• Title/Summary/Keyword: 소프트 렌즈

Search Result 124, Processing Time 0.026 seconds

The Change of Blink Rate by Wearing Soft Contact Lens (소프트콘택트렌즈 착용에 의한 순목 횟수 변화)

  • Lee, Youn-Jin;Park, Sang-Il;Lee, Heum-Sook;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.173-179
    • /
    • 2006
  • We investigated the change of the blink rate by wearing soft contact lens(SCL). Eight types of soft contact lenses were worn by twelve asymptomatic contact lens wearers. When wearers were worn SCLs for 15 min, the average blink rate was 20.0 blinks/min, which was a statistically significant increase compared to 13.3 blinks/min, the average blink rate of non-SCL-worn eye. After 8 hr of lens wear, the average blink rate was 24.3 blinks/min, and it was 11 blinks/min more than that of non-SCL-worn eye and 4 blinks/min more than that of 15 min SCL-worn eye. There were a little difference of the blink rate in types of lens, which the blink rate range of all lens after 15 min of lens wear was 18.1~20.9 blinks/min and that after 8 hr of lens wear was 22.9~24.9 blinks/min. When wearing A lens(vifilcon, 0.06 mm) having thin center thickness, wearers showing difference of 10.0~11.9 blinks/min between non-SCL-worn eye and 15 min SCL-worn eye reached 16.7% and it was more than that of relatively thick B lens(0.17 mm) and C lens(0.14 mm). This result suggest that the center thickness was not unique factor of the blink rate change and other factors would have synthetically influence on the blink rate change. In the case of B lens and C lens of hilafilcon material but having different center thickness and water content, wearers increasing more than 4.0 blinks/min after 8 hr of lens wear was 58.3% and 41.7%, respectively. This result have provided information that the lenses of similar materials but different center thickness and water content could cause individually the different change of the blink rate.

  • PDF

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF

The Evaluation of Property of Colored Contact Lenses (칼라콘택트렌즈의 물성적 특성 평가)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.119-126
    • /
    • 2005
  • The purpose of this study was analyzed to compare on the physical characters of two companies of color contact lenses. Artificial tear solution was used for measuring the rate of protein deposits and wettability. The surface roughness of lenses was measured by SEM(scanning electron microscope, Japan) and AFM(atomic force microscope, MultimodeTM, USA). As a results, The color contact lenses was not different from general soft contact lenses in a respect of other properties. However, the colored contact lenses showed a severe crack on the surface under SEM observation. There was no irregularity on the surface of the colored contact lenses in AFM photograph. The dyes were deposited in inside of lenses by microscope observation.

  • PDF

Usefulness of Rotation for Toric Soft Lenses Using Objective Refraction (타각적 굴절검사를 이용한 토릭 소프트 렌즈 회전 평가의 유용성)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.265-272
    • /
    • 2011
  • Purpose: The clinical usefulness of rotation evaluation using objective refraction in toric soft lenses fitting was investigated. Methods: Toric soft lenses were fitted for 32 subjects (64 eyes; mean age of 24.69 ${\pm}$ 1.65 years) with astigmatism and both eyes of each subject were fitted with toric soft lenses. Objective refraction-based lenses rotation was evaluated from refraction and over-refraction data by indirect calculating technique. These calculated data were compared with the measured data from slit lamp with direct measuring technique. Results: Orientation of toric soft lenses around zero position (within ${\pm}$ 5$^{\circ}$ vertical line) was investigated. The orientations to the direction of nose of measured and calculated values were 69.78% and 63.64%, respectively, which showed similar values between two techniques. Agreement frequency between measured and calculated values in the magnitude of lenses rotation 54.69% and 82.82% for 10$^{\circ}$ and 20$^{\circ}$ of vertical line, respectively. The 95% limits of agreement between calculation and measurement were from -10.08$^{\circ}$ to 12.65$^{\circ}$, and mean difference was 1.29$^{\circ}$ within ${\pm}$ 10$^{\circ}$. The result showed there was no significant difference (p = 0.1984) and high correlation (r = 0.56, p = 0.0004) between two techniques. But the 95% limits of agreement was widen in ${\pm}$ 20$^{\circ}$ of vertical line. The magnitude of lens rotation between two methods was 9.66 ${\pm}$ 6.16$^{\circ}$, 16.17 ${\pm}$ 12.38$^{\circ}$ and 10.58 ${\pm}$ 12.02$^{\circ}$ for normal, loose and tight fitted conditions. Conclusions: From the results with smaller difference between two techniques, it was found that higher availability of subjective over-refraction data can be used as a supplementary tool for subjective refraction. An application using objective refraction with direct measuring could be provide high success in prescription on toric soft lenses.

CAE 해석결과를 반영한 플라스틱 렌즈의 광선추적 기법

  • Park, Geun;Lee, Sang-Kyu;Mo, Pil-Sang;Jeon, Kwang-Sik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.51-51
    • /
    • 2004
  • 렌즈는 광학제품의 성능에 직접적인 영향을 미치는 주요 부품으로서, 고정도의 형상 및 안정된 내부물성을 요구하는 정밀 부품이다. 광학 렌즈는 특정 광학계 내에서 입사광이 원하는 위치에 초점을 맺을 수 있도록 굴절시켜주는 역할을 하며, 이를 위해 초점거리, 배율, 렌즈의 성능 등을 종합적으로 고려하여 렌즈의 형상을 설계해야 한다. 이러한 설계과정은 기하광학에 기반한 광선추적(Ray tracing) 기법을 통해 이루어지며, 주로 CodeV, OSLO 등의 상용 광학계설계 소프트웨어를 사용하여 수행되고 있다.(중략)

  • PDF

ZOOM-IN - (주)싸이펨 민제홍 대표이사 취임 인터뷰

  • 한국광학기기산업협회
    • The Optical Journal
    • /
    • s.177
    • /
    • pp.28-29
    • /
    • 2020
  • 미국 Synopsys의 광학 설계 분석 소프트웨어의 국내 판매와 기술지원, 교육, 광학설계 컨설팅 서비스와 기하광학에서 파동광학까지 폭넓게 아우르는며, LightTools(조명), CODE V(렌즈), LucidShape(자동차 조명), RSoft(나노 사이즈 광학구조) 네 가지 분야 소프트웨어와 광학 설계 솔루션을 보유한 광학 전문기업 (주)싸이펨이 지난 1월 민제홍 대표이사가 새로 취임하며 변화를 꾀하고 있다.

  • PDF

Conversion of Camera Lens Distortions between Photogrammetry and Computer Vision (사진측량과 컴퓨터비전 간의 카메라 렌즈왜곡 변환)

  • Hong, Song Pyo;Choi, Han Seung;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.4
    • /
    • pp.267-277
    • /
    • 2019
  • Photogrammetry and computer vision are identical in determining the three-dimensional coordinates of images taken with a camera, but the two fields are not directly compatible with each other due to differences in camera lens distortion modeling methods and camera coordinate systems. In general, data processing of drone images is performed by bundle block adjustments using computer vision-based software, and then the plotting of the image is performed by photogrammetry-based software for mapping. In this case, we are faced with the problem of converting the model of camera lens distortions into the formula used in photogrammetry. Therefore, this study described the differences between the coordinate systems and lens distortion models used in photogrammetry and computer vision, and proposed a methodology for converting them. In order to verify the conversion formula of the camera lens distortion models, first, lens distortions were added to the virtual coordinates without lens distortions by using the computer vision-based lens distortion models. Then, the distortion coefficients were determined using photogrammetry-based lens distortion models, and the lens distortions were removed from the photo coordinates and compared with the virtual coordinates without the original distortions. The results showed that the root mean square distance was good within 0.5 pixels. In addition, epipolar images were generated to determine the accuracy by applying lens distortion coefficients for photogrammetry. The calculated root mean square error of y-parallax was found to be within 0.3 pixels.

The Effects of Drugs, including Alcohol, on Ocular Health and Contact Lens Wear (약물과 알코올이 눈과 콘택트렌즈에 미치는 영향)

  • Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.73-81
    • /
    • 2000
  • This review on ocular toxicology concentrates on the effects on ocular health and contact lens wear induced by systemically used drugs, including alcohol. Many systemically administered drugs produce ocular adverse effects. Fortunately, relatively few are capable of causing significant, irreversible visual impairment. The visual symptoms of acute intoxication are as follows : Drop in vision/visual acuity, diplopia, poor dark adaptation, increase in time for glare recovery, early cataract, decreased depth perception, blue-yellow or red-green colour defect and visual hallucinations. Blinking pattern, tear production, and discoloration of contact lenses can be affected by some systemic or local ocular medications. The cornea, conjunctiva, or eyelids may react to some systemic medications and to some preservatives used in contact lens solutions. The hydrogel contact lens act as a drug reservoir that emits the drug over time. I discuss management of contact lens-induced infectious and inflammatory conditions.

  • PDF