In electric power transmission tower structures on offshore, implementation of life management using the event data of regular safety inspections for structural and material damages is strongly recommended. In this study, six tower structures in Sihwa Lake around Yeoungheung island were target bodies for the safety inspections. safety inspections for deterioration about each of six towers were performed about three items for steel member, five items for concrete foundation, and four items for steel-pipe pile in seawater and seawater itself. Safety inspections for steel members included the visual observations of surface appearances, the measurements of member thicknesses, and the checks of painting states. Also safety inspections for concrete foundations comprised the estimation of crack features, the evaluation of non-destructive compression strengths, and the measurements of neutralization depths and chlorides contents. For steel-pipe piles in seawater the inspections comprised the surveys of corrosion states in accordance with potential levels tests and anode tests, the analyses of photos taken on surfaces of the piles as well as the evaluation of seawater quality. A set of deterioration inspections was performed at the same positions around october of each year for three consecutive years. As a result in this study, Newly developed deterioration indexes have been applied profitably to maintain structural safety for electric power transmission towers by utilizing these event data systematically.
Keywords
Electric power transmission towers on offshore; Life management; Structural and material damages; Indexes of deterioration factors;
Citations & Related Records
연도 인용수 순위
  • Reference
1 건설교통부(시설안전기술공단), "안전점검 및 정밀안전진단 세부지침(교량, 항만)".
2 (주)쓰리텍, "345kV 영흥 T/L 축도 철탑 No. 108 송전탑 구조 안전성 평가 및 대책 결과보고서", 2006. 10.
3 한국전력공사 전력연구원, "345kV 영흥T/L 해상철탑구조물 수명관리 방안 연구", 04 전력연-단463, 2004. 8.
4 한국전력공사, "영흥 해상 철탑기초 구조물의 유지관리 지침서".
5 한국전력공사, "가공송전선용 철탑설계기준-1111".
6 한국전력연구원, "345kv 영흥T/L 해상철탑구조물 수명관리 방안연구", 2004.
7 한상묵, 방기성, 김도겸, 정송수, "345k 영흥T/L 해상철탑구조물 콘크리트 매트 기초의 유지관리 방안 연구", 2004년도 학술발표회 논문집, 대한토목학회, 2004, pp.509-512.
8 KOPEC, "345kV 영흥 T/L 건설공사 시화호구간 I, II형, "SB2 형 강관철탑 설계도", 2002. 8.
9 KOPEC, "345kV 영흥 T/L 건설공사 시화호구간 I, II형, "SD2 형 강관철탑 설계도", 2002. 8.
10 KOPEC, "345kV 영흥 T/L 건설공사 해상구간 1차분 2형 "SB2 TYPE 강관철탑 설계도", 2002. 8.