• Title/Summary/Keyword: 손목형 심박수 측정기

Search Result 6, Processing Time 0.018 seconds

Study on the Validity of Recently Introduced Wrist Watch Type Heart Rate Monitoring Device (최근 소개된 손목형 심박수 측정 장치의 유용성에 관한 연구)

  • Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • There are several ways to analyse stress resulting from anxiety and fear within dental treatment for children. Surveying questionnaires and monitoring biologic reaction are the most common ways for evaluating stress. Pulse oximeter is a popular device for detecting heart rate but not appropriate for moving children. In this study, we compared a recently introduced wrist- watch type heart rate monitor(Alpha, MIO, USA) with a pulse oximeter(MP110, MECKIS, Republic of Korea) for 10 attendants with two conditions including resting state and excited state after exercise. Data were analyzed using Wilcoxon Signed Rank test and there is no statistical difference between two devices(p < 0.05).

The Assessment of Stress of Children under Dental Procedures Using Wrist Watch Type Heart Rate Monitoring Devices - Using New Device for Stress Assessment in Children During Restorative Dental Treatment (손목형 심박수 측정 장치를 이용한 어린이의 치과진료 시 스트레스 평가)

  • Oh, Jungeun;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.2
    • /
    • pp.119-125
    • /
    • 2015
  • Dental stress is suggested as a main reason for behavioral problems in dentistry, especially in children. Heart rate is a useful measure of dental stress. The purpose of the present study is to examine the effect of dental stress on children receiving restorative treatment under local anesthesia by using recently introduced a wrist-watch type heart rate monitoring device. Eighteen children with no previous dental experience, who needed dental treatment involving local anesthesia, were included in this study. In each session, heart rate was recorded. The largest increase was observed during local anesthesia and the highest values were recorded during preparation. However, no significant relationship was found between the measurements(p > 0.05). Regarding the number of visits, heart rate on the second session is significantly higher than the first session and the third session(p < 0.05). There was no significant different correlation between the first session and third session(p > 0.05). Based on the present study, children who have no previous dental treatment appeared to be more stressed at the second session and need at least 3 sessions to feel less stressed during dental treatment including dental injection.

Design of A Portable Device for Measuring Heart Rate Using Harmonic Signal and Adaptive Filter (하모닉 신호와 적응 필터를 이용한 휴대형 심박수 측정 장치 설계)

  • Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.723-728
    • /
    • 2010
  • This study proposed a design of a portable device for measuring heart rate using photoplethysmograph signal to minimize load of a nurse increased from insufficiency of an internal hospital nurse, and algorithm to measure reliable heart rate in PPG signals despite the existence of patient's motion artifacts. The proposed method for measuring heart rate is the method to minimize the motion interference by using the adaptive filter based on harmonic characteristic of PPG signal. To evaluate the performances of the a portable device implemented by the proposed method, we used several motion artifacts including finger and wrist movements; we then compared out results with the performance of the moving average filter. In this results, the proposed method showed a better performance than that of the moving average filter. Therefore, when nurses use the a portable device for measuring heart rate proposed in this study, it will enable to improve nurse work and to measure the reliable heart rate.

Arduino-based Heart Rate Device for Smart Healthcare (스마트 헬스케어를 위한 아두이노 기반의 심박 측정기 제작)

  • Shin, Chae-lynn;Cho, Young-bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.104-105
    • /
    • 2021
  • Along with the rapid development of ICT, health management is continuing based on various smart healthcare devices in an aging society and non-face-to-face era caused by COVID-19. In this paper, a heart rate monitor was manufactured using the DF Robot SEN0203 heart rate sensor based on Arduino so that you can check your health and maintain a healthy life by measuring the heart rate per minute in real time to support personalized health management. The device manufactured through this thesis can be used in various ways, such as a wristband or a smart watch.

  • PDF

The Changes of the Heart Rate, Hand Function, and Health related Quality of Life of the People with Intellectual Disability through the Increase of the Auditory Stimulation (청각자극 증가에 따른 지적장애인의 심박수와 손 기능, 건강관련 삶의 질의 변화)

  • Son, Sung-Min;Kang, Jin-Ho;Bak, Ah-Ream
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.5
    • /
    • pp.217-227
    • /
    • 2020
  • The purpose of the study is to analyze the changes of the heart rate, hand function, and health related quality of life of the people with intellectual disability through the increase of the auditory stimulation. The subjects were 16 people with intellectual disability. The increase of the auditory stimulation was modulated through the music sound and the intensity was consisted of 60dB, 65dB and 70dB. The wist heart rate and blood pressure monitor was used to measure the heart rate during the application of the auditory stimulation increase. The hand function of right and left hand was measured by the Purdue pegboard. Health related of quality of life was measured by the short form-8 health survey. As the results, the increase of the heart rate was showed by the increase of the auditory stimulation and the decrease of the hand function and health related quality of life was showed. For these, the increase of the auditory stimulation acts as a psychological distress, thereby the increase of the heart rate and the reduction of the hand function and health relate quality of life showed. Thus, to decrease of the heart rate and increase the hand function and the health related quality of life of the people with intellectual disability, the intensity of the auditory stimulation should be considered in the environmental stimulation.

Changes in the Health Life of the Elderly Through the Handle Height of Walking Assistant Vehicle Article : Emphasizing on State Anxiety, Heart Rate and Fall Efficacy (보행보조차 손잡이 높이에 따른 노인들의 건강생활의 변화 : 상태불안과 심박수, 낙상효능감을 중심으로)

  • Son, Sung-Min;Kwag, Sung-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.519-528
    • /
    • 2020
  • Purpose of this study is to analyze the changes in state anxiety, heart rate, and fall efficacy of the elderly through the handle height of walking assistant vehicle (WAV). The subjects were 32 elderlies. WAV was in the form of strollers, and it's handle height was set as 48% of a subject's total height. Also, it's height was divided into 48, 43, 38%. To measure the state anxiety, Korean State-Trait Anxiety Inventory was used and to measure the heart rate, Fitbit Charge 2 wrist heart rate monitor was used. To measure the fall efficacy, Fall Efficacy Scale-Korea was used. As the results of state anxiety and heart rate, the statistically significant increase showed continuously through the decrease of the handle height of WAV. As the results of fall efficacy, the statistically significant decrease showed continuously through the decrease of the handle height of WAV. In all of the post hoc test, the results of the state anxiety and fall efficacy showed significant difference among the each handle height of WAV and the results of the heart rate showed significant difference between the 48, 43% and 38% handle height of WAV. Thus, to decrease the state anxiety and heart rate and increase the fall efficacy of the elderly, the handle height of WAV should be properly positioned and considered to adjust to 48% of the user's total height.