• Title/Summary/Keyword: 손 치수

Search Result 55, Processing Time 0.021 seconds

Adiabatic Optical-fiber Tapers for Efficient Light Coupling between Silicon Waveguides and Optical Fibers (실리콘 도파로와 광섬유 사이의 효율적인 광 결합을 위한 아디아바틱 광섬유 테이퍼)

  • Son, Gyeongho;Choi, Jiwon;Jeong, Youngjae;Yu, Kyoungsik
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.5
    • /
    • pp.213-217
    • /
    • 2020
  • In this study we report a wet-etching-based fabrication method for adiabatic optical-fiber tapers (OFTs), and describe their adiabaticity and HE11 mode evolution at a wavelength of 1550 nm. The profile of the fabricated system satisfies the adiabaticity properties well, and the far-field pattern from the etched OFT shows that the fundamental HE11 mode is maintained without a higher-order mode coupling throughout the tapers. In addition, the measured far-field pattern agrees well with the simulated result. The proposed adiabatic OFTs can be applied to a number of photonic applications, especially fiber-chip packages. Based on the fabricated adiabatic OFT structures, the optical transmission to the inversely tapered silicon waveguide shows large spatial-dimensional tolerances for 1 dB excess loss of ~60 ㎛ (silicon waveguide angle of 1°) and insertion loss of less than 0.4 dB (silicon waveguide angle of 4°), from the numerical simulation. The proposed adiabatic coupler shows the ultrabroadband coupling efficiency over the O- and C-bands.

Fabrication of Silane-crosslinked Proton Exchange Membranes by Radiation and Evaluation of Fuel Cell Performance (방사선을 이용한 실란 가교구조의 유/무기 복합 수소이온 교환막 제조 및 연료전지 성능 평가)

  • Lee, Ji-Hong;Sohn, Joon-Yong;Shin, Dong-Won;Song, Ju-Myung;Lee, Young-Moo;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.525-530
    • /
    • 2012
  • In this study, silane-crosslinked organic/inorganic composite membranes were prepared by simultaneous irradiation grafting of binary monomer mixtures (styrene and 3-(trimethoxysilyl)propyl methacrylate (TMSPM)) with various compositions onto a poly(ethylene-alt-tetraethylene) (ETFE) film and followed by sol-gel processing and sulfonation to provide a silane-crosslinked structure and a proton conducting ability, respectively. The Fourier transform infrared spectroscopy (FTIR) and thermo gravimetric analysis (TGA) were utilized to confirm the crosslinking of ETFE-g-PS/PTMSPM films. The prepared membranes with similar ion exchange capacity but a different TMSPM content were selected and their membrane properties were compared. The ETFE-g-PSSA/PTMSPM membranes were characterized by water uptake, dimensional stability, and proton conductivity after sulfonation. The membrane electrode assemblies (MEA) of the prepared membranes were fabricated and their single cell performances were measured.

Initial changes of dental plaque, gingivitis and decalcification in Korean orthodontic patients with fixed appliance (한국인 고정식 교정 환자의 치태, 치은염 및 탈회의 초기 변화에 관한 연구)

  • Kang, Kook-Jin;Shon, Byung-Hwa
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.361-374
    • /
    • 1999
  • Intraoral filled type of orthodontic appliance can cause reversible or irreversible damages such as gingivitis, periodontitis, enamel decalcification, dental caries, root resorption, and pulpal changes. Such adverse effects are brought by increase in dental plaque as well as oral flora. Such an increase causes gingival inflammation and enamel decalcification. The purpose of this study is to get klowledge on initial changes in dental plaque, gingivitis, and enamel decalcification after bonding fixed orthodontic appliances according to time flow, gender, and sides(right/left) of premolar region. For control group, 48 students of dental college, Yonsei university(26 males, 22 females) were chosen; for experimental group, 73 orthodontic patients(36 males, 37 females) who will be treated with fixed appliances were chosen. All the subjects had no systemic disease, juvenile periodontitis and all the females had passed their ,menarche. Tooth brushing instruction was given to all the subjects prior to the experiment. For control group, plaque index, gingival index, and decalcification index were measured twice at 3 weeks interval ; for experimental group, the same was done prior to, 3, 6, 9 weeks after bonding fixed appliances. The following results were obtained: 1. In plaque index 3 weeks after placement of appliances, and it showed gradual increase afterwards. 2. In gingival index3 weeks after placement of appliances, and afterwards it showed increase at a faster rate than plaque index. 3. Enamel decalcification began to show between 3 and 6 weeks after bonding fixed appliances. Decalcification index began to increase 6 weeks after appliance placement, but there was no statistical significance. 4. When the comparison was made between two sides of premolar region, the right side showed greater index in plaque and gingival index of experimental group.

  • PDF

Care Labels and Consumer's Care Behavior of Hat Products (모자제품의 레이블과 소비자 관리행동)

  • Kim, Cha-Hyun;Park, Myung-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.12
    • /
    • pp.1784-1792
    • /
    • 2007
  • This study set out to identify the problems with hat labels and to search for improvement measures by examining and analyzing consumers' practice of managing their hats. It also intended to provide accurate and enough information about how to keep and wash hats and thus help consumers use their hats for a long period. In an attempt to investigate how consumers wash and manage their hats, a survey was carried out to 395 individuals in their twenties and over who owned hats living in urban areas including Seoul, and were quota sampled according to age and gender. The survey period is March to April 2007. The collected data were statistically treated with the SPSS 12.0 program in terms of frequency, percentage, mean, standard error, cross tabulation, t-test, and one-way ANOVA. The findings were as followed. First, the respondents were in the average level of perceiving and practicing the washing methods of their hats. The female respondents who had more experiences with laundering than the males knew and practiced the washing methods for hats better than males. Second, compared to other clothing items, hat wearers were more likely to pay careful attention to their hats by putting their hats in a laundry net and applying a laundry detergent for wool fabrics when using a washing machine or washing their hats with their own hands. And third, most of the hat wearers were aware of the importance of hat labels and showed a lower level of trust in them than other clothing items. The suppliers need to offer accurate and practical labels in order to regain the consumers' trust. Many consumers had some difficulties figuring out the size system of hats. In particular, the male consumers had a low level of perception of labels, which implies that there should be specific efforts to educate them about general labels.

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).