• Title/Summary/Keyword: 속도제어밸브

Search Result 79, Processing Time 0.026 seconds

Pressure Ripple Reduction in High Speed On-Off Solenoid Valves Driven by PWM Control (PWM 제어 고속 온-오프 전자밸브에서 발생하는 압력맥동 저감)

  • Kim D.T.;Lee S.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.2
    • /
    • pp.8-13
    • /
    • 2005
  • This paper investigates a fast, accurate and inexpensive hydraulic motor speed control system using high speed on-off solenoid valves. In order to retain the advantages of the two position valve and obtain better performance, the valves are operated by pulse width modulation(PWM) control. PWM signal is generated from a LabWIEW program in microcomputer in order to set up various duty ratio and frequency of carrier wave in PWM signal with varying system parameters. As the results of experiments, the speed control of a hydraulic motor was successfully implemented using on-off solenoid valves. In order to attenuate the pressure ripple and speed variation due to discontinuously controlled flow through the on-off valves, a resonator hose fabricated for automobile power steering system was connected between the valve and a hydraulic motor. From experimental results obtained in the hydraulic motor system with a resonator hose, it was ascertained that the resonator hose showed excellent performances in reducing pressure ripple and motor speed variation.

  • PDF

Mechanical Properties for Methyl Cellulose(MC) Ingredient ER Fluids According to the Numbers of the Electrical Field Cycles (전기장 싸이클 수에 따른 MC성분 ER유체의 기계적성질)

  • 김옥삼;박우철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.296-301
    • /
    • 2001
  • Electro-Rheological (ER) fluids belong to a class of colloidal suspensions whose global characteristics can be controlled by the imposition of an appropriate external electrical field upon the fluid domain. The ER fluids for smart hydraulic system are a class of colloidal dispersion which exhibit large reversible changes in their rheological behavior when subjected to external electrical fields. This paper presents experimental results on mechanical properties of an ER fluids subjected to electrical fatigues. As a first step, ER fluid is made of methyl cellulose(MC) ingredient choosing 25% of particle weight-concentration. Following the construction of test for mechanical properties of ER fluid, the shear stress, dynamic yield stress and current density of the ER fluids are experimentally distilled as a function of electric field cycles. The mechanical properties test of operated ER fluids are distilled and compared with those of unused ER fluids.

  • PDF

Design of Optimal Idle Speed Controller by Sliding Mode Observer (슬라이딩 모드 관측기에 의한 최적의 공회전 제어기 설계)

  • Lee, Young-Choon;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.10
    • /
    • pp.161-167
    • /
    • 2001
  • This paper presents an approach to nonlinear engine idle controller and intake manifold absolute pressure(MAP) observer based on mean torque production model. A stable engine idle speed is important in that the unstable engine Idle mode can make engine to drooping or stall state. A sliding fuzzy controller has been designed to control engine idle speed under load disturbance. A sliding observer is also developed to estimate the intake manifold absolute pressure and compared with the actual MAP sensor value. The sliding mode observer has shown good robustness and good tracking performance. The inputs of sliding fuzzy controller are the errors of rpm and MAP. The output is a duty cycle(DC) for driving a idle speed control valve(ISCV).

  • PDF

A Study on Position Control of Hydraulic Single-Rod Cylinder Subjected to Load Disturbance (부하외란을 받는 편로드 유압실린더의 위치제어에 관한 연구)

  • 윤일로;염만오
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.89-95
    • /
    • 2003
  • A PID controller integrated with a velocity feedback is designed for fluid power elevator model system in this study. In this case, for outside disturbance load a hydraulic cylinder and a pressure control valve are used. In this method overshoot is reduced and settling time becomes also shorter than the values achieved from the PID controller system only In conclusion a PID controller integrated with a velocity feedback is considered a suitable control method for fluid power elevator system.

Numerical Study on Cavitation Reduction in Velocity-Control Trim of Valve with High Pressure Drop (고차압 밸브의 속도제어형 트림에서 케이테이션 억제에 관한 수치적 연구)

  • Kim, Dae Kwon;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.863-871
    • /
    • 2013
  • Flow characteristics of velocity-control trim in a valve is investigated numerically with high pressure drop. A basic trim widely used for a valve in domestic powerplants is selected and designed for a baseline of velocity-control trim. The numerical analysis is focused on flow rate and cavitation with the basic trim. For a condition of high-pressure drop, pressure drop between inlet and outlet and fluid temperature are selected to be 18.1 MPa and $160^{\circ}C$, respectively, which are typical ones considering operating conditions adopted in powerplants. With this baseline model and condition, design changes are made for improvement of flow rate and cavitation phenomenon. For re-design, trim is divided into three zones in radial direction and design parameters of flow area, stage, and flow direction are considered in each zone. With these combined parameters applied to each zone, 4 models with design changes are proposed and their flow rates and cavitation areas are investigated. From comparison with those in the baseline model of a basic trim, proposed models show better performance in both flow rate and cavitation.

The Effect of Cleaning the Intake System of LPG Vehicles on Engine and Emissions (LPG차량 흡기계통 Cleaning이 엔진 및 배출가스에 미치는 영향)

  • Hong, Sung-In;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1229-1235
    • /
    • 2014
  • At the LPG vehicle air intake system, most of dust particles in the air cleaner are removed. However very small particles are not removed and accumulated. The accumulation of carbon in air intake system is going to affect the idle speed control and sensor signal. It also causes engine chattering and transmission troubles of automatic transmission. This is study about cleaning up intake system using cleaning chemical. We can clean up the intake system by spraying cleaning liquid onto intake device when the engine is idling after intake hose is removed from warmed up vehicle. We can obtain the following experimental results by cleaning up ISC, surge tank, intake manifold, intake valves and combustion chamber. According to this results, the stroll valve works correctly and power rate of engine is up to the standard, it is smoothy to control the idling speed when a vehicle pulls up. After cleaning up CO grow down about 0.15%, HC does about 20~100 ppm.

Study of Thrust Control Performance Improvement for Hybrid Rocket Applications (하이브리드 로켓의 추력제어 성능 향상에 관한 연구)

  • Choi, Jae-Sung;Kang, Wan-Kyu;Huh, Hwan-Il
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.55-62
    • /
    • 2011
  • In this study, we tried to improve the thrust control performance through the thrust control combustion experiment of the hybrid rocket. We constructed the system which controls the oxidizer flow by combining a needle valve with a stepping motor and controlling the stepping motor drive according to the thrust control command order. Gas oxygen was used as the oxidizer for two different propellants, PE(Polyethylene), PC(Polycarbonate), respectively. To improve the slow response time and the oscillation phenomenon in the beginning stage of the thrust control combustion experiment, we measured and analyzed the change of the flow speed of the propellant pipe. The revised thrust control combustion experiment showed that the thrust was stably controlled with the margin or error from the thrust command within ${\pm}1$ N.

A Study on a Precision Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on Fuzzy Control (퍼지제어를 이용한 공작 기계용 오일 쿨러의 핫가스 바이패스방식 정밀 온도 제어에 관한 연구)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.3
    • /
    • pp.205-211
    • /
    • 2013
  • Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the working speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a oil cooler to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the oil cooler system. This paper deals with design and implementation method of fuzzy controller for obtaining precise temperature characteristic of HB oil cooler system in machine tools. The opening angle of an electronic expansion valve are controlled to keep reference value and room temperature of temperature at oil outlet. Especially, the fuzzy controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.22^{\circ}C$.

System Design and Performance Test of Hydraulic Intensifier (유압 충격압력 발생기의 시스템 설계와 성능평가)

  • Kim, Hyoung-Eui;Lee, Gi-Chun;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.947-952
    • /
    • 2010
  • Components such as pressure vessel, hydraulic hose assembly, accumulator, hydraulic cylinder, hydraulic valve, pipe, etc., are tested under the impulse-pressure conditions prescribed in ISO and SAE standards. The impulse pressure test machine needs to have a high pressure, a precise control system and a long life. It should satisfy the requirements for fabrication of the impulse tester to generate ultra high pressure in the hydraulic system. In the impulse tester, a servo-valve control system is adopted; although the control application is convenient, it is expensive owing to the cost of developing the system. The type of the control system determines the pressure wave, which affects the components that are tested. In this study, the manufacturing process and the intensifier system design related to the flow, pressure, and the increasing rate of pressure are investigated. The results indicate the ultra high pressure waves in the system.

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF