• Title/Summary/Keyword: 손상상태평가

Search Result 436, Processing Time 0.05 seconds

Aging Deterioration for Electric Power Transmission Tower on Offshore Through Periodic Inspections (해상송전철탑 구조물의 주기점검을 통한 경년열화 변화특성)

  • Lee, Ho Beom;Jang, Il Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.25-33
    • /
    • 2012
  • In electric power transmission tower structures on offshore, implementation of life management using the event data of regular safety inspections for structural and material damages is strongly recommended. In this study, six tower structures in Sihwa Lake around Yeoungheung island were target bodies for the safety inspections. safety inspections for deterioration about each of six towers were performed about three items for steel member, five items for concrete foundation, and four items for steel-pipe pile in seawater and seawater itself. Safety inspections for steel members included the visual observations of surface appearances, the measurements of member thicknesses, and the checks of painting states. Also safety inspections for concrete foundations comprised the estimation of crack features, the evaluation of non-destructive compression strengths, and the measurements of neutralization depths and chlorides contents. For steel-pipe piles in seawater the inspections comprised the surveys of corrosion states in accordance with potential levels tests and anode tests, the analyses of photos taken on surfaces of the piles as well as the evaluation of seawater quality. A set of deterioration inspections was performed at the same positions around october of each year for three consecutive years. As a result in this study, Newly developed deterioration indexes have been applied profitably to maintain structural safety for electric power transmission towers by utilizing these event data systematically.

Concrete Crack Detection Inside Finishing Materials Using Lock-in Thermography (위상 잠금 열화상 기법을 이용한 콘크리트 마감재 내부 균열 검출)

  • Myung-Hun Lee;Ukyong Woo;Hajin Choi;Jong-Chan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.30-38
    • /
    • 2023
  • As the number of old buildings subject to safety inspection increases, the burden on designated institutions and management entities that are responsible for safety management is increasing. Accordingly, when selecting buildings subject to safety inspection, appropriate safety inspection standards and appropriate technology are essential. The current safety inspection standards for old buildings give low scores when it is difficult to confirm damage such as cracks in structural members due to finishing materials. This causes the evaluation results to be underestimated regardless of the actual safety status of the structure, resulting in an increase in the number of aging buildings subject to safety inspection. Accordingly, this study proposed a thermal imaging technique, a non-destructive and non-contact inspection, to detect cracks inside finishing materials. A concrete specimen was produced to observe cracks inside the finishing material using a thermal imaging camera, and thermal image data was measured by exciting a heat source on the concrete surface and cracked area. As a result of the measurement, it was confirmed that it was possible to observe cracks inside the finishing material with a width of 0.3mm, 0.5mm, and 0.7mm, but it was difficult to determine the cracks due to uneven temperature distribution due to surface peeling and peeling of the wallpaper. Accordingly, as a result of performing data analysis by deriving the amplitude and phase difference of the thermal image data, clear crack measurement was possible for 0.5mm and 0.7mm cracks. Based on this study, we hope to increase the efficiency of field application and analysis through the development of technology using big data-based deep learning in the diagnosis of internal crack damage in finishing materials.

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

The Experimental Study for Myocardial Preservation Effect of Ischemic Preconditioning (허혈성 전조건화 유발이 심근보호에 미치는 영향에 관한 실험적 연구)

  • 이종국;박일환;이상헌
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • Decrease in cardiac function after open heart surgery is due to an ischemia induced myocardial damage during surgery, and ischemic preconditioning, a condition in which the myocardial damage does not accumulate after repeated episodes of ischemia but protects itself from damage after prolonged ischemia due to myocytes tolerating the ischemia, is known to diminish myocardial damage, which also helps the recovery of myocardium after reperfusion, and decreases incidences of arrythmia. Our study is performed to display the ischemic preconditioning and show the myocardial protective effect by applying cardioplegic solution to the heart removed from rat. Material and Method: Sprague-Dawley male rats were used, They were fixed on a modified isolated working heart model after cannulation. The reperfusion process was according to non-working and working heart methods and the working method was executed for 20 minutes in which the heart rate, aortic pressure, aortic flow and coronary flow were measured and recorded. The control group is the group which the extracted heart was fixed on the isolated working heart model, recovered by reperfusion 60 minutes after infusion and preserved in the cardioplegic solution 20 minutes after the working heart perfusion and aortic cross clamp, The thesis groups were divided into group I, which ischemic hearts that were hypoxia induced were perfused by cardioplegic solution and preserved for 60 minutes; group II, the cardioplegic solution was infused 45 seconds (II-1), 1 minutes (II-2), 3 minutes (II-3), after the ischemia induction, 20 minutes after working heart perfusion and aortic cross clamp; and group III, hearts were executed on working heart perfusion for 20 minutes and aortic cross clamp was performed for 45 seconds (III-1), 1minute (III-2), 3 minutes (III-3), reperfused for 2 minutes to recover the heart, and then aortic cross clamping was repeated for reperfusion, all the groups were compared based on hemodynamic performance after reperfusion of the heart after preservation for 60 minutes. Result: The recovery time until spontaneous heart beat was longer in groups I, II-3, III-2 and III-3 to control group (p<0.01). Group III-1 (p<0.05) had better results in terms of recovery in number of heart rates compared to control group, and recovered better compared to II-1 (p<0.05). The recovery of aortic blood pressure favored group III-1 (p<0.05) and had better outcomes compared with II-1 (p<0.01). Group III-1 also showed best results in terms of cardiac output (p<0.05) and group III-2 was better compared to II-2 (p<0.05). Group I (p<0.01) and II-3 (p<0.05) showed more cardiac edema than control group. Conclusion: When the effects of other organs are dismissed, protecting the heart by infusion of cardioplegic solution after enforcing ischemia for a short period of time before the onset of abnormal heart beats for preconditioning has a better recovery effect in the cardioplegic group with preconditioning compared to the cardioplegic solution itself. we believe that further study is needed to find a more effective method of preconditioning.

Effect of Humidified High Flow CO2 Gas Insufflation on the Coronary Endothelium (가습화한 고유량의 이산화탄소가스 통기가 관상동맥 내피세포층에 미치는 영향)

  • 최재성;김준성;서정욱;김기봉
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.131-138
    • /
    • 2004
  • High-flow gas insufflation to get a bloodless field during off-pump coronary artery bypass may have adverse effects on the coronary endothelium. This study was designed (1) to elucidate the effect of carbon dioxide gas insufflations on the coronary endothelium at different flow rates and (2) to assess the protective effect of humidifcation against the coronary endothelial damage. Material and Method: In nine pigs, the left anterior descending coronary artery (LAD) was exposed after a median sternotomy. The LAD was divided into 4 segments and a coronary arteriotomy was made in each LAD segment in the beating heart. The far distal arteriotomy was exposed to room air for 10 minutes and was harvested as a control. Non-humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group I), humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group II), and humidified carbon dioxide gas at a continuous flow rate of 10 L/min (Group III) were insufflated for 10 minutes on each coronary arteriotomy site, respectively. After harvesting the coronary segments, hematoxylin-eosin staining, elastic fiber staining, and immunostaining with a CD34 monoclonal antibody were performed to evaluate the depth of endothelial damage and to count the residual endothelial cells, Result: In all three groups (Group I, II, and III), internal elastic laminae were preserved, however, the endothelial layers were significantly damaged by carbon dioxide gas insufflation. The mean percentages of remaining endothelial cells were 20,9$\pm$16.7%, 39.3$\pm$19.6%, and 6.8$\pm$5.3%, in groups I, II, and III, respectively. The percentages of remaining cells were significantly higher in group II than in groups I and III (p=0.008). The percentages of remaining cells were significantly higher in group I than in group III (p=0.008). Conclusions: The harmful effect of carbon dioxide gas insufflation on the coronary endothelium was dependent on the flow rate. The addition of humidification did not protect the coronary endothelium from denudation injury caused by high flow carbon dioxide gas insufflations.

Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS) (EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링)

  • Woo, Seong-Yeop;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.651-662
    • /
    • 2022
  • The electrochemical impedance spectroscopy(EIS) method was used to evaluate the concrete deterioration process related to chloride-induced steel corrosion with various corrosion levels(initiation, rust propagation and acceleration periods). The impressed current technique, with four total current levels of 0C, 13C, 65C and 130C, was used to accelerate steel corrosion in concrete cylinder samples with w/c ratio of 0.4, 0.5, and 0.6, immersed in a 0.5M NaCl solution. A series of EIS measurements was performed to monitor concrete deterioration during the accelerated corrosion test in this study. Some critical parameters of the equivalent circuit were obtained through the EIS analysis. It was observed that the charge transfer resistance(Rc) dropped sharply as the impressed current increased from 0C to 13C, indicating a value of approximately 10kΩcm2. However, the sensitivity of Rc significantly decreased when the impressed current was further increased from 13C to 130C after corrosion of steel had been initiated. Meanwhile, the double-layer capacitance value(Cdl) linearly increased from 50×10-6μF/cm2 to 250×10-6μF/cm2 as the impressed current in creased from 0C to 130C. The results in this study showed that monitoring Cdl is an effective measurement parameter for evaluating the progress of internal concrete damages(de-bonding between steel and concrete, micro-cracks, and surface-breaking cracks) induced by steel corrosion. The findings of this study provide a fundamental basis for developing an embedded sensor and signal interpretation method for monitoring concrete deterioration due to steel corrosion at various corrosion levels.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

The Definition of Frail Elderly and the Frailty Screening Assessment Tool: A Systematic Review (허약노인의 정의 및 허약 선별 평가도구에 관한 체계적 고찰)

  • Lee, Gyeong A;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.3
    • /
    • pp.43-56
    • /
    • 2021
  • Objective : The objective of this study was to present the components of frailty by organizing the definitions of frail elderly and analyzing the tools used to screen them. Methods : This study searched for articles at involved frailty screening assessments in the elderly. Databases including CINAHL, Embase, Medline Complete, and PubMed were searched. The search terms were "assess" AND "frailty" AND "screening" AND ("frail elderly" OR "elderly"). Results : A total of 539 articles were identified by the search and 11 articles were selected. Frailty occurs due to the depressed function of multidimensional factors, and a frail elderly person is defined as one at high risk of health degeneration, functional impairment, and occurrence of disability, and having a high level of threat to life. Seven tools were selected from 11 articles. The most frequently used tool was the frailty phenotype, which was used in five articles (45.4%). The identified components of frailty were physical, activity participation, nutrition, psychological, social, overall health, and age. Conclusion : The results confirmed the definition and components of frailty. This study is expected to contribute to the future development of standardized evaluation tools for screening frail elderly individuals and intervention programs for the management of the frail elderly.

Development on Antibiotic Concrete Mixed with Antibacterial Metals and Metallic Salts (금속 및 금속염계 항균제가 혼입된 항균 콘크리트 개발)

  • Choi, Hong-Shik;Heo, Kwon;Lee, Ho-Beom;Lee, Si-Woo;Kwak, Hong-Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the sewage structures and wastewater facilities, concrete is exposed to hydrogen sulfide ($H_2S$) which acts as an acid material in a solution, and a strongly acidic sulfate ion ($SO{_4}^{-2}$) is generated by a sulfuric bacteria. Hence, a degradation of concrete with biochemical corrosion would be accelerated. Finally, durability of concrete and concrete structures may be greatly reduced. In this study, in order to remove the hydrogen sulfide which is used by the sulfuric bacteria organic-biologically, the antibiotic metal and metallic salt powders were mixed to concrete, and a suppressing performance of the sulfate ion was assessed. For the sulfuric acid bacteria, a comparative evaluation of antimicrobial performance on neutralized concrete specimens were carried out, also by a rapid chloride penetration test, chloride penetration depths and diffusion coefficients were measured for antibiotic concrete in accordance with the amount of metal and metallic salt-based antibacterial agents. Eventually, by an observation of the biochemical state of the surface of concrete specimens exposed outdoors, the performance and applicability of antibiotic concrete were confirmed.

Effect of Incubation Time after Cooling on the Meiotic Spindle and Chromosomes of Mouse Oocytes (냉각 후 배양시간이 생쥐 난자의 방추체와 염색체에 미치는 영향)

  • Yu I.
    • Journal of Embryo Transfer
    • /
    • v.19 no.3
    • /
    • pp.283-289
    • /
    • 2004
  • This study was conducted to determine the effects of incubation time after cooling on mouse meiotic spindle and chromosome alignment and the optimal incubation time for their restoration. Oocytes at the metaphase II were obtained from superovulated mice. Control oocytes were held at 37$^{\circ}C$ during the experiment. Oocytes were rapidly cooled to $0^{\circ}C$, held for 30 minutes, warmed and incubated at 37$^{\circ}C$ for 5, 15, 30, 60 and 120 minutes, respectively. The morphological features of spindle and chromosomes in oocytes were evaluated by immunofluorescent staining. Meiotic spindle of control oocytes exhibited a normal-looking bipolar configuration(barrel-shaped) and highly fluorescent microtubles. The chromosomes were clustered in a discrete bundles at metaphase plate. Disassembly of meiotic spindle and chromosome dispersion were occurred immediately after chilling of oocyte. Fluorescence intensity index(FIS), normal chromosomes aligned and normal spindle configuration were compared according to incubation time at 37$^{\circ}C$. Restoration of a barrel-shaped spindle and normal chromosome alignment was occurring after 5 minutes incubation at 37$^{\circ}C$, improved as a incubation time increased, and decreased gradually after 120 minutes incubation(P<0.05). The optimal incubation time for restoration of meiotic spindle and chromosomes in cooled oocytes was 60 minutes.