• Title/Summary/Keyword: 손실수두

Search Result 93, Processing Time 0.021 seconds

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

The Comparative Study of Flood Inundation Analysis Systems for Urban Area Using GIS (GIS를 이용한 도시 침수분석 시스템의 비교 연구)

  • Ryu Jae-Hyun;Min Sang-Gi;Roh Jae-Sik;Lee Kil-Choon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.840-844
    • /
    • 2005
  • 최근 기상이변에 따라 특정지역에 단시간의 집중호우에 의한 홍수가 빈번히 발생하고 있으면, 이에 따른 위험과 손실이 증가하고 있다. 집중호우 발생시 단지설계 및 배수체계 부분에 관련하여 도출되는 가장 중요한 문제점 중의 하나는 배수시스템의 배수불량으로 인한 단지 내수침수문제라 할 수 있다. 기존 지역 배수시스템의 설계빈도는 20년을 넘지 못하고 있는 실정이나 집중호우는 이를 상회하므로 국부적인 단지내 배수시스템 불량은 피할 수 없는 현상이다. 하지만 기존의 배수시스템 설계기법은 합리식을 기본으로 하는 정적개념의 설계 기법이므로 국부적인 배수시스템의 손실수두 발생에 의한 국지적 침수 양상을 파악하기는 부적절하다. 본 논문에서는 과거 집중호우로 인해 피해가 발생했던 중랑천 유역 중 침수가 자주 발생했던 중랑구를 대상유역으로 결정하였다. SWMM, ILLUDAS 모형을 이용하여 대상유역에 대한 유출 해석을 실시한 결과 도시유역에서는 SWMM 모형이 그 적용성에 있어서 다소 효과적인 것으로 나타났다. 도시유출모형을 GIS와 연계하기 위하여 지형공간데이터를 구축하고 GIS 도구인 Arc/Info와 ArcView를 이용하여 연계하는 방안을 제시하였으며, 유출모형의 결과값을 이용하여 침수구역도를 작성하였다. GIS와 연계시 실제 침수가 예상되는 범위을 가시화함으로써 침수발생지점을 사전에 예측할 수 있고 침수예방을 위한 기초자료로 활용할 수 있을 것으로 판단된다.

  • PDF

유공Caisson식 방파제에 작용하는 파력에 관한 연구

  • 안수한;편종근
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1980.08a
    • /
    • pp.44-46
    • /
    • 1980
  • 파의 에너지 감쇠기구의 관점에서 볼 때 분류손실방식인 유공벽식 방파제 중에서 원형공이 벽 전체에 균일하게 분포되어 있고 구멍 직경에 비해 벽 두께가 얇은 삼중 유공벽형 Caisson의 각 벽에 작용하는 파력에 고나해 이론적 접근과 실험을 통한 실증을 시도해 보았다. 이론적인 방법으로는 토굴구효남의 이론을 응용하였으며 주어진 파랑조건에 대해 각 유공벽 전 후면에 연속방정식과 Bernoulli 방정식을 이용하여, 각 영역별 연속 Potential의 진폭과 위상각에 대한 비선형 12원 연립방정식을 만들었고 Computer를 이용하여 반복법으로 각 속도 Potential을 확정하였다. 이렇게 구한 속도 Potential을 압력방정식에 대입하여 각 벽별 파력을 계산하였으며 동일한 파랑조건하의 실험에서 각 벽별 파력을 측정하여 양자를 서로 비교검토하였다. Bernoulli의 방정식중 에너지 손실항은 의사비선형으로 처리하였다. 유공율조합 0.25-0.3-0.2이고, 판두께가 1cm인 모형의 실험결과, 각 벽별 최대파력치의 특성으로서는 첫때, S-2, S-3등 간벽에 작용하는 파력이 전벽 및 후벽에 비해 두드러지게 작다는 사실과, 둘째 작용파력의 크기 순이 파형경사가 작을 때는 대략 S-4, S-1, S-2, S-3순이고 파형경사가 클 때에는 대략 S-1, S-4, S-2, S-3순이라는 점 등을 들 수 있겠다. 굴구효남이 가정한 f의 치 1.5를 사용하여 계산한 각 벽별 최대파력을 실험치와 비교해 본 결과, 파가 각 유공벽을 통과할 때의 손실수두를 실험에서의 양만큼 fr=1.5를 가정한 수학적 model이 설명해 주지 못한다고 볼 수 있으므로 두가지 방법에 의하여 본 실험에서 사용한 유공판의 손실계수를 근사적으로 추정하여 보았다. 추정한 f를 사용하여 다시금 각 벽별 최대파력을 계산하고 실험치와 비교해 보면 훨씬 서로 근접함을 알 수 있었다. 결국 본 논문의 이론을 사용하면 유공Caisson문제의 전체적인 윤곽 및 각 변수들의 파력에 대한 영향을 파악할 수 있겠다.

  • PDF

Development of a quantification method for modelling the energy budget of water distribution system (상수관망 에너지 모의를 위한 정량화 분석기법 개발)

  • Choi, Doo Yong;Kim, Sanghyun;Kim, Kyoung-Pilc
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1223-1234
    • /
    • 2022
  • Efforts for reducing greenhouse gas emission coping with climate change have also been performed in the field of water and wastewater works. In particular, the technical development for reducing energy has been applied in operating water distribution system. The reduction of energy in water distribution system can be achieved by reducing structural loss induced by topographic variation and operational loss induced by leakage and friction. However, both analytical and numerical approaches for analyzing energy budget of water distribution system has been challengeable because energy components are affected by the complex interaction of affecting factors. This research drew mathematical equations for 5 types of state (hypothetical, ideal, leak-included ideal, leak-excluded real, and real), which depend on the assumptions of topographic variation, leakage, and friction. Furthermore, the derived equations are schematically illustrated and applied into simple water network. The suggested method makes water utilities quantify, classify, and evaluate the energy of water distribution system.

A Study on the Component Design for Water Network Analysis (상수도 관망해석 컴포넌트 설계에 관한 연구)

  • Kim, Kye-Hyun;Kim, Jun-Chul;Park, Tae-Og
    • Journal of Korea Spatial Information System Society
    • /
    • v.2 no.2 s.4
    • /
    • pp.75-84
    • /
    • 2000
  • GIS has been building for various application fields with the aids of NGIS project, especially numerous municipal governments are building a UIS in the level of local governments' informatization. Although there are some difference between municipal governments' business, still many things are in common. So far, individual municipal governments have developed a UIS for their own use, which lead to duplicated development of the UIS. The component technology has been introduced to remove such duplicated efforts and it enabled maximizing the reusablilty of the UIS already developed. This paper proposes a component design for network analysis of the drinking water to calculate the amount of flow and the head loss. This component design provides the initial water amount to estimate the amount of the network flow and the head loss, thereby supports the decision making such as installation or extension of the pipe network. The process of the component design accompanies the business reengineering to support the standardized business work flow. Also, the design of the network analysis component uses the algorithms induced with UML specification. Based on the component design, the component development has been progressing and the network analysis system would be followed. In the near future, another component to integrate the network analysis and the business related to the drinking water needs to be developed.

  • PDF

On the Viscous Flow Around Breaking Waves Generated by a Submerged Cylinder(Part 2 : Aspects of Viscous Flow) (몰수실린더에 의하여 생성되는 쇄파주의 점성유동의 고찰(제2부: 점성유동특성))

  • B.S. Hyun;Y.H. Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • The present paper is Part 2 of three-part paper for an experimental study on breaking waves generated by a submerged cylinder. Measurements of velocity and head loss profiles at the wakes of cylinder and breaker as well as the turbulent intensities in breaking region were made to elucidate the viscous aspects of breaking waves. Their mutual correlation is also investigated. It is found that the head loss profile is an excellent indicator of the strength and extent of breaker. Very high turbulent intensities measured at and just downstream of the breaker indicate the consequence of energy transfer of wave breaking into turbulence.

  • PDF

Integrated Method to Determine the Sphericity of Filter Media (여과지에서 여재 원형도 결정 방법에 대한 연구)

  • Cheong, Won-Suk;Choi, Suing-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.565-571
    • /
    • 2005
  • The method to decide media sphericity on the filter has been investigated. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media affecting the bed expansion during backwash. The media in each treatment plant may have different sphericity, and the sphericity of the media in the filter may be changed as backwashing has been conducted regularly for a long time. Media from twelve water treatment plants under KOWACO have been collected and selected to insure various and practical sphericities. The sphericity of each media has been calculated by using well known equations. For example, Kozeny equation, Dahmarajah equation and so on. The experiment results have indicated that the sphericity of each water treatment plant is different. Although the sphericity values measured by different methods were turned out to be diverse values, the order in the magnitude seemed to be the same. The sphericity values of sand media were in the range of 0.71-0.82 and those of anthracite were placed between 0.49 and 0.56 by the Dharmarajah equation.

화력발전소 CWD(Cooling Water Discharge)를 활용한 해양소수력 개발의 기술적인 고찰(화력발전소 CWD와 조위특성과의 Harmony)

  • Eom, Bok-Jin
    • 열병합발전
    • /
    • s.69
    • /
    • pp.15-20
    • /
    • 2009
  • 소수력 계획 시 개발지점에 대하여 수많은 자료와 정보 등을 필요로 하게 되는데 특히 해당지역내의 유량분포에 대한 유황자료는 개발의 판단여부를 결정케 하는 중요한 요소이다. 소수력발전소의 설비용량에 직접 관계되는 설계유량의 결정과 재해방지를 위한 유출의 예측을 가능케 하고 발전소운영 시 가동률 및 경제성에도 직접적인 영향을 미치는 중용한 요소이나 여기서 논하는 소수력개발은 하천이나 댐과 같은 유형이 아니라 일정한 유량을 확보하여 배출하기 때문에 문제는 없다. 그러나 계절별 부하에 따른 냉각수량의 변화 및 소수력 발전유량의 변동, 조위(해수면) 변화 등에 따라 달라진다. 그러므로 수위조절을 위한 수문은 이들의 변화에 따라 자동운전이 가능해야 하지만 운전시 발전정격수위를 맞출 수 있도록 수문을 조절한 다음 Turbine Governor에 의해 유량 및 수위를 제어할 수 있도록 설계하여 냉각수 순환수 계통에 영향이 미치지 않게 언제나 적정수위를 유지시킬 수 있는 운전모드로 구축하는 것이 안정이라 볼 수 있다. 소수력발전설비 및 수문의 오작동 및 고장이 발생할 때 수위가 상승하여 냉각계통에 손실수두 증가, 취수펌프의 양정고 증가와 Surge 발생 등으로 발전소의 정상 운전에 미치는 영향이 없어야 하므로 세밀한 검토가 필요하기 때문에 폐쇄시간과 수압상승 값 등 요인 분석후 설계하여야 한다. Figure A와 같이 국내 화력발전단지에서 냉각수로 사용되고 방류되는 해수는 발전소에 따라 ca.70~150 CMS로 ca.2,000~5000 kW 이상의 수력에너지(H=4m 형성 기준)를 보유하고 있으나, 현재 활용되지 못하고 그대로 해양으로 방류되고 있어 이 수력에너지의 개발 방안을 오래전부터 검토하여 왔다. 발전소 온배수의 원활한 배수를 위한 설계 낙차와 함께 남서해안의 조위변화에 따른 낙차를 이용하는 것으로 소수력 발전 방식과 조력발전 방식의 특징을 동시에 활용할 수 있다.

  • PDF

The Effects of Anthracite Media Sphericity on Filtration Efficiency (안쓰라사이트 여재 원형도가 여과 효율에 미치는 영향)

  • Cheong, Won-suk;Choi, Suing-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.763-770
    • /
    • 2007
  • There are many design parameters affecting filtration efficiency such as filteration rate, media packing depth, size distribution, and so on. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media. The effect of sphericity on the performance of anthracite filter has been investigated. Media from eight water treatment plants have been collected. The sphericity of each media has been calculated by using well known headloss equations such as Kozeny equation, Dahmarajah equation etc.. Columns packed with anthracite media having different sphericity have been used to compare headloss development, floc accumulation in the bed, particles in bed water, filtrate turbidities after backwash and so on. The repeated experiments have indicated that the sphericity of anthracite media may not have remarkable influence on the filter performance as it has been suspected. It also has been prospected in the experiment that the media of higher sphericity would store more particles in the bed and give better filtrate quality, if provided that the effective size and the size distribution of media would be the same.

Comparison of the filtration performance by different media in pretreatment of seawater desalination by reverse osmosis (여재 종류에 따른 역삼투법 해수담수화 시설 전처리 여과공정의 성능비교)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.215-222
    • /
    • 2009
  • This study compares the performance of the filters with various media in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is used as raw water. The filter performance is evaluated by the filtrate quality and the head loss development. Five media is selected in this study: anthracite, $Filtralite^{(R)}$, sand, Pumice, $AFM^{(R)}$. These media are used in combination for dual media filter and alone for mono media filter. The comparison results show that NC0.8-1.6 is the best $Filtralite^{(R)}$. The dual media filter of NC0.8-1.6 and sand outperformed other filters in particle removal. The dual media filter of anthracite and sand showed good performance in organic removal. The mono media filter of Pumice produced the similar filtrate quality as the mono media filter of sand although the effective size of Pumice is considerably greater than that of sand. Due to big size, head loss development is maintained slow in the filtration of Pumice.