Identification of damage states and damge indices of single box tunnel from inelastic seismic analysis (비탄성 지진 해석을 통한 박스 터널의 손상 상태 및 손상 지수 규명)

  • Park, Duhee;Lee, Tae-Hyung;Kim, Hansup;Park, Jeong-Seon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.119-128
    • /
    • 2016
  • In a performance-based design, the structural safety is estimated from pre-defined damage states and corresponding damage indices. Both damage states and damage indices are well defined for above-ground structures, but very limited studies have been performed on underground structures. In this study, we define the damage states and damage indices of a cut-and-cover box tunnel which is one of typical structures used in metro systems, under a seismic excitation from a series of inelastic frame analyses. Three damage states are defined in terms of the number of plastic hinges that develop within the structure. The damage index is defined as the ratio of the elastic moment to the yield moment. Through use of the proposed index, the inelastic behavior and failure mechanism of box tunnels can be simulated and predicted through elastic analysis. In addition, the damage indices are linked to free-field shear strains. Because the free-field shear strain can be easily calculated from a 1D site response analysis, the proposed method can be readily used in practice. Further studies are needed to determine the range of shear strains and associated uncertainties for various types of tunnels and site profiles. However, the inter-linked platform of damage state - damage index - shear wave velocity - shear strain provides a novel approach for estimating the inelastic response of tunnels, and can be widely used in practice for seismic designs.

Improved Damage Assessment Algorithm Using Limited Mode Shapes (제한된 모드형상을 이용한 개선된 손상평가 알고리즘)

  • 이종순;조효남;허정원;이성칠
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.127-136
    • /
    • 2002
  • This papers presents a practical damage detection algorithm based on damage index method that accurately assesses both the location and severity of the localized detriment in a bridge structure using only limited mode shapes. In the algorithm, the ratio of the modal vector sensitivity of an undamaged structure to that of a damaged structure is used as an indicator of damage. However, a difficulty arises when the damaged element is located at a node of mode where the amplitude of medal vector is close to zero, leading the singularity of the ratio (i.e., division-by-zero). This singularity problem is overcome by introducing a parameter denoted a sensitivity filter, a function of mode shape of the structure, in modal vector sensitivity. Using this concept, an improvement can be considerably achieved in the estimation of both degree of severity and location of damage. To verify the proposed algorithm, its numerical implementations are conducted for a simply supported beam and a 2-span continuous beam.

Making Method of Deterioration Map and Evaluation Techniques of Surface and Three-dimensional Deterioration Rate for Stone Cultural Heritage (석조문화유산의 손상지도 제작방법과 표면 및 3차원 손상율 평가기법)

  • Jo, Young-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.251-260
    • /
    • 2011
  • This study focus on the suggestion of standard legend, the process system on making method of deterioration map, the development of crack index (CI), and the evaluation techniques of surface and 3D deterioration rate for stone cultural heritage. The standard legends of deterioration forms were made using a common graphic program after crack, blistering, scaling, break-out, granular disintegration, and perforation were subdivided. The deterioration map improved accuracy and reliability on deterioration range using 3D digital restoration and high resolution photograph mapping technique. Also, quantitative deterioration evaluation of stone cultural heritage was carried out developing the crack index, and the 3D deterioration rate of a break-out part was calculated by virtual restoration modeling. As a quantitative deterioration evaluation of Magoksa Temple stone pagoda based on the results described above, the north face showed high deterioration rate of bursting crack (1.70), hair crack (1.34), scaling (20.2%) and break out (13.0%), and the 3D deterioration rate of first roof stone was 6.7%.

Damage Identification in Truss Bridges using Damage Index Method (손상지수법을 이용한 트러스 교량의 손상추정)

  • Lee, Bong Hak;Kim, Jeong Tae;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.279-290
    • /
    • 1998
  • An existing Damage Index Method is verified to demonstrate its feasibility for detecting structural damage in truss bridges (1) for which modal parameters are available for a few modes of vibration and (2) for which baseline modal information is not available from its as-built state. The theory of approach to detect locations of damage and to identify baseline modal model is summarized on the basis of system identification theory and modal sensitivity theory. The feasibility of the Damage Index Method is demonstrated using a numerical example of a truss bridge with 11 subsystems of 211 members and for which only two modes of vibration were recorded for post-damaged state.

  • PDF

A Study on the Damage of Steel Square Tubular Columns under Cyclic Loading (반복재하를 받는 각형강관기둥의 손상에 관한 연구)

  • Park, Yeon Soo;Jeon, Dong Ho;Suh, Byoung Chal;Kim, Wook;Choi, Dong Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.369-378
    • /
    • 2003
  • This study proposed a damage index for steel members and examined a process where steel square tubular columns under cycle loading failed to meet the damage index. A nonlinear analysis was carried out and a damage process analyzed using a finite element program. Material properties and strain characteristics were obtained from material testing. The effect on the damage of members was analyzed according to varying kinds of steels and conditions of loading based on material testing results. According to strain characteristics and cumulative plastic strain of each variable, the effect of conditions of loading and kinds of steels on the damage could be estimated quantitatively.

Damage Detection in a Beam Structure Using Modal Strain Energy (빔 구조물의 모달 변형에너지를 이용한 손상탐지)

  • 박수용;최상현
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.333-342
    • /
    • 2003
  • The objective of this paper is to present an algorithm to locate and size damage in a beam structure. The method uses the changes in the modal strain energy distribution. A damage index, utilized to identify possible location and corresponding severity of local damage, is formulated and expressed in terms of modal displacements that can be obtained from mode shapes of the undamaged and the damaged structures. The possible damage locations in the structure arc determined by the application of damage indicator according to previously developed decision rules. The robustness and effectiveness of the method arc demonstrated using numerical examples of beam structures with simulated damage.

Modeling of Damage Initiation in Singly Oriented Ply Fiber-Metal Laminate under Concentrated Loading Conditions (집중하중을 받는 일방향 보강 섬유 금속 적층판의 손상 개시 모델링)

  • 남현욱;변현중;정성욱;한경섭
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.42-50
    • /
    • 2001
  • Modeling of damage initiation in singly oriented ply (SOP) Fiber Metal Laminate (FML) under concentrated loading conditions was studied. The finite element method (FEM) base on the first order shear deformation theory is used for th\ulcorner modeling of damage initiation in SOP FML. The failure indices (FI) of the fiber prepreg and the metal laminate were calculated by using the Tasi-Hill failure criterion and the Miser yield criterion, respectively. To verify the present method, the failure analysis was conducted under uniaxial loading and cylindrical bending, then the analysis under concentrated load was conducted. The results show that the analysis is reasonable. An indentation test was conducted to compare a damage initiation load with a calculated FI. The test was conducted under two side clamped conditions to study the fiber orientation effect. Indentation curve was fitted using the Hertz equation and a damage initiation load is defined that the point which deviate the fitted curve from the real indentation curve. The damage initiation loads were obtained under various fiber orientations and compared with calculated FIs. The experiment was well matched with calculated FI. This results shows that the present method is suitable for the damage initiation modeling of SOP FML.

  • PDF

Local Damage Detection Using Acceleration ARX Model (가속도 ARX 모델을 사용한 국부손상 탐색)

  • Shin, Soobong;Park, Hye-Youn;Kim, Jae-Cheon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.115-121
    • /
    • 2009
  • The paper presents a signal-based damage detection algorithm of ARX model using dynamic acceleration data. An ARX model correlates acceleration data measured at two locations in a structure by considering those two sets of data as input and output signals. For detecting damage, the error between the measured data and the predicted response from the defined ARX model is computed in time and used for a statistical evaluation. A normal distribution function from the error in time is constructed and its statistical characteristic values are used for the evaluation of damage. By comparing the normal distribution functions before and after damage, three different types of damage indices are proposed. The efficiency and limitation of the proposed algorithm with the statistical evaluation of damage indices have been examined and discussed through laboratory experiments.

Damage Index Evaluation Based on Dissipated Energy of SCH 40 3-Inch Carbon Steel Pipe Elbows Under Cyclic Loading (주기적 하중을 받는 SCH 40 3-Inch 탄소강관엘보의 소산에너지 기반의 손상지수 평가)

  • Kim, Sung-Wan;Yun, Da-Woon;Jeon, Bub-Gyu;Kim, Seong-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.112-119
    • /
    • 2021
  • The failure mode of piping systems due to seismic loads is the low-cycle fatigue failure with ratcheting, and it was found that the element in which nonlinear behavior is concentrated and damage occurs is the elbow. In this study, to quantitatively express the failure criteria for a pipe elbow of SCH40 3-inch carbon steel under low-cycle fatigue, the limit state was defined as leakage, and the in-plane cyclic loading test was conducted. For the carbon steel pipe elbow, which is the vulnerable part to seismic load of piping systems, the damage index was represented using the moment-deformation angle relationship, and it was compared and analyzed with the damage index calculated using the force-displacement relationship. An attempt was made to quantitatively express the limit state of the carbon steel pipe elbow involving leakage using the damage index, which was based on the dissipated energy caused by repeated external forces.

Damage Monitoring for Wind Turbine Blade using Impedance Technique (임피던스 기법을 이용한 풍력 블레이드 손상 모니터링)

  • Huh, Yong-Hak;Kim, Jongil;Hong, Seonggu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.452-458
    • /
    • 2013
  • Impedance based monitoring technique was investigated to evaluate the damage occurring in wind turbine blade. In this study, PVDF film piezo sensors were patched on the 10 kW wind turbine blade, and impedance was measured over the frequency range of 1~200 MHz under fatigue loading. With applying fatigue loads on the blade, change in maximum deflection of the blade and local strain values could be obtained from the strain gages attached on the blade, and difference of the impedance signatures was also observed. From these data, it could be found that local damage or geometrical change in the blade structure happened. To quantitatively compare the impedance signature patterns, a statistical algorithm, scalar damage metric M was used. It was calculated from the impedance signatures considering fatigue loads and location of the sensors. The metric values were compared to correlate the metrics with damage in the blade.