• 제목/요약/키워드: 수두손실계수

Search Result 38, Processing Time 0.024 seconds

이상류에서의 펌프특성 연구

  • 김주철;김상녕
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.342-349
    • /
    • 1997
  • 국내 원자력발전소의 참조격인 영광 3ㆍ4호기의 RCP를 1/10으로 축소한 모델펌프를 설계ㆍ제작하여 상온, 대기압에서 단상류 펌프특성과 포화상태 근방에서 공동현상 시발 과냉각온도($\Delta$T$_{sub}$ ) 실험을 수행하였다. 단상류 특성은 RCP와 유사하였고, 공동현상 시발 $\Delta$T$_{sub}$ 는 0~5$^{\circ}C$였으며, 압력에 따라 민감하였다. 공동현상의 무차원 변수는 Ca=(equation omitted)로 정의된다. 단상류 펌프특성과 이상류 펌프특성간의 상관관계인 수두손실비 H$^{*}$ (equation omitted)를 기포율($\alpha$)와 유량계수(ø)의 함수로 나타낼 수 있을 것이다.

  • PDF

An Experimental Study for Estimation of Head Loss Coefficients at Surcharged Combining Junction Manholes (과부하 합류맨홀에서의 손실계수 산정을 위한 실험적 연구)

  • Kim, Jung-Soo;Choi, Hyun-Soo;Yoon, Sei-Eui
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.5
    • /
    • pp.445-453
    • /
    • 2010
  • Energy loss at manholes, often exceeding friction loss of pipes under surcharged flow, is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze head losses at manholes, especially in case of surcharged flow. Hydraulic experimental apparatus which can change the manhole shape (square, circular) were installed for this study. In the experiments, two inflows ($Q_1,\;Q_2$) were varied from 0 to $4{\ell}$/sec and 15 combinations were tested in total. The flow ratios $Q_2/Q_3$ were varied from 0 to 1 for a total flow $Q_3$ ($Q_3=Q_1+Q_3$) of 2, 3, and $4{\ell}$/sec, respectively. The variation of head losses were strongly influenced by the lateral inflow because the head loss coefficient increases as the flow ratio $Q_2/Q_3$ increases. There was no significant difference of head loss between square manhole and circular one, and also no large variation of head loss as discharges change. The relation equations between K and $Q_2/Q_3$ were suggested in this paper.

Fractal Model of Transient Flow in a Dual-porosity Aquifer with Constant-head Upper Boundary (일정수두 상부경계를 가지는 이중공극 대수층내 부정류에 관한 프락탈모델)

  • 함세영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 1997
  • So far, several fractal models of fluid flow in a fractured aquifer have been developed. In this study, a new fractal model is derived that considers transient flow in the dual-porosity aquifer with the fracture skin between the fissure and the block, and the storage capacity and the wellbore skin on the pumping well. Constant-head upper boundary is specified in the block. This model is a generalized one which comprises both modified Hantush equation (1960) and Boulton-Streltsova equation (1978). Type curves are plotted for different flow dimensions (0.5, 1, 1.5, 2, 2.5 and 3) with various values of the leakage factor and the fracture skin. They show dimensionless drawdown in the pumping well and observation wells located either in the fissure system or in the matrix block.

  • PDF

Dynamic Characteristics of Tuned Liquid Column Dampers Using Shaking Table Test (진동대실험에 의한 동조액체기둥감쇠기의 동적특성)

  • Min, Kyung-Won;Park, Eun-Churn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.620-627
    • /
    • 2009
  • Shaking table test was carried out to obtain dynamic characteristics of TLCDs with uniform and non-uniform sections for both horizontal and vertical tubes. The input to the table is harmonic acceleration with constant magnitude. The output is horizontal dynamic force which is measured by load cell installed below the TLCD. Transfer functions are experimentally obtained using the ratio of input and output. Natural frequency, the most important design factor, is compared to that by theoretical equation for TLCDs with five different water levels. System identification process is performed for experimentally obtained transfer functions to find the dynamic characteristics of head loss coefficient and effective mass of TLCDs. It is found that their magnitudes are larger for a TLCD with non-uniform section than with uniform section and natural frequencies are close to theoretical ones.

A study on the effects of Friction loss of CPVC pipe according to Roughness coefficient in a sprinkler system (스프링클러 시스템에서 조도계수에 따른 CPVC 배관 마찰손실 영향의 연구)

  • Kang, Ung Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.355-362
    • /
    • 2016
  • The pipe material is selected according to the physical and chemical properties of the fluid flowing within it. Because the fluid used in fire extinguish systems is water, the various foreign substances dissolved in it cause scale to form on the pipe wall and accelerate the corrosion and aging of the pipe itself. This results in an increase in the friction loss and eventually degrades the efficiency of the pump. The use of CPVC (Chlorinated Poly-Vinyl Chloride) pipes was confirmed to reduce the friction loss compared to conventional steel pipes in the design and construction stages. The friction loss was found to be 76.64MPa with a C-value of 120 for the steel pipe and 50.72 MPa with a C-value of 150 for the CPVC pipe in an actual apartment construction environment. It was confirmed that the friction loss was improved by about 34% when using the CPVC pipe. When the steel and CPVC pipes were employed in the construction, the construction costs were 1,585,158 and 931,842 won, respectively. Therefore, it was shown that the construction cost was reduced by about 41%. We investigated the safety of the fire extinguishing system and the improvement in the economic performance due to the reduction in the total installed capacity by studying practical applications in the field.

A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration (홍수터여과에서 집수관의 최적설계 연구)

  • Pi, Seong-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.430-437
    • /
    • 2012
  • In order to obtain information on the design parameters of the horizontal laterals in floodplain filtration, laboratory-scale sand-box experiments were performed where the head distributions on the laterals and the groundwater profiles were measured according to the change in parameters including lateral diameter, hydraulic conductivity of the sand, water level at the well and raw-water supply rate. Measured data were analyzed using a numerical code in order to identify the discharge intensity distribution along the laterals. It was observed from the result that the lowering of the water level at the well had minimal adverse effect on the performance of the floodplain filtration. Results also elucidated that the low conveyance of the laterals to transmit the filtrate was compensated and supplemented by a natural augmentation in horizontal conveyance through the aquifer when the raw-water supply rate exceeded the adequate recovery rate. With this mechanism, the water quality is expected to improve further since the travel distance through the aquifer is amplified. Based on these findings it can be suggested that the diameter of the lateral used in the floodplain filtration may be smaller than those in riverbank/bed filtration. It was also found that the ratio between the head loss occurring in a lateral and the total head loss in the floodplain filtration was proportional to the exit velocities of the laterals, which may be used to design and/or evaluate the lateral in floodplain filtration.

Numerical Analysis of Subsurface Flow in a Hillslope (자연 구릉지에서 지표하 흐름의 수치해석)

  • 최은호;남선우
    • Water for future
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 1991
  • The governing equation of flow in porous media is developed on the bases of the continuity equation of fluid for transient flow through a saturated-unsaturated zone, and substitution of Darcy's law. The numerical solutions are obtained by finite element method based on the Galerkin principles weighted residuals. The analysis are carried out by using the unsteady storm data observed and rainfall intensities which are obtained by using the rainfall excess model in considering of the initial losses. The functional relationships between the hydraulic conductivity, capillary pressure head and volumetric water content are applied to the flow of water through unsaturated soil varied with changes of water content.

  • PDF

유공Caisson식 방파제에 작용하는 파력에 관한 연구

  • 안수한;편종근
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1980.08a
    • /
    • pp.44-46
    • /
    • 1980
  • 파의 에너지 감쇠기구의 관점에서 볼 때 분류손실방식인 유공벽식 방파제 중에서 원형공이 벽 전체에 균일하게 분포되어 있고 구멍 직경에 비해 벽 두께가 얇은 삼중 유공벽형 Caisson의 각 벽에 작용하는 파력에 고나해 이론적 접근과 실험을 통한 실증을 시도해 보았다. 이론적인 방법으로는 토굴구효남의 이론을 응용하였으며 주어진 파랑조건에 대해 각 유공벽 전 후면에 연속방정식과 Bernoulli 방정식을 이용하여, 각 영역별 연속 Potential의 진폭과 위상각에 대한 비선형 12원 연립방정식을 만들었고 Computer를 이용하여 반복법으로 각 속도 Potential을 확정하였다. 이렇게 구한 속도 Potential을 압력방정식에 대입하여 각 벽별 파력을 계산하였으며 동일한 파랑조건하의 실험에서 각 벽별 파력을 측정하여 양자를 서로 비교검토하였다. Bernoulli의 방정식중 에너지 손실항은 의사비선형으로 처리하였다. 유공율조합 0.25-0.3-0.2이고, 판두께가 1cm인 모형의 실험결과, 각 벽별 최대파력치의 특성으로서는 첫때, S-2, S-3등 간벽에 작용하는 파력이 전벽 및 후벽에 비해 두드러지게 작다는 사실과, 둘째 작용파력의 크기 순이 파형경사가 작을 때는 대략 S-4, S-1, S-2, S-3순이고 파형경사가 클 때에는 대략 S-1, S-4, S-2, S-3순이라는 점 등을 들 수 있겠다. 굴구효남이 가정한 f의 치 1.5를 사용하여 계산한 각 벽별 최대파력을 실험치와 비교해 본 결과, 파가 각 유공벽을 통과할 때의 손실수두를 실험에서의 양만큼 fr=1.5를 가정한 수학적 model이 설명해 주지 못한다고 볼 수 있으므로 두가지 방법에 의하여 본 실험에서 사용한 유공판의 손실계수를 근사적으로 추정하여 보았다. 추정한 f를 사용하여 다시금 각 벽별 최대파력을 계산하고 실험치와 비교해 보면 훨씬 서로 근접함을 알 수 있었다. 결국 본 논문의 이론을 사용하면 유공Caisson문제의 전체적인 윤곽 및 각 변수들의 파력에 대한 영향을 파악할 수 있겠다.

  • PDF

Geotechnical Characteristics of Prefabricated Vertical Drain System for Contaminated Soil Remediation (오염토양 복원을 위한 연직배수시스템의 지반공학적 특성)

  • Shin, Eunchul;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.5-14
    • /
    • 2007
  • The quantity of noxious wastes generated by the growth in industrialization and population in all over the world and its potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. Incorporated technique with PVDs have been used for dewatering from fine-grained soils for the purpose of ground improvement by means of soil flushing and soil vapor extraction systems. This paper is to evaluate several key parameters that affected to the performance of the PVDs specifically with regard to: well resistance of PVD, zone of influence, and smear effects. In the feasibility of contaminant remediation was evaluated in pilot-scale laboratory experiments. Well resistance is affected on the vertical discharge capacity of the PVDs under the various vacuum pressures. The discharge capacity increases consistently in areal extents with higher applied vacuum up to a limiting vacuum pressure. The head values for each piezometer at different vacuum pressures show that the largest head loss occurs within 14 cm of the PVD. Air flow rates and head losses were measured for the PVD placed in the model test box and the gas permeability of the silty soils was calculated. Increasing the equivalent diameter results in a decrease in the calculated gas permeability. It is concluded that the gas permeability determined over the 1,500 to 2,000 $cm^3/s$ flow rates are the most accurate values which yields gas permeability of about 3.152 Darcy.

  • PDF