• Title/Summary/Keyword: 손상 측정

Search Result 2,152, Processing Time 0.028 seconds

Seminal Tumor Necrosis Factor-alpha Level and Sperm Nuclear DNA Integrity in Healthy Donors (정액 내 Tumor Necrosis Factor-alpha 농도와 정자 DNA 손상과의 관련성)

  • Kim, Hyun-Jun;Jee, Byung-Chul;Moon, Jeong-Hee;Lee, Jung-Ryeol;Suh, Chang-Suk;Kim, Seok-Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.1
    • /
    • pp.35-43
    • /
    • 2009
  • Objectives: Seminal concentration of tumor necrosis factor-alpha (TNF-${\alpha}$) relevant to sperm nuclear DNA integrity has not been studied. The present study aimed to evaluate seminal concentration of TNF-${\alpha}$ in correlation with sperm parameters and nuclear DNA integrity in asymptomatic healthy donors. Methods: Semen samples were obtained by masturbation from forty-five healthy donors. Results: Sperm quality was assessed by computer-assisted semen analysis and nuclear DNA integrity measured by the TUNEL assay in raw semen. TNF-${\alpha}$ concentrations were measured by ELISA in frozen-thawed seminal plasmas. Sperm DNA fragmentation rates were ranged between 1.9% and 53.0% (mean${\pm}$SD, 12.4${\pm}$9.6%). Univariate analysis revealed that DNA fragmentation rate was not associated with sperm concentration or motility but had a correlation with linearity negatively (r=-0.325, p=0.03) and age positively (r=0.484, p=0.001). The mean seminal concentration of TNF-${\alpha}$ was 4.9 pg/mL with a range from 1.1 to 22.6 pg/mL. The TNF-${\alpha}$ concentration had no correlation with clinically relevant parameters of sperm quality or nuclear DNA fragmentation rate. Conclusion: Our results indicate that sperm nuclear DNA fragmentation may be not associated with seminal TNF-${\alpha}$ level or sperm quality in asymptomatic healthy donors.

New Statistical Pattern Recognition Technology for Condition Assessment of Cable-stayed Bridge on Earthquake Load (지진하중을 받는 사장교의 상태평가를 위한 새로운 통계적 패턴 인식 기술)

  • Heo, Gwanghee;Kim, Chunggil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.747-754
    • /
    • 2014
  • In spite of its usefulness for health monitoring of structures on steady external load, the statistical pattern recognition technology (SPRT), based on Mahalanobis distance theory (MDT), is not good enough for the health monitoring of structures on large variability external load like earthquake. Damage is usually determined by the difference between the average measured value of undamaged structure and the measure value of damaged one. So when external variability gets larger, the difference gets bigger along, which is thus easily mistaken for a damage. This paper aims to overcome the problem and develop an improved Mahalanobis distance theory (IMDT), that is, a SPRT with revised MDT in order to decrease external variability so that we will be able to continue to monitor the structure on uncertain external variability. This method is experimentally tested to see if it precisely evaluates the health of a cable-stayed bridge on each general random load and earthquake load. As a result, the IMDT is found to be valid in locating structural damage made by damaged cables by means of data from undamaged cables. So it is proved to be effectively applicable to the health monitoring of bridges on external load of variability.

Neutrophilic Respiratory Burst Contributes to Acute Lung Leak in Rats Given N-nitroso-N-methylurethane (N-nitroso-N-methylurethane으로 유도된 급성 폐손상에서 호중구에 의한 산화성 스트레스의 역할)

  • Kim, Seong-Eun;Kim, Dug-Young;Na, Bo-Kyung;Lee, Young-Man
    • Applied Microscopy
    • /
    • v.33 no.1
    • /
    • pp.1-16
    • /
    • 2003
  • As is well known that N-nitroso-N-methylurethane (NNNMU) causes acute lung injury (ALI) in experimental animals. And ALI caused by NNNMU is very similar to ARDS in human being in its pathology and progress. In its context, we investigated the pathogenetic mechanism of ARDS associated with oxidative stress by neutrophils in Sprague-Dawley rat model of NNNMU-induced ALI. NNNMU had increased lung weight/body weight ratio (L/B ratio), lung myeloperoxidase (MPO) activity, protein content and number of neutrophils in bronchoalveolar fluid (BALF) compared with those of control rat (p<0.001, respectively). In contrast, the amount of pulmonary surfactant in BALF was decreased by NNNMU (p<0.001). Morphologically, light microscopic examination denoted pathological findings such as formation of hyaline membrane, infiltration of neutrophils and perivascular cuffing in the lungs of NNNMU-treated rats. In addition, ultrastructural changes such as the necrosis of endothelial cells, swelling and vacuolization of lamellar bodies of alveolar type II cells, and the degeneration of pulmonary surfactant were identified after treatment of NNNMU. Very interestingly, cerium chloride electron microscopic cytochemistry showed that NNNMU had increased the production of cerrous-peroxide granules in the lung, which signified the increased production of hydrogen peroxide in the lung. Collectively, we conclude that NNNMU causes acute lung leak by the mechanism of neutrophilic oxidative stress of the lung.

Effective Biomarkers for Miniature Pig in Acute Kidney Injury Using Renal Ischemia-Reperfusion Model (미니돼지의 신허혈-재관류에 의한 급성신손상 모델에서의 유용한 바이오마커)

  • Kim, Se-Eun;Shim, Kyung-Mi;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.372-376
    • /
    • 2012
  • Acute kidney injury (AKI) is a serious problem associated with high morbidity and mortality. Ischemia-reperfusion is an important cause of acute kidney injury. This study was performed to ascertain clinically useful biomarkers for the diagnosis of AKI. In three miniature pigs, AKI were induced by 60 minutes of bilateral renal ischemia by the clamping renal artery. Blood and urine samples were collected from the pigs prior to clamping (baseline) and 0, 1, 3 and 5 days post-clamping. Serum blood urea nitrogen (BUN), creatinine, sodium and uric acid were measured in serum and urine samples. Fractional excretion of sodium ($FE_{Na}$) and fractional excretion of uric acid ($FE_{UA}$) were calculated. Also, interleukin (IL)-6, IL-18, liver type fatty acid binding protein (L-FABP) and glutathione-S-transferase (GST) were detected by Western immunoblotting. Serum BUN and creatinine levels were increased significantly at day 1 post-clamping in all three miniature pigs. However, $FE_{Na}$ and $FE_{UA}$ showed marked individual differences. Western immunoblotting revealed significantly increased levels of IL-6, IL-18, L-FABP and GST in post-ischemic urine, compared to pre-clamping. While more research concerning the variance of $FE_{Na}$ and $FE_{UA}$ is needed, serum BUN, creatinine, IL-6, IL-18, L-FABP and GST may be sensitive urine biomarkers for diagnosis of AKI together with other biomarkers in the porcine ischemia-reperfusion model.

Effect of Heat Stress of Extreme Heat Lever on Muscle functionand Muscle Injury Markers in Elderly Women (열 스트레스가 여성노인들의 근기능 및 근손상에 미치는 영향)

  • Park, Sok;Lee, Chone Ho;Back, Seung Ok;Shin, Yong Up;Kim, Jung Suk;Cho, Young Wung;Lee, Young Jun
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.793-802
    • /
    • 2010
  • The purpose of this study was to examine the influence of extreme heat on muscle function and muscle injury marker in elderly women. The subjects of this study were eight post-menopausal elderly women without any metabolic disease. All eight subjects were asked to perform the knee joint isokinetic exercise using isokinetic equipment (cybex) in the laboratory and experimental temperature within laboratory was adjusted to two conditions: extreme heat temperature(33±0.5℃) and normal temperature(20±0.5℃) maintained in 50±3% humidity conditions. Each experimental exercise was monitored and analyzed the change of HSP70, LDH and CK. Muscular functions (peak torque, total work, percentage of peak torque body weight, fatigue index, average power and total work) were significant differences at exercise between temperatural conditions (p<.05). In extreme heat temperature, muscular injury markers (HSP70, LDH and CK) were increased, threfore resulted in significantly higher than normal temperature(p<.05). These results show that extreme heat temperature can decrease muscle function in elderly women.

Quantitative Damage Index of RC Columns with Non-seismic Details (비내진상세를 가지는 철근콘크리트 기둥의 정량적 손상도 평가 기준)

  • Kim, Kyung-Min;Oh, Sang-Hoon;Choi, Kwang-Yong;Lee, Jung-Han;Park, Byung-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.11-20
    • /
    • 2013
  • In this paper, the quantitative damage index for reinforced concrete (RC) columns with non-seismic details were presented. They are necessary to carry out the postearthquake safety evaluation of RC buildings under 5 stories without seismic details. The static cyclic test of the RC frame sub-assemblage that was an one span and actual-sized was first conducted. The specimen collapsed by the shear failure after flexural yielding of a column, lots of cracks on the surfaces of columns and beam-column joints and the cover concrete splitting at the bottom of columns occurred. The damage levels of these kinds of columns with non-seismic details were classified to five based on the load-displacement relationship by the test result. The residual story drift ratios and crack widths were then adapted as the quantitative index to evaluate the damage limit states because those values were comparatively easy to measure right after earthquakes. The highest one among the residual story drift ratios under the similar maximum story drift ratio decided on the residual story drift ratio of each damage limit state. On the other hand, the lowest and average ones among the respective residual shear and flexural widths under the similar maximum story drift ratio decided on the residual shear and flexural widths of each damage limit state, respectively. These values for each damage limit state resulted in being smaller than those by the international damage evaluation guidelines that are for seismically designed members under the same deformations.

Hybrid Structural Health Monitoring of Steel Plate-Girder Bridges using Acceleration-Impedance Features (가속도-임피던스 특성을 이용한 강판형교의 하이브리드 구조건전성 모니터링)

  • Hong, Dong-Soo;Do, Han-Sung;Na, Won-Bae;Kim, Jeong-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.61-73
    • /
    • 2009
  • In this paper, hybrid health monitoring techniques using acceleration-impedance features are newly proposed to detect two damage-type in steel plate-girder bridges, which are girder's stiffness-loss and support perturbation. The hybrid techniques mainly consists of three sequential phases: 1) to alarm the occurrence of damage in global manner, 2) to classify the alarmed damage into subsystems of the structure, and 3) to estimate the classified damage in detail using methods suitable for the subsystems. In the first phase, the global occurrence of damage is alarmed by monitoring changes in acceleration features. In the second phase, the alarmed damage is classified into subsystems by recognizing patterns of impedance features. In the final phase, the location and the extent of damage are estimated by using modal strain energy-based damage index method and root mean square deviation (RMSD) method. The feasibility of the proposed hybrid technique is evaluated on a laboratory-scaled steel plate-girder bridge model for which hybrid acceleration-impedance signatures were measured for several damage scenarios. Also, the effect of temperature on the accuracy of the impedance-based damage monitoring results are experimentally examined from combined scenarios of support damage cases and temperature changes.

Identification of Impact Damage in Smart Composite Laminates Using PVDF Sensor Signals (고분자 압전센서 신호를 이용한 스마트 복합적층판의 충격 손상 규명)

  • Lee, Hong-Young;Kim, In-Gul;Park, Chan-Yik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.51-59
    • /
    • 2004
  • An experimental procedure to identify failure modes of impact damage using sensor signals and to analyze their general features is examined. A series of low-velocity impact tests from low energy to damage-induced high energy were performed on the instrumented drop weight impact tester to monitor the stress wave signals due to failure modes such as matrix cracking, delamination, and fiber breakage. The wavelet transform(WT) and Short Time Fourier Transform(STFT) are used to decompose the piezoelectric sensor signals in this study. The extent of the damage in each case was examined by means of a conventional ultrasonic C-scan. The PVDF sensor signals are shown to carry important information regarding the nature of the impact process that can be extracted from the careful signal processing and analysis.

The Measurement and Analysis for Ultraviolet Radiation (자외선복사의 측정과 분석)

  • Han, Jong-Sung;Kim, Hong-Bum;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.7-12
    • /
    • 2005
  • When a light is projected upon a material, part of its radiant energy is absorbed and the rest is reflected or transmitted according to the nature of the material. The molecules of the substance absorbing a light obtains the radiant energy to make thermal reactions or photochemical reactions. Specially, photochemical reactions by ultraviolet(UV) radiation brings about photochemical degradation such as color change. Because the photochemical damage brings about a devaluation of material and once damaged, it is irretrievable, it is necessary to minimize the damage and conserve the native quality of a material by a protective lighting system. This paper presents the measurement and photochemical damage for UV radiation from light sources. We measured the optical radiations from artificial light sources and daylight, and we analyzed a functional relation between irradiance and UV radiation form the results.

플라즈마 이온주입(Plasma Immersion Ion Implantation, PIII) 방법으로 Boron 도핑된 실리콘 기판의 도펀트 활성화와 기판손상에 관한 연구

  • 이기철;유정호;고대홍;강호인;김영진;김재훈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.184-184
    • /
    • 1999
  • 반도체소자의 고집적, 미세화에 따라 MOSFET 소자에서의 고농도, 미세접합이 요구되고 있다. 이러한 고농도, 미세접합을 형성하기 위하여 기존의 저에너지 이온주입법을 대체 또는 병행할 목적으로 플라즈마 이온주입방법이 활발히 연구되고 있다. 본 연구에서는 플라즈마 이온주입방법을 이용하여 (100) 실리콘 기판에 보론을 주입후 열처리하여 형성된 p+층의 도펀트의 활성화와 이온주입으로 인한 실리콘 기판의 손상을 고찰하였다. 본 실험에서 (100)실리콘 기판에 도핑할 소스 가스로 BF3을 주입하고, D.C. pulse 플라즈마 도핑시스템을 사용하여 플라즈마 내의 보론이온을 웨이퍼 홀더에 -1~-5kV의 인가된 음전압에 의해 가속시키어 실리콘 웨이퍼에 주입하였다. 주입에너지 -1kV, -3kV, -5kV와 1$\times$1015, 3$\times$1515의 dose로 주입된 실리콘 기판을 급속가열방식(RTP)을 사용하여 $600^{\circ}C$~110$0^{\circ}C$의 온도구간에서 10초와 30초로 열처리하여 도펀트의 활성화와 미세접합을 형성한 후 SIMS, four-point probe, Hall 측정, 그리고 FT-IR을 이용하여 플라즈마 이온주입된 도펀트의 거동과 활성화율을 관찰하였고 FT-IR과 TEM의 분석을 통하여 이온주입으로 인한 실리콘 기판의 손상을 고찰하였다. SIMS, four-point probe, Hall 측정, 그리고 FT-IR의 분석으로 열처리 온도의 증가에 따라 도펀트의 활성화율이 증가하였고, 이온주입 에너지와 dose 그리고 열처리 시간의 증가에 따라서 주입된 도펀트의 활성화는 증가하였다. 그리고 주입에너지와 dose 그리고 열처리 시간의 증가에 따라서 주입된 도펀트의 활성화는 증가하였다. 그리고 주입에너지와 dose를 증가시키면 접합깊이가 증가함을 관찰하였다. 이온주입으로 인한 기판손상의 분석을 광학적 방법인 FT-IR과 미세구조를 분석할 수 있는 TEM을 이용하여 분석하였다. 이온주입으로 인한 dislocation이나 EOR(End Of Range)과 같은 extended defect가 없었고, 이온주입으로 인한 비정질층도 없는 p+층을 얻을수 있었다.

  • PDF