Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Contralateral Vesicoureteral Reflux in Children with Abnormal Unilateral Renal Development (일측성 신발생이상 환아에 동반된 반대측 방광요관역류)

  • Oh Sung-Wook;Lee Jae-Seung;Kim Myoung-Jun;Han Sang-Won;Bae Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.53-59
    • /
    • 1997
  • There have been many recent reports that unilateral renal agenesis and multicystic dysplastic kidneys are accompanied by contralateral vesicoureteral reflux leading to its injury. We grouped the children with unilateral renal agenesis, renal hypoplasia, multicystic dysplastic kidney into abnormal unilateral renal development and investigated whether it was accompanied with contralateral vesicoureteral reflux. We retrospectively reviewed 96 pediatric cases of unilateral renal agenesis, hypoplasia, multicystic dysplastic kidney diagnosed at Shinchon Severance Hospital, Yongdong Severance Hospital from 1987 to 1996 and Ajou University Hospital from 1994 to 1996. Diagnosis was based on radiological findings, renal hypoplasia being defined as small renal size with no apparent renal scarring and no irregularity of the calyceopelvic system on abdominal sonography or intravenous pyelography. Among the 96 cases,48 cases carried out voiding cystourethrography. 58 cases were male(60%) and 38 cases were female(40%). The cases of abnormal unilateral development on the left side were 45(47%) and that on the right side were 51(53%). Although there were diverse reasons leading to diagnosis, the major ones included were prenatal sonography, urinary tract infection, and other congenital anomalies. In cases of unilateral renal agenesis & hypoplasia the leading factors were urinary tract infection & other congenital anomalies and in cases of multicystic dysplastic kidney that was prenatal sonography. There was a chronological gap between the mean age of diagnosis(1.8 year) and voiding cystouerthrography(2.5 year, P < 0.01). 9 of the 18 unilateral renal agenesis cases, 5 of the 11 unilateral renal hypoplasia cases, and 3 of the 19 unilateral multicystic dysplastic kidney cases showed contralateral vesicoureteral reflux. Average reflux grade was above G III.Among the 17 children who had contralateral vesicoureteral reflux, 3 children had chronic renal failure and ureteroneocystostomy was carried out in 6 children. From the above results we conclude that screening voiding cystourethrography should be performed in children with abnormal unilateral renal development for early detection of vesicoureteral reflux in the contralateral kidney.

  • PDF

Physicochemical and Sensory Properties of Rice Stored in an Unused Tunnel (폐터널 저장 쌀의 이화학적 및 관능적 특성)

  • Moon, Gap-Soon;Kim, Mi-Jeong;Jin, Myung-Hee;Kim, Su-Yeon;Park, So-Young;Ryu, Bog-Mi
    • Korean journal of food and cookery science
    • /
    • v.26 no.2
    • /
    • pp.220-228
    • /
    • 2010
  • This study was designed to examine the effectiveness of an unused tunnel as a rice storage place. The physicochemical changes of rice grains were investigated during 8-months of storage in the tunnel located at Kyungnam province, Korea. Two kinds of tunnel stored rices, NP(rice grown with no pesticides) and LP(rice grown with less pesticides) were compared with $5^{\circ}C$ stored rice as a control. The peroxidase activities, as an index of freshness of rice grains, gradually decreased and NP appeared to be fresher than LP. Whiteness, grain wholeness, and chalkyness were less desirable for the tunnel stored rice than the control, with no significant difference of physicochemical properties, including the broken, damaged, colored rice, and contents of moisture, protein, and amylose. Palatability dropped below 70 in all three groups at later phase. The sensory evaluation showed that overall preference was slightly higher for the control but not significantly different from the other two groups. From all the evidences shown, unused tunnels may be an effective place for a long-term rice storage, since the average temperature inside the tunnel was maintained very constantly around $14.3^{\circ}C$ and relative humidity was optimal for rice storage, especially during spring and summer seasons.

A Leg Analysis on the Discharge of Cargo Residue at Sea (화물잔류물의 해양 투입처분(배출) 사안에 대한 법률적 분석)

  • Hong, Gi-Hoon;Park, Chan-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.193-202
    • /
    • 2006
  • The Consultative Meeting of the Convention on the Prevention of Marine Pollution by Dumping of Wastes and other matter, 1972 (London Convention 1972) has requested to International Maritime Organization (IMO) Marine Environmental Protection Committee to collaborate and help clarify a boundary issue between International Convention for the Prevention of Pollution from Shops, 1973 as modified by the Protocol of 1978 (MARPOL) and the London Convention concerning 'dumping' versus 'discharges' during normal operations of ships in 2004, and subsequently established a Joint London Convention/MEPC Correspondence Group. The Contracting Parties to London Convention expressed their environmental concerns on the broad interpretation of the "cargo-associated wastes" by the States, which could be discharged by ships under MARPOL. Regulatory regimes for the cargo residues appear to vary among states. Some countries require fur ships to discharge their cargo wastes into the port reception facility and IMO also recommends doing so. This paper examines the related current national and international legal texts for the regulation of disposal of wastes from ships in order to analyze the current global concern on the marine pollution associated with waste discharge during operations of ships. In particular, we attempt to evaluate the likely marine environmental consequences arising from the disposal of cargo residue using an hypothetical case for the coal cargo residue among bulk cargos in this paper, since location, magnitude and frequency of the discharge of coal cargo residues into the sea adjacent to Korean Peninsula are not readily available. The cargo residues may be discharged to the sea according to MARPOL 73/78; however, its marine environmental consequences can be significant depending upon the characteristics and amounts of wastes to be discharged. Also the public tolerance of the environmental consequences would be widely different among nations. Multilateral environmental agreements, in general, more strictly apply their rules if there are other options to disposal at sea, i.e. port reception facility in this case. Therefore, port reception facilities for the wastes generated by ships are recommended to be further constructed in major national ports in order to reduce the risk of environmental damages during the operations of ships.

  • PDF

Gait Analysis of a Pediatric-Patient with Femoral Nerve Injury : A Case Study (대퇴신경 손상 환아의 보행분석 : 사례연구)

  • Hwang, S.H.;Park, S.W.;Son, J.S.;Park, J.M.;Kwon, S.J.;Choi, I.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.165-176
    • /
    • 2011
  • The femoral nerve innervates the quadriceps muscles and its dermatome supplies anteromedial thigh and medial foot. Paralysis of the quadriceps muscles due to the injury of the femoral nerve results in disability of the knee joint extension and loss of sensory of the thigh. A child could walk independently even though he had injured his femoral nerve severely due to the penetrating wound in the medial thigh. We measured and analyzed his gait performance in order to find the mechanisms that enabled him to walk independently. The child was eleven-year-old boy and he could not extend his knee voluntarily at all during a month after the injury. His gait analysis was performed five times (GA1~GA5) for sixteen months. His temporal-spatial parameters were not significantly different after the GA2 or GA3 test, and significant asymmetry was not observed except the single support time in GA1 results. The Lower limb joint angles in affected side had large differences in GA1 compared with the normal normative patterns. There were little knee joint flexion and extension motion during the stance phase in GA1 The maximum ankle plantar/dorsi flexion angles and the maximum knee extension angles were different from the normal values in the sound side. Asymmetries of the joint angles were analyzed by using the peak values. Significant asymmetries were found in GA1with seven parameters (ankle: peak planter flexion angle in stance phase, range of motion; ROM, knee: peak flexion angles during both stance and swing phase, ROM, hip: peak extension angle, ROM) while only two parameters (maximum hip extension angle and ROM of hip joint) had significant differences in GA5. The mid-stance valleys were not observed in both right and left sides of vertical ground reaction force (GRF) in the GA1, GA2. The loading response peak was far larger than the terminal stance peak of vertical ground reaction curve in the affected side of the GA3, GA4, GA5. The measured joint moment curves of the GA1, GA2, GA3 had large deviations and all of kinetic results had differences with the normal patterns. EMG signals described an absence of the rectus femoris muscle activity in the GA1 and GA2 (affected side). The EMG signals were detected in the GA3 and GA4 but their patterns were not normal yet, then their normal patterns were detected in the GA5. Through these following gait analysis of a child who had selective injuries on the knee extensor muscles, we could verify the actual functions of the knee extensor muscles during gait, and we also could observe his recovery and asymmetry with quantitative data during his rehabilitation.

Review of the Reasons in Cases Requiring Varus/Valgus Constrained Prosthesis in Primary Total Knee Arthroplasty (일차 슬관절 전치환술 시내·외반 구속형 치환물이 필요했던 사례들의 원인 분석)

  • Kong, Dong Yi;Park, Sang Hoon;Choi, Choong Hyeok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.253-260
    • /
    • 2021
  • Purpose: The least constrained prosthesis is generally recommended in primary total knee arthroplasty (TKA). Nevertheless, a varus/valgus constrained (VVC) prosthesis should be implanted when a semi-constrained prosthesis is not good for adequate stability, especially in the coronal plane. In domestic situations, however, the VVC prosthesis could not always be prepared for every primary TKA case. Therefore, it is sometimes impractical to use a VVC prosthesis for unsual unstable situations. This study provides information for preparing VVC prostheses in the preoperative planning of primary TKA through an analysis of primary VVC TKA cases. Materials and Methods: This study reviewed 1,797 primary TKAs, performed between May 2003 and February 2016. The reasons for requiring VVC prosthesis and the preoperative conditions in 29 TKAs that underwent primary TKA with a VVC prosthesis were analyzed retrospectively. Results: In primary TKA, 29 cases (1.6%) in 27 patients (6 male and 21 female) used VVC prosthesis. Two patients underwent a VVC prosthesis on both knees. The mean age of the patients was 63.4 years old (34-79 years). The mean flexion contracture was 16.2° (-20°-90°), and the mean angle of great flexion was 111.7° (35°-145°). The situations requiring a VVC prosthesis were severe valgus deformity in 10 knees, knee stiffness requiring extensive soft tissue release in 10 knees, previously injured collateral ligaments in five knees, and distal femoral bone defect due to avascular necrosis in four knees. The mean tibiofemoral angle was 25.7° (21°-43°) in 10 cases with a valgus deformity. The mean flexion contracture was 37.5° (20°-90°), and the mean range of motion was 48.5° (10°-70°) in 10 cases with knee stiffness. Conclusion: The preparation of VVC prosthesis is recommended, even for primary TKA in cases of severe valgus deformity (tibiofemoral angle>20°), stiff knee (the range of motion: less than 70° with more than 20° flexion contracture), and the cases with a previous collateral ligament injury. This information will help in the preparation of adequate TKA prostheses for unusual unstable situations.

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

A Study on the Present Condition and Improvement of Cultural Heritage Management in Seoul - Based on the Results of Regular Surveys (2016~2018) - (서울특별시 지정문화재 관리 현황 진단 및 개선방안 연구 - 정기조사(2016~2018) 결과를 중심으로 -)

  • Cho, Hong-seok;Suh, Hyun-jung;Kim, Ye-rin;Kim, Dong-cheon
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.2
    • /
    • pp.80-105
    • /
    • 2019
  • With the increasing complexity and irregularity of disaster types, the need for cultural asset preservation and management from a proactive perspective has increased as a number of cultural properties have been destroyed and damaged by various natural and humanistic factors. In consideration of these circumstances, the Cultural Heritage Administration enacted an Act in December 2005 to enforce the regular commission of surveys for the systematic preservation and management of cultural assets, and through a recent revision of this Act, the investigation cycle has been reduced from five to three years, and the object of regular inspections has been expanded to cover registered cultural properties. According to the ordinance, a periodic survey of city- or province-designated heritage is to be carried out mainly by metropolitan and provincial governments. The Seoul Metropolitan Government prepared a legal basis for commissioning regular surveys under the Seoul Special City Cultural Properties Protection Ordinance 2008 and, in recognition of the importance of preventive management due to the large number of cultural assets located in the city center and the high demand for visits, conducted regular surveys of the entire city-designated cultural assets from 2016 to 2018. Upon the first survey being completed, it was considered necessary to review the policy effectiveness of the system and to conduct a comprehensive review of the results of the regular surveys that had been carried out to enhance the management of cultural assets. Therefore, the present study examined the comprehensive management status of the cultural assets designated by the Seoul Metropolitan Government for three years (2016-2018), assessing the performance and identifying limitations. Additionally, ways to improve it were sought, and a DB establishment plan for the establishment of an integrated management system under the auspices of the Seoul Metropolitan Government was proposed. Specifically, survey forms were administered under the Guidelines for the Operation of Periodic Surveys of National Designated Cultural Assets; however, the types of survey forms were reclassified and further subdivided in consideration of the characteristics of the designated cultural assets, and manuals were developed for consistent and specific information technologies in respect of the scope and manner of the survey. Based on this analysis, it was confirmed that 401 cases (77.0%) out of 521 cases were generally well preserved; however, 102 cases (19.6%) were found to require special measures such as attention, precision diagnosis, and repair. Meanwhile, there were 18 cases (3.4%) of unsurveyed cultural assets. These were inaccessible to the investigation at this time due to reasons such as unknown location or closure to the public. Regarding the specific types of cultural assets, among a total of 171 cultural real estate properties, 63 cases (36.8%) of structural damage were caused by the failure and elimination of members, and 73 cases (42.7%) of surface area damage were the result of biological damage. Almost all plants and geological earth and scenic spots were well preserved. In the case of movable cultural assets, 25 cases (7.1%) among 350 cases were found to have changed location, and structural damage and surface area damage was found according to specific material properties, excluding ceramics. In particular, papers, textiles, and leather goods, with material properties that are vulnerable to damage, were found to have greater damage than those of other materials because they were owned and managed by individuals and temples. Thus, it has been confirmed that more proactive management is needed. Accordingly, an action plan for the comprehensive preservation and management status check shall be developed according to management status and urgency, and the project promotion plan and the focus management target should be selected and managed first. In particular, concerning movable cultural assets, there have been some cases in which new locations have gone unreported after changes in ownership (management); therefore, a new system is required to strengthen the obligation to report changes in ownership (management) or location. Based on the current status diagnosis and improvement measures, it is expected that the foundation of a proactive and efficient cultural asset management system can be realized through the establishment of an effective mid- to long-term database of the integrated management system pursued by the Seoul Metropolitan Government.

A study on the production techniques and prototype of the mother-of-pearl chrysanthemum pattern box from the Goryeo Dynasty (고려 나전국화넝쿨무늬상자의 제작기법 고찰 및 원형 연구)

  • LEE Heeseung;LEE Minhye;KIM Sunghun;LEE Hyeonju
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.126-144
    • /
    • 2024
  • The chrysanthemum vine pattern box from the Goryeo Dynasty expresses in great detail the representative features of Goryeo Dynasty lacquerware with mother-of-pearl, such as engraving patterns on the surface of fine mother-of-pearl, expressing vine stems using metal wires, and twisting metal wires to form the boundaries of each patterns. While the lacquerware with mother-of-pearl that remains today from the Goryeo Dynasty has the form of a sutra box and a box with lid, the chrysanthemum vine pattern box that is the subject of this study is in the shape of a box with a separate lid and body, making it difficult to estimate the purpose of production or the stored contents. In this study, we attempted to confirm the formative characteristics of the chrysanthemum vine pattern box in order to confirm its original form, and to investigate its structure and production technique through X-ray transmission. In addition, we attempted to identify the use and production purpose of the box by classifying and comparing the previously known lacquerware with mother-ofpearl from the Goryeo Dynasty by type. As a result of the investigation, fabric was confirmed the bottom of body and inner box through X-ray images. Through this, it was confirmed that the 'Mogsimjeopichilgi'(wooden core grabbing fabric technique) of wrapping the object with fabric was used. And through wood grain, it was possible to confirm the wooden board composition of the part presumed to be the restored part and the part presumed to have had existing Jangseog. In addition, it was confirmed that the joints were connected in a Majdaeim(part to part). Based on the survey results, a total of 14 pieces, including 9 Sutra boxes, 3 boxes, and 2 small boxes, that remain from the Goryeo Dynasty were classified by type and examined for similarity. Among them, there is a "Chrysanthemum Vine Pattern Sutra Box" from a private collection in Japan, a "Black Lacquered Chrysanthemum Arabesque Bun Sutra Box" from the Tokugawa Art Museum, a "Sutra Holder" from the British Museum, and a "Small Box with a Mother-of-Pearl Chrysanthemum Vine Pattern" from a private collection in Korea. The pattern composition of five points was most similar to the subject of this study. As a result of comparing the damage pattern, formative characteristics, and structural features of each part, it is presumed that the sutra holder in the British Museum was transformed into its current form from the original the chrysanthemum vine patterned box. Lastly, in order to confirm the purpose of production, that is, the use of this box, we investigated examples of Tripitaka Koreana printed version produced at a time similar to the social atmosphere of Goryeo at the time. Following the Mongol(元) invasion after the Goryeo military regime at the time, sutras appeared to pray for the stability of the nation and the soul of an individual, and with the development of domestic printing and paper in the 13th century, it gradually coincided with the transition from a scroll to a folded form, and the form of a box changed from a box. It is believed that the storage method also changed.