• Title/Summary/Keyword: 수리저항성능

Search Result 14, Processing Time 0.036 seconds

Relationship between Electrical Resistivity and Hydraulic Resistance Capacity measured by Rotating Cylinder Test (회전식 수리저항성능 실험기를 이용한 지반의 수리저항특성과 전기비저항 특성의 상관관계)

  • Kim, Young Sang;Jeong, Shin Hyun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Recently, constructions of coastal structure including wind turbine structure have increased at southwest shore of Korea. There is a big difference of tide which rage from 3.0 m to 8.0 m at south and wet shore of Korea, respectively. In such ocean circumstance, large scour may occur due to multi-directional tidal current and transverse stress of the wind. therefore scour surrounding wind turbine structure can make system unsafe due to unexpected system vibration. In this study, hydraulic resistance capacity, i.e., critical velocity and critical shear stress, was evaluated by RCT. Uni-directional and bi-directional hydraulic resistance capacities of the samples which were consolidated by different preconsolidation pressures were correlated with soil resistivities of same samples. According to the correlation, it is possible to estimate hydraulic resistance capacity from electrical resistivity of soil. Through the updating the correlation for various soil types, it is expected that the hydraulic resistance capacity of whole construction site will be simply determined from the electrical resistivity.

Effect of Incidence Angle of Current on the Hydraulic Resistance Capacity of Clayey Soil (흐름의 입사각이 점성토 지반의 수리저항성능에 미치는 영향)

  • Kim, Young-Sang;Han, Byung-Duck;Kang, Gyeong-O
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.26-35
    • /
    • 2012
  • Until now, study on the hydraulic resistance characteristics of the ground at the river and the ocean current has been focused on the behavior under uni-directional flow without the direction change of flow. However, recent research result shows that scour rate which were measured under the bi-directional flow was much higher than those measured under uni-directional flow for both fine grained and coarse soil. Since the direction of inflow and return flow at the shore, where the structure will be constructed, is not always $180^{\circ}$, effect of the incidence angle on the hydraulic resistance capacity of the ground should be examined. Using the improved EFA which can consider the direction change of flow, hydraulic resistance capacities of the artificially composed clayey fine grained soil and clayey sandy soil under $0^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$ flow angle of incidence were assessed. Test result shows that hydraulic resistance capacity decreases and scour rate increase with the increase of the incidence angle between inflow and return flow. For the low consolidation pressure condition, hydraulic resistance capacity of the fine grained soil decreases rapidly. While the hydraulic resistance capacity of the coarse grained soil decreases more rapidly than fine grained soil under high consolidation pressure. Eventually since the larger the incidence angle between inflow and return flow, the larger the scour rate. Hydraulic resistance capacity under bi-directional flow($0^{\circ}{\longleftrightarrow}180^{\circ}$) should be examined for the design purpose.

Effects of Flow Direction and Consolidation Pressure on Hydraulic Resistance Capacity of Soils (흐름방향과 압밀응력이 지반의 수리저항특성에 미치는 영향)

  • Kim, Youngsang;Jeong, Shinhyun;Lee, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.5
    • /
    • pp.55-66
    • /
    • 2015
  • Big tidal differences, which range from 3.0 m to 8.0 m, exist with regional locations at south and west shores of Korea. Under this ocean circumstance, since a large scour may occur due to multi-directional tidal current and transverse stress of the wind, the scour surrounding the wind turbine structure can make instability of the system due to unexpected system vibration. The hydraulic resistance capacity of soils consolidated under different pressures are evaluated by Erosion Function Apparatus (EFA) under unidirectional and bi-directional flows in this study. It was found that the flow direction change affects significantly on the sour rate and critical shear stress, regardless of soil types while the consolidation pressure affects mainly cohesive soil. Among geotechnical parameters, the undrained shear strength can be well-correlated with the hydraulic resistance capacity, regardless soil type while the shear wave velocity shows the proportional relationships with the hydraulic resistance capacities of fine grained soil and coarse grained soil, respectively.

Performance Evaluation of Revetment Method Using Bio-polymer (바이오 폴리머를 이용한 호안 공법의 성능 평가)

  • Kim, Myounghwan;Lee, Du Han;Lee, Kang-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.224-224
    • /
    • 2020
  • 새롭게 개발된 미생물의 부산물인 바이오 폴리머는 토양의 강도를 높이고, 식물의 생장을 촉진시킨다. 본 연구에서는 실규모 수리 실험을 수행하여 바이오 폴리머를 이용한 호안 공법의 침식 저항 성능을 평가하였다. 실험을 위하여 다수의 호안 공법 시험체를 제작하였고, 이 시험체를 실 규모 실험수로에 설치하고 수리 실험을 통해 토양 손실과 이에 따른 한계 소류력을 결정하였다. 실험에는 일반 흙을 피복한 시험체, 바이오 폴리머와 혼합한 흙을 피복한 시험체, 식생매트와 바이오 폴리머 혼합토를 결합한 시험체 등이 사용되었다. 실험결과 재료나 식생의 활착도에 따른 차이는 있었으나 바이오 폴리머를 이용한 시험체의 침식 저항 성능이 바이오 폴리머를 이용하지 않은 시험체에 비해 높게 나타나는 것은 일관되게 확인 할 수 있었다. 이러한 결과는 바이오 폴리머를 이용한 호안공법이 기존 호안 공법의 침식 저항성능을 향상 시킬 수 있음을 보여준다. 바이오 폴리머를 제방 호안 시공에 활용한다면 홍수로 인한 제방의 유실이나 파괴를 상당 부분 예방할 수 있을 것이다.

  • PDF

Experimental Study on Hydraulic Resistance of Sea Ground Considering Tidal Current Flow (왕복류 흐름을 고려한 지반의 수리저항성능 실험)

  • Kim, Young-Sang;Gang, Gyeong-O
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.118-125
    • /
    • 2011
  • Conventional erosion function apparatus (EFA) which has been used to measure the hydraulic resistance of soil was improved to consider direction change of the current flow. Using improved apparatus, hydraulic resistance capacities of the artificially composed clayey soil and sandy soil were compared. Test result shows that scour rates which were measured under the bi-directional flow were much higher than those measured under unidirectional flow for both type soils. Scour rate of sandy soil was higher than that of clayey soil. Velocity averaged scour rate of specimen which was consolidated under the relatively large consolidation pressure is higher than that of specimen which is consolidated under small consolidation pressure, which means scour problem under bidirectional flow may be more serious for the deep seabed ground.

Real-Scale Hydraulic Experiment of Planted Vegetation Mats (식생이 활착된 식생매트의 실규모 수리 실험)

  • Lee, Du Han;Kim, Myounghwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.368-368
    • /
    • 2015
  • 본 연구에서는 식생이 활착된 식생매트 제품의 유속 저항 성능을 평가하기 위하여 식생매트의 설치 및 식생의 활착이 가능한 이동식 bed를 개발하고, 개발된 이동식 bed에서 식생매트 설치 및 식생의 활착을 완료한 후, 이동식 bed를 폭 11m 규모의 수로에 설치하여 실규모의 수리 실험을 수행하였다. 실험을 위하여 미국의 식생매트 제품의 시험방법인 ASTM D 6460을 참고하였다. 실험에 사용된 식생매트는 국내에서 통상적으로 사용되는 야자섬유 매트를 사용하였으며, 식생매트의 식생은 토심이 얕은 이동식 bed의 생육환경에서도 뿌리가 잘 발달할 수 있는 수크령을 선택하여 활착시켜 사용하였다. 실험은 봄 활착 및 가을 활착 두 가지 조건에 대하여 수행하였으며, 두 실험 조건의 결과 비교를 통하여 식생매트의 계절에 따른 식생활착 특성과 유속저항 성능 차이를 확인하였다.

  • PDF

A Study on the Erosion Resistance Performance of Biopolymer Mixed Soils According to Soil Types (토양 종류에 따른 바이오폴리머 혼합토의 침식저항 성능 연구)

  • Kim, Myounghwan;Lee, Du Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.221-221
    • /
    • 2021
  • 토양의 강도와 점성을 높여주는 바이오폴리머를 제방 호안에 도포하면 기존의 다른 호안 재료들과 마찬가지로 제방을 보호하는 것이 가능하다. 특히 바이오폴리머는 천연 토양과 혼합하여 사용하므로 다른 인공적인 호안재료들에 비해 생태적으로 유리하다. 하지만 바이오폴리머는 결합되어지는 토양의 점도, 공극률, 입도 등의 토양이 가지는 특성에 따라 성능이 변화하기 때문에 바이오폴리머를 이용한 혼한토를 제방 호안에 적용하기 위해서는 적절한 강도를 가지게 하는 토양을 선정해야 한다. 본 연구에서는 바이오폴리머를 마사토 및 황토 등과 결합하여 시험구를 설치하고 식생환경을 조성한 뒤 실규모 실험수로에서 수리 실험을 수행하여 바이오폴리머를 이용한 호안 공법의 침식 저항 성능을 평가하고 토양의 종류에 따라 성능을 비교하였다.

  • PDF

Hydraulic Resistance Characteristics of Compacted Weathered Granite Soil by Rotating Cylinder Test and Image Analysis (영상처리기법과 회전식 수리저항성능 실험을 이용한 다짐화강풍화토의 수리저항특성 분석)

  • Kim, Young Sang;Lim, Jae Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.25-34
    • /
    • 2016
  • Recently, in Korea, problems related with unstability of slope or sinkhole in urban area due to erosion of compacted granite soil which was used as a backfill or embankment material have been treated as important issues. Small hole might develop inside of backfill area due to erosion of not only weathered granite soil but also clay, silt, fine sand size particles when underground water flows. Once erosion starts in a soil mass, erosion rate increases gradually to cause rapid destruction. In this study, a rotating cylinder test (RCT) was performed to evaluate the hydraulic resistance characteristics of compacted weathered granite soil under various relative densities and preconsolidation pressures. Meanwhile, an image analysis method was introduced to analyze radius of irregularly eroded sample. It was found that image analysis is an effective means of minimizing the error in calculating a critical shear stress and threshold shear stress on the irregularly eroded sample. Furthermore, in general, hydraulic resistance capacity increases with the increase of relative density and preconsolidation pressure.

Imaging of Fractures and Tunnel by 3-D ERT (전기비저항 토모그래피에 의한 파쇄대 및 터널의 3차원 영상화)

  • Yi, Myeong-Jong;Kim, Jung-Ho;Son, Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.302-309
    • /
    • 2008
  • ERT imaging, especially 3-D method, is a very powerful means to obtain a very high resolution image of the subsurface for geotechnical or hydrogeological problems. In this paper, we introduce two examples of successful case histories, where the imaging targets were three-dimensional. First example is the case of 3-D fracture imaging for hydrogeologic application. In this example, the borehole deviation was a critical problem in the ERT imaging and we could obtain real 3-D attitude of fracture system by including the borehole deviation in the inversion. In the second case, we did field experiment to image the empty tunnel with the size of $2m{\times}2m$ and the target was very clearly imaged in 3-D space. In these examples, we could show that 3-D ERT imaging is a very powerful tool for the 3-D subsurface imaging and the method can provide enhanced imaging capabilities especially for the 3-D targets such as fractures and cavities or tunnel.

Development of Apparatus for Measuring Hydraulic Resistance of Sea Ground Considering Tidal Current Flow (조류 흐름을 고려한 해양지반 수리저항성능 실험기 개발)

  • Kang, Kyoung-O;Jeong, Hyun-Chel;Kim, Young-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1366-1369
    • /
    • 2010
  • Along with the increasing need of sea development, the hydraulic stability of seabed structure on a soft seafloor ground is becoming an issue in the course of seaside development recently. However, the movement and hydraulic resistance or hydraulic stability of seafloor ground are mutually coupled with various phenomena, and there has been no clear proof for the issue, which makes it difficult to forecast. Furthermore, most researches are focused on hydraulic variables and the conditions of marine external force, while there have been few researches into the assessment in consideration of the type of a seafloor ground and the geotechnical characteristics. In addition, according to the periodic change of the flow direction, possible changes in hydraulic resistance performance of the seafloor deserves all the recognition. But there is no way to measure the hydraulic unstability of the sea ground due to tidal flow quantitatively. In this study, conventional hydraulic resistance measurement apparatus was improved to consider direction change of the current flow. Various artificial clayey soil specimens were made from Kaolinite and Jumunjin standard sand and hydraulic resistance tests were performed by changing the flow direction to validate the effect of the direction change on the scour of the seafloor.

  • PDF