• Title/Summary/Keyword: 소화가스

Search Result 426, Processing Time 0.02 seconds

Pretreatment of Waste-activated Sludge for Enhancement of Methane Production (메탄발효 효율향상을 위한 하.폐수 슬러지의 전처리 기술)

  • NamKung, Kyu-Cheol;Jeon, Che-Ok
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.362-372
    • /
    • 2010
  • Although different disposal routes of waste-activated sludge are possible, anaerobic digestion plays an important role for its abilities to further transform organic matter into methane. The potential of using methane as energy source has long been widely recognised and the present paper extensively reviews the principles of anaerobic digestion, the process parameters and hydrolysis. Hydrolysis is recognised as rate-limiting step in the complex digestion process. To accelerate the digestion and enhance the production of biogas, various pre-treatments can be used to improve the rate-limiting hydrolysis. These treatments include mechanical, thermal, chemical and biological interventions to the feedstock. All pre-treatments result in a lysis or disintegration of sludge cells, thus releasing and solubilizing intracellular material into the water phase and transforming refractory organic material into biodegradable species. The reader will finally be guided to extensive discussion for anaerobic digestion processes.

Comparative Environmental Effects of Digestates Application to the Rice Paddy Soil in Bioenergy Village : Field trial (저탄소녹색마을내 혐기소화액 순환이용에 대한 논토양 환경 영향 비교)

  • Hong, Seung-Gil;Shin, JoungDu;Kwon, Soon-Ik;Park, Woo-Kyun;Heo, Jeong-Wook;Bang, Hea-Son;Yoon, Youngman;Kang, Kee-Kyung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.1
    • /
    • pp.123-130
    • /
    • 2011
  • Objectives of this study were to compare the environmental effects of digestates produced in bioenergy village on the rice paddy field for recycling. Digestates were applied to the soils and the soil properties and the crop responses were analyzed according to the standard methods of soil evaluation. Plant height and the number of tiller showed similar results in both the conventional and digestate treated field, and the yield of rough rice was higher in the field treated with digestates than that with chemical fertilizer. The amounts of nitrogen absorbed in straw and grain were larger in the digestates-treated field than chemical fertilizer-treated one, and efficiency of nitrogen applied was shown to be the highest in 100% treated digestate of the pig manure. Exchangeable cation and pH increased in the soil treated with digestate after harvesting, but salt was not accumulated. With these results, it was concluded that resource recycling in green town can be facilitated through the securement of arable lands for the application of digestates and the proper use of these fertilizers. Long-term effects of digestate application on the soil environment should be sustainingly studied.

Development of Land Fill Gas(LFG)-MGT Power Generation and Green House Design Technology (쓰레기 매립지 MGT 발전 및 유리온실 설계기술개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2011
  • The high fuel flexibility of Micro Gas Turbine(MGT) has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and landfill as a fuel for gas turbines has increased. We researched the influence of firing landfill gas(LFG) on the performance and operating characteristics of a micro gas turbine combined heat and power system. $CH_4$ and $CO_2$ simultaneous recovery process has been developed for field plant scale to provide an isothermal, low operating cost method for carrying out the contaminants removal in Land Fill Gas(LFG) by liquid phase catalyst for introduce into the green house for the purpose of $CO_2$ rich cultivation of the plants. Methane purification and carbon dioxide stripping by muti panel autocirculation bubble lift column reactor utilizing Fe-EDTA was conducted for evaluate optimum conditions for land fill gas. Based on inflow rate of LFG as 0.207 $m^3$/min, 5.5 kg/$cm^2$, we designed reactor system for 70% $CH_4$ and 27% $CO_2$ gas introduce into MGT system with $H_2S$ 99% removal efficiency. A green house designed for four different carbon dioxide concentration from ambient air to 1500 ppm by utilizing the exhaust gas and hot water from MGT system.

A Study on the Development of Fire Extinguishing Agent and Extinguishing System for ESS Fire (ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구)

  • Lee, Yeon-Ho;Lee, Joo-Hyung;Kim, Soo-Jin;Chon, Sung-Ho;Choi, Byoung-Chul;Oh, Seung-Ju;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.147-155
    • /
    • 2020
  • This paper presents a study on the development of a fire extinguishing agent and extinguishing system for an energy storage system (ESS) fire. The fire extinguishing agent designed to extinguish an ESS fire is a highly permeable fire extinguisher that reduces the surface tension and viscosity while bringing about cooling action. This is the main extinguishing effect of this type of wetting agent, which displays the characteristics of fire extinguishing agents used for penetrating the battery cells inside the ESS module. For the fire extinguishing system, a local application system was designed to suppress fire on a rack-by-rack basis. A 360° rotating nozzle was inserted into the rear hall of the ESS module, and general nozzles were installed in the rack to maximize the fire extinguishing effect. The fire extinguishing agent was strongly discharged by virtue of the gas release pressure. Experiments on fire suppression performance with ESS module 1 unit and module 3 units showed that all visible flames were extinguished in 8 s and 9 s, respectively, by the fire extinguishing agent. In addition, based on confirming reignition for 600 s after the fire extinguishing agent was exhausted, it was confirmed that the ESS fire was completely extinguished without reignition in all fire suppression performance experiments.

The Effects of the Area of Openings on the Performance of a $CO_2$ Extinguishing System -The CFD Simulations of the Oil Surface Fire in a Machine Room- (개구부 면적이 $CO_2$ 소화설비의 소화성능에 미치는 영향 -기계실 석유 표면화재의 CFD simulations-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Park, Jong-Tack
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Carbon dioxide($CO_2$) agent, which has more safely extinguished fire than any other gaseous fire extinguishing agents, has been widely used in various protected enclosures and types of fires. According to the concept of performance-based design(PBD). $CO_2$ extinguishing system to be designed is needed to be evaluated for the performance of fire suppression with possible fire scenarios in an enclosure. In this paper, CFD simulations were carried out to study the effects of opening area on the performance of $CO_2$ extinguishing system and the flow characteristics in the machine room of $100m^3$ in which kerosene spill fire happened. This study showed that time of fire suppression increased linearly in proportion to the size of opening area, and fires for each model were completely suppressed prior to the end of discharge of $CO_2$ agent. It was shown that mass flow rate through opening was influenced by the combined effects of heat release rate of fire and discharge of $CO_2$ agent. After $CO_2$ agent was completely discharged, oxygen concentrations in enclosures for each model were lower than the limit concentration of combustion.

Study on the Safety Standard Establishment of Halogen Clean Extinguishing Agents (할로겐화합물청정소화약제 안전기준 설정에 관한 연구)

  • Cho, Jung-Rae;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.22-33
    • /
    • 2018
  • The amount of halogen clean fire extinguishing agents has been increased by the excellent features of extinguishing, adaptability and no residue. On the other hand in situations without a hazard assessment and safety standard of agents, chemical accidents by the agents occurs frequently. This study was performed to propose the halogen clean agents' regulatory exposure limit and safety standard including the quantitative ventilation system with gas leak monitoring, hazard recognition and optimal personal protection selection through a literature review and experimental research.

Effects of Complex Probiotic Supplementation on Growth Performance, Nutrient Digestibility, Blood Metabolites, Noxious Gas and Fecal Microflora in Weaning Pigs (사료 내 복합생균제 첨가가 이유자돈의 사양성적, 영양소 소화율, 혈액성상, 분내 유해가스 및 분 중 미생물에 미치는 영향)

  • Kim, Dong-Woo;Choi, Yo-Han;Kim, Jo-Eun;Cho, Eun Seok;Jung, Hyun-Jung;Oh, Seung-Min;Kim, Jeong-Dae;Kim, Jin-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.266-273
    • /
    • 2020
  • This study was undertaken to determine the effects of diet supplementation with complex probiotics (CPB), on growth performance, nutrient digestibility, blood metabolites, noxious gas, and fecal microflora in weaning pigs. On the basis of body weight, a total of 234 weaned pigs (Landrace×Yorkshire×Duroc, 6.14±0.78kg) were randomly allotted to 3 treatments and 6 replicates (13 pigs per pen). The experimental diets were fed in a meal form for 28 days (days 0-14, PhaseI, and days 15-28, PhaseII). The dietary treatment groups were as follows: T1 (basal diet), T2 (T1+0.13% CPB) and T3 (T1+0.25% CPB). The CPB supplement contained Bacillus subtilis 1.0×106 CFU/g, Enterococcus faecium 1.0×106 CFU/g, Saccharomyces cerevisiae 1.0×106 CFU/g, Bacillus licheniformis 3.0×108 CFU/g, and Bacillus polyfermenticus 3.0×108 CFU/g. Pigs fed the T3 diet showed an increase (p<0.05) in the overall average daily gain and average daily feed intake, increased (p<0.05) crude protein digestibility in PhaseI, and greater (p<0.05) dry matter and gross energy digestibility in PhaseII. Supplementation of CPB had no effect on the blood profile. Furthermore, pigs fed the T3 diet had lower (p<0.05) NH3 emission and overall count of fecal Clostridium spp. In conclusion, we believe that CPB supplementation has a beneficial effect on growth performance, nutrient digestibility, noxious gas, and fecal microflora in weaning pigs.

Effects of Biogas Composition Variations on Engine Performance (바이오가스의 성분 변화가 엔진 성능에 주는 영향)

  • Park, Seung-Hyun;Park, Cheol-Woong;Kim, Young-Min;Lee, Sun-Youp;Kim, Chang-Gi
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.25-30
    • /
    • 2011
  • Biogas obtained from the biodegradable organic wastes in an anaerobic digester consists of $CH_4$ and inert gases such as $CO_2$ and $N_2$. Since the composition of biogas varies by anaerobic digester conditions and the origin of wastes, it is necessary to respond to these variations so as to make stable combustion and accomplish high efficiency when it is used as a fuel for power generating SI engines. In this study, efforts have been made to investigate the effect of changes in the calorific values of biogas on the engine performance and exhaust characteristics. The biogas was simulated by supplying of $CH_4$ with $N_2$ dilution of various ratios, and ECM was developed to achieve accurate control of ignition and combustion. The results show that as the $CH_4$ concentration of the biogas decreases, the optimal spark timing is advanced due to the elevated thermal capacity and lowered $O_2$ concentration of the in-cylinder charge. Furthermore, since combustion temperature was reduced by increased inert gas, $NO_x$ emissions decreased, whereas THC emissions increased.

Feasibility of Co-Digestion of Sewage Sludge, Swine Waste, and Food Waste Leachate (하수슬러지, 돈분뇨, 음식물쓰레기 탈리액 병합소화 타당성 평가)

  • Kim, Sang-Hyoun;Ju, Hyun-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Feasibility of co-digestion was investigated by a series of anaerobic batch experiments using sewage sludge, swine waste, and food waste leachate as substrates. The organic solid wastes were collected from M city, where the daily productions of sewage sludge, swine waste, and food waste leachate were 178 ton/d, 150 ton/d, and 8 ton/d, respectively. Both swine waste and food waste leachate showed superior methane yields, methane productivities, and organic pollutant removal efficiencies compared to sewage sludge. Co-digestion of the total amounts of organic solid wastes would enhance methane production by 5.60 times $(530\;m^{3}\;CH_{4}/d\;{\rightarrow}\;2,968\;m^{3}\;CH_{4}/d)$. However, it also increase the amount of digestate by 1.88 times with 3.79 to 4.92 times higher pollutants (chemical oxygen demands total nitrogen, and total phosphorus) loading rates. Co-digestion of organic solid wastes is a valid strategy to enhance the performance of an anaerobic sludge digester and the energy independence of a wastewater treatment plant. Anyhow,the increment of digestate with higher pollutant loading would need a careful counterplan in the operation of the main stream of the treatment plant.

Development of a Biogas Engine for Cogeneration System (바이오스가스를 이용한 열병합 발전용 엔진 개발)

  • Kim, Yeong-Min;Lee, Jang-Hui;Ju, Seong-Ho
    • 연구논문집
    • /
    • s.30
    • /
    • pp.33-42
    • /
    • 2000
  • We must stabilize quickly increasing waste matters in urban life and livestock industry. Biogas including landfill gas and digester gas is byproduct of anaerobic decomposition of organic waste matter and contains 40%-70% methane, which can be used for energy purposes. Utilization of biogas reduce the emission of methane into the atmosphere to minimize greenhouse effect and the carbon dioxide (CO2) emitted when biogas is converted to energy has been taken out of the atmosphere by growing plant. Recently, bioenergy is world-widely noticeable as all contributing to the greenhouse effect. This paper presents development process of a biogas engine for cogeneration system and results of application to digester gas and landfill gas in site. The biogas engine is a dual fuel engine operated on biogas with a diesel pilot. At present, the engine can substitute biogas for diesel fuel up to 85%. but it can be said that there is a possibility of improvement in performance.

  • PDF