 임플란트에서 생리식염수에 적신 경우 초기 골유착에 미치는 영향을 제거회전력 및 표면분석을 통해서 알아보고자 하였다. 연구 재료 및 방법: 대조군은 RBM 표면처리 후 산처리된 임플란트(RBM + HCl)이고, 실험군은 대조군과 동일한 표면처리 후 생리식염수에 2주간 적신 임플란트(RBM + HCl + Sal)이다. 토끼 10마리의 좌우측 경골에 각각 대조군 및 실험군 임플란트를 식립하고, 동시에 식립회전력(ITQ)을 측정하였다. 10일 후 임플란트 식립부위를 노출시켜 제거회전력(RTQ)을 측정하였다. 실험에 사용된 임플란트 시편의 표면분석을 위해 field emission-scanning electron microscopy (FESEM), energy dispersive X-ray Spectroscopy (EDS), 표면거칠기 측정 및 Raman 분광분석을 시행하였다. 결과: RBM 표면처리 및 산처리하여 생리식염수에 적신 티타늄 임플란트에서 대조군에 비해 높은 제거회전력을 나타냈으며, 통계적으로 유의미한 값을 보였다(P = 0.014 < 0.05). 표면거칠기는 실험군에서 더 높은 거칠기를 나타냈다. 결론: 티타늄 임플란트에 RBM 표면처리 및 산처리 후 생리식염수에 적신 것이 생리식염수를 적시지 않은 것 보다 초기 골유착을 향상시키는 것으로 생각된다.

골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구 (Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration)

  • 황갑운
    • 한국융합학회논문지
    • /
    • 제12권12호
    • /
    • pp.145-151
    • /
    • 2021
  • Ti Gr4에 TPS 법을 이용하여 HA 코팅을 수행하여 코팅층에 대한 물리적특성 및 생체적합성을 판단하여 의료용 부품으로서의 활용성에 대한 평가를 하였다. 직경 25mm Ti Gr4 합금 시험편을 기계가공 후 #120, #400, #1,000 샌드페이퍼 및 바렐 연마로 표면을 연마를 하여 ASTM F1185-88로 HA 코팅은 한 후 HA 코팅층의 두께, 표면조도, 강도 및 접착력 측정 시험과 세포독성 시험을 하였다. Ti Gr4에 대한 HA 코팅 결정도는 75.51%, Ca/P 비는 1.67의 값을 얻을 수 있었다. HA 코팅층의 두께는 Ti 소재의 표면거칠기가 거칠수록 증가하고, 코팅의 강도 및 접착력은 시험장치의 지그 형상, 에폭시 성분, 크로스헤드 속도 등에 따라 변화가 있을 것으로 예측된다. 세포독성 시험은 Grade 3의 반응성으로 적합한 것으로 나타났다. 본 실험 결과 TPS에 의한 Ti Gr4 소재의 HA 코팅 두께 향상과 골융합을 촉진이 가능할 것으로 확인되어 인체삽입용으로 상용화가 가능할 것으로 판단된다.