• Title/Summary/Keyword: 수로

Search Result 354,934, Processing Time 0.297 seconds

The Integer Number Divider Using Improved Reciprocal Algorithm (개선된 역수 알고리즘을 사용한 정수 나눗셈기)

  • Song, Hong-Bok;Park, Chang-Soo;Cho, Gyeong-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1218-1226
    • /
    • 2008
  • With the development of semiconductor integrated technology and with the increasing use of multimedia functions in computer, more functions have been implemented as hardware. Nowadays, most microprocessors beyond 32 bits generally implement an integer multiplier as hardware. However, as for a divider, only specific microprocessor implements traditional SRT algorithm as hardware due to complexity of implementation and slow speed. This paper suggested an algorithm that uses a multiplier, 'w bit $\times$ w bit = 2w bit', to process $\frac{N}{D}$ integer division. That is, the reciprocal number D is first calculated, and then multiply dividend N to process integer division. In this paper, when the divisor D is '$D=0.d{\times}2^L$, 0.5 < 0.d < 1.0', approximate value of ' $\frac{1}{D}$', '$1.g{\times}2^{-L}$', which satisfies ' $0.d{\times}1.g=1+e$, $e<2^{-w}$', is defined as over reciprocal number and then an algorithm for over reciprocal number is suggested. This algorithm multiplies over reciprocal number '$01.g{\times}2^{-L}$' by dividend N to process $\frac{N}{D}$ integer division. The algorithm suggested in this paper doesn't require additional revision, because it can calculate correct reciprocal number. In addition, this algorithm uses only multiplier, so additional hardware for division is not required to implement microprocessor. Also, it shows faster speed than the conventional SRT algorithm and performs operation by word unit, accordingly it is more suitable to make compiler than the existing division algorithm. In conclusion, results from this study could be used widely for implementation SOC(System on Chip) and etc. which has been restricted to microprocessor and size of the hardware.

Comparison of Success Rates after Silicone Tube Intubation with or without Lacrimal Endoscopy for Epiphora (눈물흘림 환자에서 눈물길미세내시경의 사용 여부에 따른 실리콘관삽입술의 성공률 비교)

  • Choi, Min Gyu;Lee, Jeong Kyu
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1001-1008
    • /
    • 2018
  • Purpose: To compare the success rates between silicone tube intubation using a lacrimal endoscope and using a conventional nasal endoscope alone in adult patients suffering from epiphora. Methods: We conducted a retrospective chart review of 80 eyes of 55 patients who underwent silicone tube intubation from January 2014 to June 2017. Patients were preoperatively diagnosed with syringing and dacryocystography. The silicone tube was removed 3 months after surgery and success rates were evaluated at 4 and 12 months. Success rates were analyzed by dividing the patients into two groups, according to lacrimal endoscope use. Results: A lacrimal endoscope was used in 40 eyes. In the group using a lacrimal endoscope, preoperative diagnoses were partial obstruction in 26 eyes and complete obstruction in 14 eyes. In the group without lacrimal endoscope use, preoperative diagnoses were partial obstruction in 35 eyes and complete obstruction in 5 eyes (p = 0.018). The success rates at 4 and 12 months after surgery in the two groups (with and without lacrimal endoscope use) were 87.5% and 80.0% and 72.0% and 62.1% (p = 0.546 and p = 0.565), respectively. The success rates of patients with partial obstruction in the two groups were 92.3% and 82.9% at 4 months and 71.4% and 69.2% at 12 months (p = 0.448 and p = 1.000), respectively. The success rates of patients with complete obstruction in the two groups were 78.6% and 60.0% at 4 months and 72.7% and 33.3% at 12 months (p = 0.570 and p = 0.505), respectively. Site differences, the degree of obstruction, and lacrimal endoscope use had a significant impact on the success rate at 4 and 12 months (p = 0.001 and p = 0.022, respectively). Conclusions: Although silicone tube intubation using a lacrimal endoscope cannot guarantee a significant success rate, it is possible to observe the anatomical structure of the nasolacrimal pathway in real time, such that the appropriate diagnosis and treatment can be performed simultaneously. Because patients diagnosed as having a complete obstruction had a good success rate, we can extend indication of silicone tube intubation as a less invasive approach.

Comparative Effect of Spectacles and Orthokeratology Lenses on Axial Elongation in Children with Mild-to-Moderate Myopia (중등도 이하 소아 근시에서 안경과 각막굴절교정렌즈 착용이 안축장 성장에 미치는 영향 비교)

  • Kim, Tae Hee;Kim, Myung Hun;Kwag, Joo Young;Choi, Jin Seok;Pak, Kyu Hong;Lee, Kyeongwook;Park, Taeseong;Chung, Sung Kun;Hyun, Joo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1009-1016
    • /
    • 2018
  • Purpose: To assess the effect on axial elongation and associated factors between spectacles and of orthokeratology lens (OK) wearing in children with mild to moderate myopia. Methods: A total of one hundred subjects, ranging in age from 6 to 13 years, and with mild to moderate myopia no more than -4.50 diopters in spherical equivalent, visited our clinic from 2013 to 2015. The OK group (75 eyes) and the spectacles group (64 eyes) were compared and analyzed on the axial elongation and associated factors. Results: In the OK group, axial length was elongated in 1 year period with a mean increase of $0.24{\pm}0.29mm$. In spectacles group, axial length was elongated in 1 year period with a mean increase of $0.42{\pm}0.20mm$. The statistically significant suppression of axial elongation was observed in OK group compared to the spectacles group (Mann-Whitney U test, p < 0.05). For OK group, the age of starting OK (Pearson's correlation, r = -0.481, p < 0.05) was the only influencing factor on axial elongation, which had negative correlation with axial elongation. In spectacles group, the age of starting spectacles had negative correlation with axial elongation (Pearson's correlation, r = -0.462, p < 0.05) and baseline spherical equivalent, spherical diopter, cylindrical diopter from manifest refraction had positive correlation with axial elongation. Comparison of axial elongation in orthokeratology lens group and spectacles group by age groups (6 to 9 years [28 eyes], 9 to 13 years [47 eyes]), 9 to 13 years of orthokeratology lens group had the stronger suppression of axial elongation (Mann-Whitney U test, p < 0.05). Conclusions: The OK effectively suppresses axial elongation compared to the spectacles. Although the patients are in age from 9 to 13 years, the axial elongation was effectively suppressed.

Two Cases of Corneal Edema Due to Vaporized Amine (기화된 아민에 의한 각막부종 2예)

  • Hwang, Yousook;Cho, Yang Kyung
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1077-1081
    • /
    • 2018
  • Purpose: We report two cases of corneal edema in patients who presented with bilateral blurry vision due to vaporized amines while working in a polyurethane processing plant. Case summary: A 28-year-old male presented with bilateral blurred vision. His work involved solidifying polyurethane liquid and he often found himself exposed to polyurethane heat and gas. Purpose: We report two cases of corneal edema in patients who presented with bilateral blurry vision due to vaporized amines while working in a polyurethane processing plant. Case summary: A 28-year-old male presented with bilateral blurred vision. His work involved solidifying polyurethane liquid and he often found himself exposed to polyurethane heat and gas. On examination, the patient's uncorrected visual acuity (UCVA) was 20/40 (right) and 30/50 (left). A slit lamp examination revealed subepithelial microbullae in both eyes. The central corneal thickness (CCT) was also increased in both eyes, measuring $698{\mu}m$ (right) and $672{\mu}m$ (left). After prescribing 0.5% moxifloxacin and, 1% fluorometholone eye drops for 3 days in both eyes, the UCVA recovered to 20/40 (right) and 20/20 (left). The CCT decreased to $644{\mu}m$ (right) and $651{\mu}m$ (left), and the microbullae improved significantly in the left eye. The second patient was a 34-year-old female who presented with bilateral decreased visual acuity while at work. She worked in a factory that produced car seat filling. Her UCVA was 20/25 (right) and 20/20 (left). The CCT by specular microscopy was $537{\mu}m$ (right) and $541{\mu}m$ (left). On slit lamp examination, both eyes demonstrated bilateral central subepithelial edema. The patient did not attend any follow-up outpatient appointments after the initial presentation. Conclusions: Exposure to vaporized amines such as polyurethane may causereversible corneal toxicityeven without direct contact. Further consideration should be given to ocular safety and protection from amine compounds in the industrial field.On examination, the patient's uncorrected visual acuity (UCVA) was 20/40 (right) and 30/50 (left). A slit lamp examination revealed subepithelial microbullae in both eyes. The central corneal thickness (CCT) was also increased in both eyes, measuring $698{\mu}m$ (right) and $672{\mu}m$ (left). After prescribing 0.5% moxifloxacin and, 1% fluorometholone eye drops for 3 days in both eyes, the UCVA recovered to 20/40 (right) and 20/20 (left). The CCT decreased to $644{\mu}m$ (right) and $651{\mu}m$ (left), and the microbullae improved significantly in the left eye. The second patient was a 34-year-old female who presented with bilateral decreased visual acuity while at work. She worked in a factory that produced car seat filling. Her UCVA was 20/25 (right) and 20/20 (left). The CCT by specular microscopy was $537{\mu}m$ (right) and $541{\mu}m$ (left). On slit lamp examination, both eyes demonstrated bilateral central subepithelial edema. The patient did not attend any follow-up outpatient appointments after the initial presentation. Conclusions: Exposure to vaporized amines such as polyurethane may causereversible corneal toxicityeven without direct contact. Further consideration should be given to ocular safety and protection from amine compounds in the industrial field.

Clinical Effects of an Improved Pump Reaction Rate and Automatic Occlusion Sensing System in Phacoemulsification (수정체유화장치의 초음파 출력속도 및 자동막힘감지 기능 향상의 술 후 임상결과 비교)

  • Kim, You Na;Lee, Jin Ah;Kim, Jae Yong;Kim, Myoung Joon;Tchah, Hung Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1017-1023
    • /
    • 2018
  • Purpose: A recently introduced phacoemulsification system, the WhiteStar $Signature^{(R)}$ PRO, has demonstrated improved nucleus followability and cutting efficiency via an improved pump regulator with a higher reaction response and an automatic occlusion sensing system. In this study, we compared various phacoemulsification parameters between the new system and an older version of the device. Methods: A total of 80 eyes of 68 patients with cataracts who had undergone phacoemulsification by a single surgeon were included in this study. Forty eyes of patients underwent phacoemulsification using the older $Signature^{(R)}$ system (WhiteStar); these patients were classified as the control group. Another 40 eyes of patients underwent phacoemulsification with the newer enhanced system, the WhiteStar $Signature^{(R)}$ PRO; these patients were assigned to the experimental group. During the operation, operative parameters, including the effective phaco time (parameter of effective phaco time with a specific coefficient for the transversal movement expressed in seconds, EFX), ultrasound time (seconds [s]), effective phacoemulsification time (EPT, s), average phacoemulsification power (AVG, %), and balanced salt solution usage, were measured to determine the performance enhancement offered by the updated system. Central corneal thickness was measured before and after surgery to compare corneal edema. The relationships between the two groups were analyzed using an independent t-test. Results: The Signature $PRO^{(R)}$ system showed a lower EFX (p < 0.001), a shorter EPT (p < 0.001), and a smaller AVG (p < 0.001). Postoperative corneal thickness did not differ significantly between the two groups. Conclusions: Comparing the efficacy of the improved reaction speed of the device and automatic occlusion sensing system in performing phacoemulsification, the updated Signature $PRO^{(R)}$ system demonstrated superior followability and cutting efficiency regardless of nuclear cataract hardness.

Effects of conditions for anodization and cyclic precalcification treatments on surface characteristics and bioactivity (양극산화와 석회화 순환처리 조건이 타이타늄 박판의 표면특성 및 생체활성에 미치는 영향)

  • Jang, Yong-Seok;Lee, Kang-Gyu;Jeon, Woo-Yong;Han, A-Lum;Lim, Chung-Ha;Lee, Min-Ho;Bae, Tae-Sung
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.243-256
    • /
    • 2018
  • The purpose of this study was to investigate the effects of the anodization and cyclic calcification treatment on the surface characteristic and bioactivity of the titanium thin sheet in order to obtain basic data for the production of bioactive titanium membrane. A $30{\times}20{\times}0.08mm$ titanium sheets were prepared, and then they were pickled for 10 seconds in the solution which was mixed with $HNO_3:HF:H_2O$ in a ratio of 12: 7: 81. The $TiO_2$ nanotube layer was formed to increase the specific surface area of the titanium, and then the cyclic calcification treatment was performed to induce precipitation of hydroxiapatite by improvement of the bioactivity. The corrosion resistance test, wettability test and immersion test in simulated body solution were conducted to investigate the effect of these surface treatments. The nanotubes formed by the anodization treatment have a dense structure in which small diameter tubes are formed between relatively large diameter tubes, and their inside was hollow and the outer walls were coupled to each other. The hydroxyapatite precipitates were well combined on the nanotubes by the penetration into the nanotube layer by successive cyclic calcification treatment, and the precipitation of hydroxyapatite tended to increase proportionally after immersion in simulated body solution as the number of cycles increased. In conclusion, it was confirmed that induction of precipitation of hydroxyapatite by cyclic calcification treatment after forming the nanotube $TiO_2$ nanotube layer on the surface of the titanium membrane can contribute to improvement of bioactivity.

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Clinical Significance of Antibodies Against Platelet HLA Class I in Children with Idiopathic Thrombocytopenic Purpura (소아 특발성 혈소판 감소증에서 항-HLA Class I항체의 임상적 의미)

  • Lee, Hong Jun;Yeom, Jung-Sook;Park, Ji Sook;Park, Eun Sil;Seo, Ji-Hyun;Lim, Jae Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang
    • The Korean Journal of Blood Transfusion
    • /
    • v.24 no.3
    • /
    • pp.233-240
    • /
    • 2013
  • Background: A previous history of transfusion has been known to be associated with production of anti-HLA class I antibodies. However, platelet glycoproteins are the main target of idiopathic thrombocytopenic purpura (ITP). The mechanism of antibody production is known to differ significantly between glycoproteins and anti-HLA class I. The aim of this study was to evaluate the clinical significance of anti-HLA class I antibodies in childhood ITP. Methods: Enrollment for the normal control group targeted 48 people who visited Gyeongsang National University Hospital from 1990 to 2010, and 48 young children with ITP. Anti-glycoproteins and anti-HLA class I antibodies were tested using the Modified Antigen Capture Enzyme-linked immunosorbent assay (MACE) kit. Results: The positive rate of anti-HLA antibodies was significantly different [36/39 (92.3%) vs 29/46 (63%)] [ITP group vs normal control group] (P=0.002). The mean positive S/C ratio of anti-HLA antibodies was also significantly different (3.55 vs 1.51) [ITP group vs normal control group] (P=0.0000). The positive rate of anti-HLA did not differ significantly between the transfused group and the non-transfused group [12/12 (100%) vs 24/27 (88%)] [transfused ITP vs non-transfused ITP]. The mean positive S/C ratio of anti-HLA antibodies did not differ significantly between the transfused ITP group and the non-transfused ITP group (4.30 vs 3.25) [transfused ITP vs non-transfused ITP]. Consecutive testing showed that positive rate and positive S/C ratio of anti-HLA antibodies did not change significantly between sampling times in both groups [transfused ITP vs non-transfused ITP] (P=1.00 and P=0.15). Conclusion: Anti-HLA class I antibodies may be involved in childhood ITP. Transfusion did not affect the course of childhood ITP.

Two Cases of Long-Term Changes in the Retinal Nerve Fiber Layer Thickness after Intravitreal Bevacizumab for Diabetic Papillopathy (당뇨병유두병증에서 유리체강내 베바시주맙 주입술 후 망막시경섬유층 두께의 장기간 변화 2예)

  • Kim, Jong Jin;Im, Jong Chan;Shin, Jae Pil;Kim, In Taek;Park, Dong Ho
    • Journal of The Korean Ophthalmological Society
    • /
    • v.54 no.9
    • /
    • pp.1445-1451
    • /
    • 2013
  • Purpose: To report long-term changes in the average retinal nerve fiber layer (RNFL) thickness in 2 patients who had intravitreal bevacizumab (IVB) injection for diabetic papillopathy. Case summary: A 36-year-old patient with diabetes complained of decreased visual acuity (20/200) in the right eye. The fundus examination showed optic disc swelling in both eyes. The average RNFL thickness based on optical coherence tomography (OCT) increased to $278{\mu}m$ and Goldmann perimetry showed nasal visual field defect in the right eye. The IVB was injected into the right eye. Three weeks after the IVB injection, RNFL thickness decreased to $135{\mu}m$ and visual acuity improved to 20/25 in the right eye. However, RNFL thickness increased from 126 to $207{\mu}m$ and visual acuity decreased to 20/32 in the left eye. Thus, IVB was injected into the left eye. In week 3, RNFL thickness decreased to $147{\mu}m$ and visual acuity improved to 20/20 in the left eye. At 12 months after IVB injection, RNFL thickness was $87{\mu}m$ in the right eye and $109{\mu}m$ in the left eye. A 57-year-old patient with diabetes complained of decreased visual acuity (20/200) and showed optic disc swelling in the right eye. The average RNFL thickness increased to $252{\mu}m$ and Goldmann perimetry showed an enlarged blind spot in the right eye. IVB was injected into the right eye. After 3 weeks, RNFL thickness decreased to $136{\mu}m$ and visual acuity improved to 20/70 in the right eye. Six months after IVB injection, RNFL thickness was $83{\mu}m$ in the right eye. Conclusions: Visual acuity progressively improved within 3 weeks and RNFL thickness measured by spectral domain OCT showed progressive thickness reduction in 2 cases of diabetic papillopathy patients who had IVB injections.

An Epidemiologic Survey of Strabismus and Nystagmus in South Korea: KNHANES V (인구역학적 요인에 따른 한국인의 사시 및 눈떨림 유병률 조사: 제5기 국민건강영양조사 자료)

  • Lee, Ji Eun;Kim, Chang Zoo;Nam, Ki Yup;Lee, Seung Uk;Lee, Sang Joon
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.11
    • /
    • pp.1260-1268
    • /
    • 2017
  • Purpose: Strabismus affects any age and represents various functional or non-functional eye problems. This population-based study was conducted to determine the prevalence of strabismus and nystagmus in South Korea according to various sociodemographic factors. Methods: We acquired data from the Korea National Health and Nutrition Examination Survey, a nation-wide cross-sectional survey and examinations of the non-institutionalized civilian population in South Korea (n = 30,538), conducted from July 2008 to December 2011. The prevalence of strabismus and nystagmus were verified, and associated sociodemographic factors was evaluated. Results: The overall prevalence of strabismic disorder in participants over 3 years of age was $1.4{\pm}0.1%$ (95% confidence interval [CI] 1.3-1.6%; $1.5{\pm}0.1%$ in males, $1.3{\pm}0.1%$ in females). The prevalence of exodeviation (15 or more prism diopters), esodeviation (10 or more prism diopters), vertical deviation, and other complicated strabismus and nystagmus was 1.0%, 0.2%, 0.2%, 0.1% and 0.1% respectively. The prevalence was highest in the 6 to 15-year age group ($1.9{\pm}0.3%$), and lowest in the 40 to 49 years age group ($0.8{\pm}0.1%$) (p = 0.005). There were no statistically significant differences for gender, region, residential area, household income, educational level and occupation. Conclusions: This nation-wide epidemiologic study demonstrated that the prevalence of strabismus and nystagmus according to various sociodemographic factors in South Korea was not statistically significant except for age group. Further investigations are required based on more surveys to better recognize the etiologic or risk factors that may be related to strabismus and nystagmus.