• Title/Summary/Keyword: 수복재료

Search Result 321, Processing Time 0.024 seconds

THE EFFECT OF 1.23% APF GEL ON THE ESTHETIC RESTORATIVE MATERIALS (APF Gel이 심미 수복재료의 표면에 미치는 영향)

  • Choi, Won-Hyuk;Kim, Eun-Jung;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.281-289
    • /
    • 2006
  • Topical fluoride application for children is a widely performed procedure in the field of Pediatric Dentistry for its dental caries prevention effects However, it is recently recognized as having some unwanted effects on several esthetic restorative materials, the author immersed glass ionomer cement, compomer and composite resin specimens in APF gel and measured the surface roughness and also, examined the specimens under the scanning eletron microscope. The followings are the results: 1. In the specimens of glass ionomer cement and compomer, APF gel 4 minute immersion group and pH cycling group show statistically significant increased surface roughness than artificial saliva immersion group (p<0.01). 2. There was no statistically significant surface roughness for composite resin in all group (p>0.05). 3. When the specimens were examined under scanning electron microscope, the surface change were in the order of glass ionomer cement, compomer, composite resin and also in the order of pH cycling group, APF gel 4 minutes immersion group, artificial saliva immersion group.

  • PDF

SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS (Ormocer 계열 수복재의 물성에 관한 연구)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.362-370
    • /
    • 2002
  • During the last two decades, many new filling materials and material groups have been developed. the number of available restoratives has increased dramatically, especially during the last 5 years. Ormocers are a new class of materials which are still under development with regard to dental applications. However, in the chemical literature these materials have been known for a long time and used for producing scratch resistant coatings on plastic spectacle lenses. It is a combination of inorganic and organic materials. 'Ormocer' is an abbreviation for 'Organically Modified Ceramics'. These compounds are also known in the literature as 'Ormosils' (organically modified silicates). Their chemistry is comparable to that of silicones and organic polymers. The purpose of this study was to determine of compressive strength and flexural strength of a ormocer (Admira) and to investigate the effects of water absorption in comparison with three composite resins(Z-100, Tetric Ceram, Surefil) and one compomer(Dyract AP). The following results were obtained ; 1. Admira had the lower compressive strength than Surefil, but no statistically difference with other materials at 1 day(p>0.05). 2. Admira had the lower flexural strength than all other materials at 1 day. From 2 days, Admits showed lower flexural strength than three composite resin(p<0.05). 3. There was not statistically significant difference of compressive and flexural strengths between hybrid composite resin group(Z-100, Tetric Ceram) and Packable resin group(Surefil) for experimental period(30 days)(p>0.05). 4. All five materials showed an increase in compressive and flexural strength till 2 days and showed a decrease from 7 days in water(p<0.05). 5. Each materials had the statistically similar behavior of compressive and flexural strengths over time(p>0.05).

  • PDF

Osseointegration of Ceramics & Zirconia : A Review of Literature (세라믹과 지르코니아의 골유착에 관한 고찰)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.319-326
    • /
    • 2012
  • For many years, ceramics have been used in fixed prosthodontics for achieving optimal esthetics. but, they have another use as well. Many studies today show ceramics can be used for biomaterials. In the beginning researchers made a start in the study of aluminium oxide and sapphire for biomaterial. The appearance of Zirconia began a new phase of research. Zirconia was introduced into implantology as an alternative to titanium, because of its white color, good mechanical properties and superior biocompatibility. But it is not easy to surface treatment in comparison with titanium. To overcome the limitation, interconnected porous bodies of zirconia were fabricated by sintering technique. And the technique of coating was developed. Therefore, some zirconia implants are currently available. It is thought that Research of biomaterials as a variety of puposes for the use of zirconia is looking very promising. The purpose of this paper reviews are to evaluation of zirconia as biomaterials.

Microleakage at the cervical margin of Class II composite restorations with different intermediate layer treatments (치경부변연에서 중간층 수복이 구치부 2급 복합레진의 미세누출에 미치는 영향에 관한 연구)

  • Kim, Ki-Ok
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.467-474
    • /
    • 2003
  • 복합레진에 의한 구치부 2급 와동의 수복에서 치은부 변연이 법랑-백아 경계 하방에 위치하는 경우 복합레진의 중합 수축에 의한 응력은 변연부의 폐쇄능력을 저하시키고 이로인한 미세누출은 2차적인 우식이나 술후과민증을 일으켜 임상에서의 성공을 위협한다. 본 연구에서는 2급 와동에서 복합레진으로 수복하기 전에 치은 변연부를 중합수축에 의한 응력을 완화시킬 수 있는 것으로 알려진 몇가지 재료들을 중간층으로 먼저 충전한 후 충전용 복합레진으로 충전한 뒤 치은부 변연에서 이들 중간층과 치질 사이의 미세누출의 정도를 비교하였다. 20개의 발거된 구치의 근, 원심면에 각각 상자 모양의 2급 와동을 형성하고 40개의 와동을 무작위로 10개씩, 4개의군으로 나누었다. 1군은 중간층의 수복없이 Clearfil SE Bond과 Clearfil AP-X로 충전하였으며 2, 3 및 4군은 중간층으로 각각 Revolution, Dyract그리고 FujiII LG를 먼저 충전한 후 1군과 동일한 방법으로 복합레진을 충전하였다. 충전된 시편은 열순환후 2% methylene blue 용액에 12시간 침잠시킨 후 색소의 침투도를 stereomicroscope로 관찰하였으며 실험결과는 Kruskal-Wallis non-parametric independent analysis 및 Mann-Whitney U test로 통계분석하여 다음의 결론을 얻었다. 1. 레진강화형 글라스아이오노머를 중간층으로 먼저 수복하고 복합레진으로 충전한 경우에서 더 적은 미세누출을 보였다(p<0.05). 2. 유동성 레진과 콤포머를 중간층으로 수복한 경우와 복합레진만으로 수복한 경우는 미세누출에 있어서 유의한 차이를 나타내지 않았다(p>0.05).

CHARACTERISTICS OF FLUORIDE RELEASING RESTORATIVE MATERIALS AFTER TOOTHBRUSH-DENTIFRICE ABRASION (잇솔질 마모 처리한 불소방출성 수복재의 특성)

  • Park, Jong-Ha;Baik, Byeong-Ju;Yang, Yeon-Mi;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.705-713
    • /
    • 2004
  • The objectives of this study were to evaluate the fluoride release and the change of surface roughness of fluoride releasing restorative materials after toothbrush-dentifrice abrasion. Seven commercially available fluoride releasing restorative materials (Fuji II LC Improved: FL, Compoglass F: CG, Dyract AP: DR, F2000: FT, Ariston: AT, Tetric: TR, and Gradia: GD) were selected as experimental materials. The results obtained were summarized as follows: 1. The AT, FL, and CF groups produce an initially large burst of fluoride release and comparatively low but continuous release of fluoride. But other groups produce no initial burst of fluoride and levels of release remain relatively constant. 2. The rate of fluoride release remains steady state after 40 days. The results of Tukey's test (P<.05), the fluoride release showed the order of decreasing rank as follows: AT > FL > compomers > TC and GD. 3. The surface roughness indicated that the highest value was observed in the FT group and the lowest value was observed in the CF group. The surface roughness of Tukey's test showed the significant differences between groups of FT, AT and FL and groups of CF, DR, GD and TC (P<0.05).

  • PDF

EFFECT OF RESTORATION TYPE ON THE STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY PREMOLARS; THREE-DIMENSIONAL FINITE ELEMENT STUDY (수복물의 종류가 근관치료된 상악 제2소구치의 응력분포에 미치는 영향: 3차원 유한요소법적 연구)

  • Jung, Heun-Sook;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.8-19
    • /
    • 2009
  • The purpose of this study was to investigate the effects of four restorative materials under various occlusal loading conditions on the stress distribution at the CEJ of buccal. palatal surface and central groove of occlusal surface of endodontically treated maxillary second premolar, using a 3D finte element analysis. A 3D finite element model of human maxillary second premolar was endodontically treated. After endodontic treatment, access cavity was filled with Amalgam, resin, ceramic or gold of different mechanical properties. A static 500N forces were applied at the buccal (Load-1) and palatal cusp (Load-2) and a static 170N forces were applied at the mesial marginal ridge and palatal cusp simultaneously as centric occlusion (Load-3). Under 3-type Loading condition, the value of tensile stress was analyzed after 4-type restoration at the CEJ of buccal and palatal surface and central groove of occlusal surface Excessive high tensile stresses were observed along the palatal CEJ in Load-1 case and buccal CEJ in Load-2 in all of the restorations. There was no difference in magnitude of stress in relation to the type of restorations. Heavy tensile stress concentrations were observed around the loading point and along the central groove of occlusal surface in all of the restorations. There was slight difference in magnitude of stress between different types of restorations. High tensile stress concentrations around the loading points were observed and there was no difference in magnitude of stress between different types of restorations in Load-3.

The influence of combining composite resins with different elastic modulus on the stress distribution of class V restoration: A three-dimensional finite element study (탄성계수가 다른 복합레진의 혼합수복이 5급 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Jeong-Kil;Hur, Bock;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.184-197
    • /
    • 2008
  • This study was to investigate the influence of combining composite resins with different elastic modulus, and occlusal loading condition on the stress distribution of restored notch-shaped non-carious cervical lesion using 3D finite element (FE) analysis. The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. A notch-shaped cavity was modeled and filled with hybrid, flowable resin or a combination of both. After restoration, a static load of 500N was applied in a point-load condition at buccal cusp and palatal cusp. The stress data were analyzed using analysis of principal stress. Results showed that combining method such that apex was restored by material with high elastic modulus and the occlusal and cervical cavosurface margin by small amount of material with low elastic modulus was the most profitable method in the view of tensile stress that was considered as the dominant factor jeopardizing the restoration durability and promoting the lesion progression.

  • PDF

The influence of combining composite resins with different elastic modulus on the stress distribution of class V restoration: A three-dimensional finite element study (탄성계수가 다른 복합레진의 혼합수복이 5급 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Jeong-Kil;Hur, Bock;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.184-197
    • /
    • 2008
  • This study was to investigate the influence of combining composite resins with different elastic modulus, and occlusal loading condition on the stress distribution of restored notch-shaped non-carious cervical lesion using 3D finite element (FE) analysis. The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. A notch-shaped cavity was modeled and filled with hybrid, flowable resin or a combination of both. After restoration, a static load of 500N was applied in a point-load condition at buccal cusp and palatal cusp. The stress data were analyzed using analysis of principal stress. Results showed that combining method such that apex was restored by material with high elastic modulus and the occlusal and cervical cavosurface margin by small amount of material with low elastic modulus was the most profitable method in the view of tensile stress that was considered as the dominant factor jeopardizing the restoration durability and promoting the lesion progression.

Composite Resin의 Modern Cavity form

  • Park, Sang-Jin
    • The Journal of the Korean dental association
    • /
    • v.26 no.8 s.231
    • /
    • pp.693-699
    • /
    • 1988
  • Composite Resin(콤포짓트 레진) 수복은 3급,4급(견치의 원심면 제외) 및 5등급 전치부와동에 주로 사용되었으나 재료의 개선으로 인해 1급,2급 및 견치 3급와동의 원심면에도 제한적으로 사용이 가능하게 되었다. 물론 실제적인 와동의 설계는 수복요건에 따라 다양한 형태변화를 부여할 수도 있다.

  • PDF

The effect of acidic drinks on the surface of tooth-colored restorative materials (산성음료가 치아색 수복재의 표면에 미치는 영향)

  • Bang, Seok-Yun;Kim, Eun-Jung;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.469-481
    • /
    • 2006
  • Among the etiologic factors of enamel corrosion, daily intake has been considered with a profound interest, especially the intake of acidic drinks. It is thought that the rapid consumption of acidic drinks will not only results in the affection to the teeth but also to the surface of the tooth-colored restorative materials. Therefore, the puopose of this study is to examine the alterations occurred in the surface of the tooth-colored materials according to the exposed time, with 3 most common acidic drinks in contact with daily life. Resin-modified glass-ionomer, polyacid-modified composite resin, composite resin were immersed on 0.9% NaCl, Coke, orange juice, sports beverages as 4 groups in each. The surface hardness and the surface roughness of specimens were measured with following methods: before immersion, 1 day after immersion, 1-,2-,3-,4- weeks after immersion. Results were as follows. 1. Tooth-colored restorative materials, with the exception of composite resin, showed statistically significant changes in surface hardness and roughness when immersed on acidic drinks(p<0.05). 2. The degree of change in surface hardness and roughness occurred as follows, in order of severity from greatest to least resin-modified glass-ionomer, polyacid-modified composite resin, composite resin 3. Sports beverages resulted in greater alterations to surfaces than Coke and orange juice. 4. In the SEM image of the groups immersed in acidic drinks, resin-modified glass-ionomer and polyacid-modified composite resin showed loss of filer. Severe cracks were observed, especially on the resin-modified glass-ionomer.

  • PDF