해외 송변전 사업 추진사례(미얀마 전력망 진단 및 분석) (Development Study on the Power System Analysis in Myanmar)

  • 문봉수;방민재;최호진;김종화;김세현;최영성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.51-53
    • /
    • 2004
  • KEPCO is now promoting the overseas transmission businesses on the basis of competitive transmission technology. This paper deals with a development study on the power system network analysis in Myanmar which was performed as the first overseas transmission business of KEPCO. The aim of this study is to establish comprehensive and stable power system network plan by analyzing the current and future system in Myanmar.

  • PDF

154kV 주변압기 2차측 전력용 케이블 불평형 전류 저감 대책 (Measures to reduce the unbalance current of secondary power cable of 154kV main transformer)

  • 전상동;오장만;김기일;정규원;유희영;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.338_339
    • /
    • 2009
  • 송전전압을 배전전압으로 변성하여 고객에게 배분하는 154kV 주변압기의 경우 과거 옥외철구형 변전소에서는 주로 동을 이용한 모선을 이용하였다. 최근 부지확보의 어려움 및 빈번한 민원 발생으로 지하 또는 옥내변전소로 바뀌어 가는 추세이고 과거 동모선 방식에서 케이블을 이용한 방식이 선호되고 있다. 모선방식의 경우는 구리나 알루미늄 바의 부식문제, 습기문제, 그리고 좁은 공간에서 사용시 절연 문제 등과 관련하여 지속적인 관리가 요구되고 있으나 케이블을 사용할 경우 이러한 문제들로부터 벗어날 수 있는 이점을 가지고 있다. 그러나 케이블을 사용하여 대전류를 송전할 경우 단일 케이블의 허용전류 용량에 따른 제한으로 복수의 케이블을 병렬 연결하여 사용하여야 한다. 그러나 케이블 동상 병렬사용시 케이블 포설 방식에 따라 동상간의 불평형전류 차가 심하게 발생한다. 본 논문에서는 이러한 송 배전 선로의 불평형전류 현황을 알아보고, 송전선로에 있어서 상배열 변경 및 배전선의 동상 케이블 배열방법을 변경함으로써 불평형전류를 최소화 하여 최적의 계통상태 유지를 위한 방안을 찾고자 한다.

  • PDF

IEC 61850 기반의 IED 통합 엔지니어링 툴 개발 (Development of IEC 61850 based Integration Engineering Tool for Intelligent Electronic Device)

  • 한정열;안용호;장병태;송인준;김용학
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.101-108
    • /
    • 2010
  • IEC 61850 기반의 변전소자동화 시스템을 구축하기 위해서는 실계통 변전소에서 엔지니어링이 가능한 IED 공통의 엔지니어링 툴 개발이 요구된다. 따라서 본 연구에서는 해외 선진사가 지원하는 시스템 및 SCL 구성 툴과 같이 IED 상호간의 통신분석 및 운영관리에 요구되는 IED 통합 엔지니어링 툴을 개발하고자 한다. 본 연구에서 개발된 IED 통합 엔지니어링 툴은 IEC 61850에서 규정하는 XML 기반의 언어로 작성된 ICD, SCL 및CID 파일을 생성, 편집 및 저장할 수 있는 프로그램이다. 특히 IEC 61850 기반으로 국내에서 개발된 IED에 대한 엔지니어링 작업 등 모든 IED에 적용이 가능한 범용적인 툴로써, IED에 대한 신뢰성 검증과 사용자 중심의 편리함과 효율성을 제공할 수 있다는 장점을 갖고 있다.

발전제약완화용 배터리 ESS 효과 분석 및 기술 적용 (Analysis of Battery ESS Technology and its Effects for Generation Constraint)

  • 정솔영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2021
  • 우리나라 서해안 및 동해안지역에는 대규모 발전단지가 집중되어 운영 중이며 이 발전단지들의 발전력을 송전하고 있는 765kV 송전선로 2 회선 고장이 발생하는 경우 송전선로의 용량부족으로 인해서 수 GW 규모의 발전력을 불시에 탈락시키도록 보호체계(SPS, Special Protection System)가 운영 중이다. 이 SPS 가 동작하여 대규모 공급능력이 불시에 상실되면 급격한 주파수 하락이 발생하게 되어 저주파수계전기(Under Frequency Relay, UFR)가 동작할 수 있기 때문에 SPS 탈락 발전기의 출력을 상시에 감소시키는 제약비발전(Constraint off)을 시행하고 있다. 이 제약비발전으로 인해 매년 수천억원의 제약비용이 발생하고 있기 때문에 제약을 완화시키기 위한 방안으로 배터리 에너지저장장치(BESS)를 적용하는 사업이 추진되고 있다. 이는 "발전제약완화 에너지저장장치(이하 발전제약완화용 ESS) 사업"으로 불리며 전국 19 개 변전소에 총 1.4GW(2C-Rate)의 에너지저장장치가 설치되는 국내 최대규모의 BESS 사업이다. 향후 송전망 확충에 의해서 발전제약이 해소되는 경우 주파수 조정용, 재생에너지 변동성 완화용 등의 다목적 ESS 로 활용될 계획이다. 본 보고서에서는 발전제약완화 ESS 사업의 기술적 효과를 실효치 기반의 시뮬레이션(PSS/E v33.3)을 통해서 검토하였다.

변전설비 감시제어시스템 메시지통합버스 개발에 관한 연구 (A Study on Development of Message Integration Bus for Supervisory Control And Data Acquisition)

  • 오도은;정남준;고종민;송재주;양일권
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 춘계학술발표대회
    • /
    • pp.830-832
    • /
    • 2008
  • 변전설비 감시제어시스템은 그 목적상 실시간의 대규모 측정정보 취득을 목적으로 한다. 취득정보는 RTU(Remote Terminal Unit)를 통해서 감시제어시스템에 전달된 후 필요에 따라 해당 정보를 요청하는 애플리케이션들에게 다시 전송된다. 현재 감시제어시스템에 널리 사용되는 DNP(Distribute Network Protocol)는 취득포인트 정보와 취득값만 가지고 있으므로 포인트 리스트에 대한 정보가 없는 경우에는 취득한 데이터를 판독할 수 없다. 따라서 감시제어시스템을 구축하기 위해 우선 RTU에 감시 선로정보를 입력하고, 이 정보를 다시 감시제어시스템의 DB에 포인트 정보와 매핑을 수행해야만 한다. 또한, 새로운 애플리케이션에서 취득값을 얻기 위해서는 이들 포인트 정보와 매핑 정보를 가지고 있는 감시제어시스템의 DB에 직접 연결해야만 한다. 본 논문은 공통정보모델과 이를 기반으로 작성된 메시지 교환 표준 인터페이스를 이용하여 감시제어시스템 취득정보의 효과적인 교환이 가능한 메시지 통합버스에 대하여 기술한다.

송변전 변압기 자산관리를 위한 수명손실 계산 (Lifetime Loss Calculation for Asset Management of a Power Transformer)

  • 이온유;이홍석;전상수;정민경;강형구
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.70-74
    • /
    • 2018
  • Social infrastructure such as production, transportation, gas, and electrical facilities would be degraded according to time and those facilities might need more maintenances, repairing, and management as time goes by. Especially, in the case of a power transformer, it is important to diagnose the transformer in order to avoid malfunction and failure because they could cause enormous damage. The economic as well as technical aspects of a transformer management must be considered while it is operated. Therefore, the concept of asset management should be applied as an advanced method of transformer management. Asset management refers to a series of processes to make a plan of maintenance and conservation of a power transformer considering the soundness, investment cost, and importance of equipment. It is important to apply the asset management considering calculation of a lifetime loss. In this paper, the lifetime loss calculation method of asset management for a power transformer is suggested.

25.8kV 친환경절연 개폐장치 실계통 적용 방식 및 고장사례 연구 (A Study on fault cases of 25.8kV Environment-friendly Insulated Switchgear and its its application to real power system)

  • 최상철;조필훈;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.189-190
    • /
    • 2011
  • 현재 변전소에서 일반적으로 사용되는 송변전기기 개폐장치인 GIS(GAS Insulated Switchgear)는 절연확보를 위해 외함 내부에 SF6 GAS가 충진되는 구조이다. SF6 GAS는 지구온난화 규제 물질에 해당하는 가스로 아크 및 부분방전 등에 의해 유독물질로 분해되는 특징이 있어 개폐장치의 내부 절연물로 친환경 매질로의 전환이 절실한 실정이다. 최근 KEPCO는 25.8kV GIS를 대체할 친환경절연 개폐장치를 도입하고 시범 운영중에 있으며, 그 결과에 따라 확대 적용할 방침이다.

  • PDF

송.변전설비 휴전조건에서 전력계통 안정운영방안 검토 (The Change of Power System Reliability During the Scheduled Outage of Transmission Facilities)

  • 이창근;이운희;주행로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.229-230
    • /
    • 2007
  • 전력계통을 구성하고 있는 모든 설비들이 항상 운전 가능한 상태에 있지는 않다. 이는 설비들이 일상적인 유지보수를 위해 정지되기도 하고, 과열 등 이상 징후를 발견하여 사전 정비를 위해서 정지되기도 하기 때문이다. 또한 인근 설비의 신중설이나 계통 구성의 변경을 목적으로 정지되기도 한다. 이 처럼 예기치 못한 고장에 의해서가 아닌 의도적인 목적으로 설비를 정지시키는 것을 휴전이라고 하고, 해당 설비의 휴전조건을 반영한 단기간의 관련 계통에 대한 운영방안을 수립하는 것이 휴전검토이다. 한편, 전력계통 계획단계에서는 설비의 휴전상태를 별도로 고려하지 않기 때문에 많은 경우 휴전이 시행되는 지역은 당초의 계통운영방안에 비하여 취약한 계통 조건이 형성되고 있다. 본 논문은 실계통 사례를 중심으로 이와 같은 설비의 휴전 특히, 발전소 인출선로 및 근단위 휴전으로 인한 과도안정도와 과부하 측면에서 계통 취약성 심화 정도를 보이고, 이어서 이들 문제점을 해소하긴 위한 방안과 그 비용을 간략히 계산하여 제시하고자 한다.

  • PDF

대용량 기업고객 전력공급체계 개선을 통한 친기업 환경조성 방안 연구 (Study on improvement of business friendly environment about power energy supply system for industrial customers)

  • 오재신;송호승;손광목;한통근;백우기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.355_356
    • /
    • 2009
  • 대용량 고객의 전용선로는 건설을 고객이 하고, 유지보수 책임 또한 고객에게 있어, 잦은 전용선로 고장 및 변전소 정전시 대규모 손실 발생하는바, 대용량 기업고객과 한전간의 전력공급서비스체계를 분석하고, 문제점 파악 및 해외사례 조사를 통해 개선방안을 도출하고, 개선방안과 관련한 구체적인 Action Plan을 제시하여 최적의 전력인프라 구축과 효율적인 전기공급을 통해 친기업 환경을 조성하고 고객설비 신뢰도 향상을 통한 정전 및 고장시간 감소로 사회적인 손실을 최소화하여 국가경쟁력 제고에 기여코자 한다.

  • PDF

변전소 내 주변압기 사고 발생 시 배전계통 연계점 이동을 통한 복구 알고리즘 (A Restoration Algorithm using Moving the tie Switch in Distribution System in case of Fault Occur in Power system Substation MTR)

  • 홍준호;이승재;최면송;임일형;김태완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.159_160
    • /
    • 2009
  • In this paper proposes a new algorithm of efficiency outage restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads.