• Title/Summary/Keyword: 송신음압감도

Search Result 5, Processing Time 0.018 seconds

Analysis of the Resonant Characteristics of a Tonpilz Transducer with a Fixed Tail Mass by the Equivalent Circuit Approach (등가회로를 이용한 후면추 고정형 Tonpilz 트랜스듀서의 공진 특성 해석)

  • Kim, Jin-Wook;Kim, Won-Ho;Joh, Chee-Young;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.344-352
    • /
    • 2011
  • In this paper, the resonant characteristic of a Tonpilz transducer with a fixed tail mass has been studied by means of an equivalent circuit approach. An equivalent circuit has been designed to describe the characteristic of a Tonpilz transducer that has an additional resonance because of its fixed tail mass. The transmitting voltage response of the transducer calculated by the designed circuit has been compared with that by the FEA (finite element analysis) to confirm the validity of the circuit. This equivalent circuit approach produces identical results with the FEA, in which the variation of resonant frequencies and TVR has been clearly figured out in relation to the stiffness of the mounting fixture and the mass of the tail mass. The suggested equivalent circuit can be utilized to figure out the characteristics of the Tonpilz transducer more efficiently than FEA that requires much calculation time and revision of the models in accordance with the variation of design variables.

Equivalent Circuit Modeling of Underwater Acoustic Piezoelectric Transducer (수중 음향 압전 트랜스듀서의 등가 회로 모델링)

  • Joh, Chee-Young;Seo, Hee-Seon;Lee, Jung-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.77-82
    • /
    • 1996
  • In this paper an identification method is presented to obtain the equivalent electric model of a sandwitch type piezoelectric transducer. Unknown parameters related to the equivalent circuit are identified by solving a nonlinear optimization problem which can minimize an error between the experimental and analytical admittances in air. The proposed method is applied to an example transducer. The validity of equivalent circuit model is demonstrated by the comparison between the experimental measurements and analytical calculations of transmitting voltage response(TVR) and receiving voltage response(RVS).

  • PDF

Study on the Wideband Tonpilz Transducer with a Cavity-Type Head Mass (중공형 전면추를 가진 Tonpilz 트랜스듀서 연구)

  • Kim, Hyunki;Lim, Youngsub;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.94-101
    • /
    • 2014
  • In this work, we present an underwater acoustic transducer with a cavity-type head mass to achieve a wide frequency bandwidth. We analyzed the effects of design variables on the transducer characteristics, and optimized the structure of the Tonpilz transducer based on the analysis results. Further, validity of the design was verified by manufacturing a prototype of the transducer and measuring its properties. The designed transducer had a far wider -6 dB fractional bandwidth which is 131 % than that of a single mode transducer, and the measured results were confirmed to be in good agreement with the analysis results.

Design and Fabrication of Multi-mode Wideband Tonpilz Transducers (다중모드 광대역 Tonpilz 트랜스듀서의 설계 및 제작)

  • Kim, Jinwook;Kim, Hoeyong;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.191-198
    • /
    • 2013
  • In this paper, we designed a wideband Tonpilz transducer, and verified the validity of the design through experiments. The wide frequency bandwidth was achieved by coupling the fundamental longitudinal mode of the transducer with a flapping mode of the head mass. Structure of the Tonpilz transducer was optimized by means of the finite element method and genetic algorithm to achieve the widest fractional bandwidth under design constraints. The optimized structure showed a far wider -6 dB fractional bandwidth of transmitting responses than that of single mode transducers. For verification of the design result, we manufactured a transducer prototype of the designed structure and characterized its performance, which showed good agreement with the design results.

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (1) - Design and production of system - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (1) -시스템의 설계 및 제작 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.218-229
    • /
    • 2003
  • A new biotelemetry method that the installation and the treatment of equipment is convenient and the instantaneously detailed location of the fish attached the pinger is able to track comparatively easily was developed. The receiving system in this biotelemetry method was advanced for track the detailed behavior of the fish by the miniature tracking pinger, because it was a burden to fish to add the pinger with the water temperature and the pressure sensor. By combining of the super short base line (SSBL) method to detect the direction of pinger and the pinger synchronizing method to measure the range from receiving transducer to pinger, the three dimensional locations of fish to the receiving transducer is gotten instantaneously. The receiving system is devised to realize the high precision or wide detection range by application of the basic design method for receiving system of biotelemetry developed by the present authors and the hydrophone array configuration. The measurement distance error in the pinger synchronizing method is minimized through the correction of which the deviation of transmission pluse period of pinger is caused by changing water temperature. A prototype system which is able to track the instantaneously detailed location of the fish by the SSBL and pinger synchronizing biotelemetry (SPB) method was produced.