• Title/Summary/Keyword: 속도경계제어

Search Result 73, Processing Time 0.022 seconds

Performance analysis of session admission control based on area for software download in cellular CDMA systems (셀룰러 CDMA 시스템에서 소프트웨어 다운로드를 위한 영역 기반 세션수락제어방식 성능분석)

  • 김광식;조무호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5A
    • /
    • pp.294-304
    • /
    • 2003
  • For an efficient software download in cellular CDMA systems, session admission control based on area (SACA) is presented. In the SACA scheme, the base station only allows mobile terminal to start session when the mobile locates near the base station of a cell. A mobile that is located near cell center can request software download session, but the mobile that is far away from the center can request session only after arriving near the cell center. Session duration time follows exponential and Pareto distribution. Performance is analyzed in terms of handoff rate, mean channel holding time, session blocking probability and handoff forced termination probability. As analysis results, handoff rate between cells in the proposed scheme is reduced to 30 ~ 250 % compared to conventional scheme, according to traffic characteristics such as terminal speed, session duration time and the size of the allowable zone area in a cell for the start of the session. And new session blocking probability slightly decreases to 5 ~ 20 %, but handoff session forced termination probability drastically decreases to 35 ~ 220 %.

Design of Supersonic Wind Tunnel for Analysis of Flow over a Backward Facing Step with Slot Injection (슬롯 분사가 있는 후향계단 유동장 분석을 위한 초음속풍동 설계)

  • Kim, Ick-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.363-367
    • /
    • 2016
  • A test section of a supersonic wind tunnel was designed for the analysis of flow characteristics over a backward-facing step with Mach 1.0 slot injection in a supersonic flow of Mach 2.5. The cavity flow of a high-speed vehicle is very complex at supersonic speed, so it is necessary to do experiments using supersonic wind tunnels to verify numerical analysis methods. The previous 2D symmetrical nozzle was replaced with an asymmetrical nozzle. The inviscid nozzle contour was designed using Method of Characteristics (MOC), and the boundary layer thickness correction was reflected by experimental data from the wind tunnel. The results were compared with a CFD analysis. The PID control system was changed to be based on the change of tank pressure. This improved the control efficiency, and the run times of supersonic flow increased by about 1 second. The flow characteristics over a backward facing step with slot injection were visualized by a Schlieren device. This equipment will be used for an experimental study of the film cooling effectiveness over a cavity with various velocities, mass flows, and temperatures.

An Effective Cache Test Algorithm and BIST Architecture (효율적인 캐쉬 테스트 알고리듬 및 BIST 구조)

  • Kim, Hong-Sik;Yoon, Do-Hyun;Kang, Sing-Ho
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.12
    • /
    • pp.47-58
    • /
    • 1999
  • As the performance of processors improves, cache memories are used to overcome the difference of speed between processors and main memories. Generally cache memories are embedded and small sizes, fault coverage is a more important factor than test time in testing point of view. A new test algorithm and a new BIST architecture are developed to detect various fault models with a relatively small overhead. The new concurrent BIST architecture uses the comparator of cache management blocks as response analyzers for tag memories. A modified scan-chain is used for pre-testing of comparators which can reduce test clock cycles. In addition several boundary scan instructions are provided to control the internal test circuitries. The results show that the new algorithm can detect SAFs, AFs, TFs linked with CFs, CFins, CFids, SCFs, CFdyns and DRFs models with O(12N), where N is the memory size and the new BIST architecture has lower overhead than traditional architecture by about 11%.

  • PDF

Static Single Assignment Form for Java Bytecodes in CTOC (CTOC에서 자바 바이트코드를 위한 정적 단일 배정 형태)

  • Kim, Ki-Tae;Yoo, Weon-Hee
    • The KIPS Transactions:PartD
    • /
    • v.13D no.7 s.110
    • /
    • pp.939-946
    • /
    • 2006
  • Although the Java bytecode has numerous advantages, there are also shortcomings such as slow execution speed and difficulty in analysis. In order to overcome such disadvantages, bytecode analysis and optimization must be performed. We implements CTOC for optimized codes. An extended CFG must be first created in order to analyze and optimize a bytecode. Due to unique bytecode properties, the existing CFG must be expanded according to the bytecode. Furthermore, the CFG must be converted into SSA Form for a static analysis, for which calculation is required for various information such as the dominate relation, dominator tree, immediate dominator, $\phi$-function, rename, and dominance frontier. This paper describes the algorithm and the process for converting the existing CFG into the SSA From. The graph that incorporates the SSA Form is later used for type inference and optimization.

Static Type Inference Based on Static Single Assignment for Bytecode (바이트코드를 위한 정적 단일 배정문 기반의 정적 타입 추론)

  • Kim Ji-Min;Kim Ki-Tea;Kim Je-Min;Yoo Weon-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.87-96
    • /
    • 2006
  • Although bytecode has many good features, it has slow execution speed and it is not an ideal representation for program analysis or optimization. For analysises and optimizations. bytecode must be translated to a Static Single Assignment Form(SSA Form) But when bytecode is translated a SSA Form it has lost type informations of son variables. For resolving these problem in this paper, we create extended control flow graph on bytecode. Also we convert the control flow graph to SSA Form for static analysis. Calculation about many informations such as dominator, immediate dominator. dominance frontier. ${\phi}$-Function. renaming are required to convert to SSA Form. To obtain appropriate type for generated SSA Form, we proceed the followings. First. we construct call graph and derivation graph of classes. And the we collect information associated with each node. After finding equivalence nodes and constructing Strongly Connected Component based on the collected informations. we assign type to each node.

  • PDF

A Study on the Validation of the Collision Avoidance System for Small-size Vessels (소형 선박의 충돌 회피 시스템 검증에 관한 연구)

  • Pyun, Jang-Hoon;Ryu, Sung-Gon;Kim, In-Seob
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1023-1030
    • /
    • 2021
  • Korea Maritime Safety Tribunal (KMST) statistics released in of 2019 indicated that most collision accidents involving small-size vessels with less than 20 gross-tonnage occur mainly due to operational carelessness, such as forward-looking negligence and unskilled vessel control. As an effective remedy, training and education for vessel operators are being strengthened to prevent accidents. However, collision accidents are increasing, and technical measures are continuously developed to reduce accidents caused by human factors. In this study, an avoidance algorithm and prototype of terminal-controller against collision between two nearby vessels was developed for implementation on relative navigation control by adopting WAVE telecommunication technology. Moreover, several sea trial tests were performed to verify the collision avoidance algorithm and control system using two fishing vessels for dif erent scenarios.

Fluid Injection Simulation Considering Distinct Element Behavior and Fluid Flow into the Ground (지반내 입자거동 및 흐름을 고려한 수압작용 모델링)

  • Jeon, Je-Sung;Kim, Ki-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2008
  • It is interesting to note that distinct element method has been used extensively to model the response of micro and discontinuous behavior in geomechanics. Impressive advances related to response of distinct particles have been conducted and there were difficulties in considering fluid effect simultaneously. Current distinct element methods are progressively developed to solve particle-fluid coupling focused on fluid flow through soil, rock or porous medium. In this research, numerical simulations of fluid injection into particulate materials were conducted to observe cavity initiation and propagation using distinct element method. After generation of initial particles and wall elements, confining stress was applied by servo-control method. The fluid scheme solves the continuity and Navior-Stokes equations numerically, then derives pressure and velocity vectors for fixed grid by considering the existence of particles within the fluid cell. Fluid was injected as 7-step into the assembly in the x-direction from the inlet located at the center of the left boundary under confining stress condition, $0.1MP{\alpha}\;and\;0.5MP{\alpha}$, respectively. For each simulation, movement of particles, flow rate, fluid velocity, pressure history, wall stress including cavity initiation and propagation by interaction of flulid-paricles were analyzed.

Dynamic Response Analysis of Pressurized Air Chamber Breakwater Mounted Wave-Power Generation System Utilizing Oscillating Water Column (진동수주형 파력발전 시스템을 탑재한 압축공기 주입식 방파제의 동적거동 해석)

  • Lee, Kwang-Ho;Kim, Do-Sam;Yook, Sung-Min;Jung, Yeong-Hoon;Jung, Ik-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.4
    • /
    • pp.225-243
    • /
    • 2014
  • As the economic matters are involved, applying the WEC, which is used for controlling waves as well as utilizing the wave energy on existing breakwater, is preferred rather than installing exclusive WEC. This study examines the OWC mounted on a pressurized air chamber floating breakwater regarding the functionality of both breakwater and wave-power generation. In order to verify the performance as a WEC, the velocity of air flow from pressurized air chamber to WEC has to be evaluated properly. Therefore, numerical simulation was implemented based on BEM from linear velocity potential theory as well as Boyle's law with the state equation to analyze pressurized air flow. The validity of the obtained values can be determined by comparing the previous results from numerical analysis and empirically obtained values of different shapes. In the actual numerical analysis, properties of wave deformation around OWC system mounted on fixed type and floating type breakwaters, motions of the structure with air flow velocities are investigated. Since, the wind power generating system can be hybridized on the structure, it is expected to be applied on complex power generation system which generates both wind and wave power energy.

Dynamic Response Analysis of Pneumatic Floating Breakwater Mounted Wave-power Generation System of Oscillating Water Column (진동수주형 파력발전시스템을 탑재한 공기주입식 부유식방파제의 동적거동해석)

  • Lee, Kwang-Ho;Kim, Do-Sam;Jung, Ik-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.305-314
    • /
    • 2017
  • Ocean wave energy harvesting is still too expensive despite developing a variety of wave energy converter (WEC) devices. For the cost-effective wave energy harvesting, it can be an effective measure to use existing breakwaters or newly installed breakwaters for both wave control and energy harvesting purposes. In this study, we investigated the functionality of both breakwater and wave-power generator for the oscillating water column (OWC)-type wave energy converter (WEC) installed in a pneumatic floating breakwater, which was originally developed as a floating breakwater. In order to verify the performance of the breakwater as a WEC, the air flow velocity from air-chamber to WEC has to be evaluated properly. Therefore, air flow velocity, wave transformation and motion of floating structure was numerically implemented based on BEM from linear velocity potential theory without considering the compressibility of air within the chamber. Air pressure, meanwhile, was assumed to be fluctuated by the motions of structure and the water level change within air-chamber. The validity of the obtained values can be determined by comparing the previous results from the numerical analysis for different shapes. Based on numerical model results, wave transformation characteristics around OWC system mounted on the fixed and floating breakwaters, and motions of the structure with air flow velocities are investigated. In summary, all numerical results are almost identical to the previous research considering air compressibility. Therefore, it can be concluded that this analysis not considering air compressibility in the air chamber is more efficient and practical method.

ITO, PR, 격벽 재료의 레이저 직접 미세가공

  • Lee, Cheon;Lee, Gyung-Chul;Ahn, Min-Young;Lee, Hong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.80-80
    • /
    • 1999
  • 플라즈마 디스플레이 패널(PDP)의 공정을 간단히 하기 위하여 포토레지스트, ITO, 격벽재료를 Ar+ laser(λ-514 nm, CW)와 Nd:YAG laser(λ=532, 266nm, pulse)로 직접 패터닝 하였다. 레이저에 의한 포토레지스트의 패턴결과, 아르곤 이온 레이저의 포토레지스트 가공의 반응 메카니즘은 레이저 빔의 열에 의한 시료 표면의 국부적인 온도상승에 의한 용융작용이며, 그 결과 식각 후 형성된 패턴의 단면 모양도 레이저빔의 profile과 같은 가우시안 형태를 나타낸다. Nd:YAG 레이저의 4고조파(532nm)를 이용한 경우 200$\mu\textrm{m}$/sce의 주사속도에서 포토레지스트를 패턴하기 위한 임계에너지(threshold energy fluence) 값은 25J/cm2이며, 약 40J/cm2의 에너지 밀도에서 하부기판의 손상이 발생하기 시작하였다. 글미 1은 Nd:YAG 레이저 4고조파를 이용하여 포토레지스트를 식각한 경우 SEM 표면사진(위)과 단차특정기에 의한 단면형상(아래)이다. ITO 막의 레이저에 의한 직접 패턴 결과, ITO 막은 레이저 펄스에 의한 급속 가열 및 증발에 의한 메커니즘으로 식각이 이루어지며, 레이저 파장에 따른 광흡수 정도의 차이에 의해 2고조파 (532nm)에서 ITO 막의 가공 품질이 4고조파(266nm)에 비해 우수하며 패턴의 폭도 출력에 따라 제어가 용이하였다. 그림 2는 Nd:YAG 레이저 2고조파를 이용하여 ITO를 식각한 경우 SEM표면 사진(위)과 단차측정기에 의한 단면형상(아래)이다. 격벽 재료의 레이저에 의한 직접 패턴 결과, Ar+ 레이저(514nm)는 출력 밀도 32NW/cm2에서 격벽을 유리 기판의 경계면까지 식각하였다. Nd:YAG 레이저(532nm)는 laser fluence가 6.5mJ/cm2에서 격벽을 식각하기 시작하였으며, 19.5J/cm2에서 유리기판의 rudraus(격벽 두께 130$\mu\textrm{m}$)까지 식각하였다.

  • PDF