• Title/Summary/Keyword: 송전철탑

Search Result 138, Processing Time 0.027 seconds

송전선의 뇌해대책 현상과 전망

  • 김경호
    • Electric Engineers Magazine
    • /
    • v.204 no.8
    • /
    • pp.48-53
    • /
    • 1999
  • 송전선에서의 낙뢰재해에 관해서는 지금까지 시행하고 있는 각공지선 또는 아킹혼의 설치, 철탑 접지저항 저감을 위한 매설지선의 설치 그리고 일본 전력회사에서 시행하고 있는 알루미늄을 함유한 애자의 채용 등 여러 가지 대책을 시행한 결과 낙뢰로 인한 설비 피해사고는 현격하게 감소되었다.

  • PDF

The performance evaluation of the polymer arm insulator for a compact transmission line tower (친환경적인 컴팩트 송전탑용 폴리머 절연암의 성능평가에 관한 연구)

  • Song, Hong-Jun;Park, Gi-Ho;Kim, Gwan-Hyung;Byun, Gi-Sik;Hwang, Yeong-Yeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.341-347
    • /
    • 2009
  • As a right-of-way security for the high power transmission line tower construction is becoming more and more difficult, the friendly environmental compact tower design is required. For a proper insulation for the compact tower, the polymer material are being tried. Some countries has already adapted, in the various polymer application and management data, polymer arm insulator to the transmission tower, and shown a stable operation. However, in our country, the polymer arm insulator has left much to be desired in the installation on the transmission line tower. But polymer material has been developed by high strength and technology and is expected to be used in various electric equipments. The polymer arm insulator is a one of good electric insulation materials to expand the power supply capacity in the rapid power demand increasement In this research, the new polymer am insulator is designed and its electric specifications are analyzed. Its mechanical specifications is verified through the field test on the compact tower which is modified by the polymer arm insulator.

Study on the Assessment technique and Design Standard for Wind Load on Transmission Tower (송전용 지지물 풍하중 산정기법 및 기준제정에 관한 연구)

  • Shin, Koo-Yong;Lim, Jea-Seob;Lee, Dong-Il;Whang, Kab-Cheol;Bang, Hang-Kweon;Shin, Tae-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.452-453
    • /
    • 2008
  • 본 논문에서는 송전철탑에 작용하는 설계하중으로서 [송전철탑 설계풍속에 관한 연구]에 근거하여 1987년 6월 제정된 지역별설계 풍하중기준의 개정을 위한 연구결과를 수록하였다. 당시 제정된 송전설계기준은 이전에 전국적으로 통일시켜 적용되던 풍속압($76kg/m^2$)을 지역별 풍속을 구분하여 그 차이에 따라 I, II, III, 지역 및 울릉도로 구분하여 차등 적용하였으며, 본 연구에서는 국내 기상청이 생긴 이래 2005년까지 누적된 기상 DB의 분석을 통하여 최근의 기상 현상을 반영한 보다 현실적인 설계기준 개정과정을 수록하였다. 본 논문에서는 1980년대 후반부터 약 20년간의 기상청의 풍향, 풍속자료를 추가로 확보하여 이를 분석하고 재현기간을 반영한 지역별 설계하중을 재산정하여 최근의 기상자료를 포함하여 보다 정확한 분석을 도모하고, 사회 환경의 급변함에 따라 우려되는 기상이변 등을 고려한 안전성과 경제성이 향상된 설계기준의 산정과정을 고찰하고자 한다.

  • PDF

A design of 150 meters high steel tower (150m 철탑의 설계 ( 2 ))

  • 이재숙
    • 전기의세계
    • /
    • v.17 no.4
    • /
    • pp.28-31
    • /
    • 1968
  • 본 철탑설계이서 느끼는 점은, 장차 우리나라에서 건설할 345KV 송전용철탑도 국내에서 설계가능함은 물론, 조합부재방식을 활용하면 소요강재도 대부분국산품을 충당할 수 있을 것이다. 그리고, 국내기술의 향상을 위해서는 기술자에게 연구하고, 설계할 수 있는 시간적여유등 여건향상이 절대로 필요하다는 것이다. 국내에서 사용하는 기기는 우리나라 기술자가 국산자재를 이용하는 방침하에서 설계하고 설계가 끝난다음 이것을 국내에서 가공 또는 제작해야 많은 와화도 절약할 수 있고, 생산비도 절하할 수 있고 국내산업의 유기적발전을 기대할 수 있는 것이다.

  • PDF

Aging Deterioration for Electric Power Transmission Tower on Offshore Through Periodic Inspections (해상송전철탑 구조물의 주기점검을 통한 경년열화 변화특성)

  • Lee, Ho Beom;Jang, Il Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.25-33
    • /
    • 2012
  • In electric power transmission tower structures on offshore, implementation of life management using the event data of regular safety inspections for structural and material damages is strongly recommended. In this study, six tower structures in Sihwa Lake around Yeoungheung island were target bodies for the safety inspections. safety inspections for deterioration about each of six towers were performed about three items for steel member, five items for concrete foundation, and four items for steel-pipe pile in seawater and seawater itself. Safety inspections for steel members included the visual observations of surface appearances, the measurements of member thicknesses, and the checks of painting states. Also safety inspections for concrete foundations comprised the estimation of crack features, the evaluation of non-destructive compression strengths, and the measurements of neutralization depths and chlorides contents. For steel-pipe piles in seawater the inspections comprised the surveys of corrosion states in accordance with potential levels tests and anode tests, the analyses of photos taken on surfaces of the piles as well as the evaluation of seawater quality. A set of deterioration inspections was performed at the same positions around october of each year for three consecutive years. As a result in this study, Newly developed deterioration indexes have been applied profitably to maintain structural safety for electric power transmission towers by utilizing these event data systematically.

Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines (송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기)

  • Moon, Byoung-Wook;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.

An analysis of Phase Array using EMTDC (An analysis of ${\pi}$-Branch Transmission Line Unbalance) (EMTDC를 이용한 송전선로 상배치 분석 (${\Pi}$분기 선로 불편형 분석))

  • Han, Jeong-Yeul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.345-347
    • /
    • 2006
  • 신설 선로와 기존 선로와의 계통 연계시 상 배치에 따라 연계 후 발생하는 급격한 영상전류의 증가로 인하여 지락계전기의 동작 같은 계통에 악 영향을 미치는 현상이 일어난다. 이 논문은 송전선로의 연가철탑을 이용한 역상배치 시행여부에 따른 계통 해석과 상시 불평형률을 문경 변전소 신설에 따라 10월 가압 목표로 시공 중인 송전선로의 $1{\pi}$분기와 관련하여 ${\pi}$분기시의 이상적인 송전선로 상 배열을 분석한다.

  • PDF