• Title/Summary/Keyword: 소프트웨어 연구개발

Search Result 4,395, Processing Time 0.152 seconds

A Study on the Realities and the Subject of Environmental Management for Small and Medium-Sized Companies in Gangwon Area (강원지역 중소기업의 환경경영 실태와 과제)

  • Jeon, Yeong-Seung;Park, Eun-Jeong
    • Korean Business Review
    • /
    • v.17
    • /
    • pp.53-81
    • /
    • 2004
  • The purpose of this study is to understand the realities and the subject of environmental management for small and medium-sized companies in Gwangwon area, through surveying the present status as to acquiring the certification of ISO14001, and to seek for a plan to facilitate environmental management. Given summarizing key results, those are as follows. First, while the number of companies in our country which acquired the certification of ISO14001, amounts to 1,215 businesses as of April of 2003, the number of small and medium-sized companies in Gwangwon area which obtained the certification of ISO14001 reached only 26 businesses, the lowest level among metropolitan municipalities. Second, for the reason that companies who didn't acquire the certification, strive not to receive the certification, it did present the point that' costs to be needed in acquiring and maintaining the certification are larger than practical benefit. Third, the biggest reason for either companies which did not acquire the certification of ISO14001 or companies which did (try to) acquire the certification of ISO1400, was, enhancement of a corporate image,' and the effect after a company who obtained the certification introduced the environmental management system, was also shown to be 'the improvement of a corporate image.' Fourth, many companies who acquired the certification of ISO1400 pointed out the response related to 'burden on document creation and costs' and 'lack of manpower' as problems when introducing the environmental management system. On the basis of major results of a study as the above, given presenting the subject and a plan for activating the environmental management of small and medium-sized companies in Gwangwon area, those are as follows. First, because most of companies who did not obtain the certification of ISO1400 have low recognition of ISO14001, it needs continuous and positive publicity, education and a training system. Second, it requires to carry out an educational program to nurture professional manpower due to lack of manpower relevant to environmental management, to expand payment of subsidies, to open exclusive-charge department and consulting contact, to have the relevant information be database and to develop software. Third, in order to make the certification obtained through inexpensive costs and simple procedures, it needs to positively consider the creation of public approval system for a small and medium-sized company, group approval system, industrial-complex approval system, and others.

  • PDF

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

On-Line Determination Steady State in Simulation Output (시뮬레이션 출력의 안정상태 온라인 결정에 관한 연구)

  • 이영해;정창식;경규형
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1996.05a
    • /
    • pp.1-3
    • /
    • 1996
  • 시뮬레이션 기법을 이용한 시스템의 분석에 있어서 실험의 자동화는 현재 많은 연구와 개발이 진행 중인 분야이다. 컴퓨터와 정보통신 시스템에 대한 시뮬레이션의 예를 들어 보면, 수많은 모델을 대한 시뮬레이션을 수행할 경우 자동화된 실험의 제어가 요구되고 있다. 시뮬레이션 수행회수, 수행길이, 데이터 수집방법 등과 관련하여 시뮬레이션 실험방법이 자동화가 되지 않으면, 시뮬레이션 실험에 필요한 시간과 인적 자원이 상당히 커지게 되며 출력데이터에 대한 분석에 있어서도 어려움이 따르게 된다. 시뮬레이션 실험방법을 자동화하면서 효율적인 시뮬레이션 출력분석을 위해서는 시뮬레이션을 수행하는 경우에 항상 발생하는 초기편의 (initial bias)를 제거하는 문제가 선결되어야 한다. 시뮬레이션 출력분석에 사용되는 데이터들이 초기편의를 반영하지 않는 안정상태에서 수집된 것이어야만 실제 시스템에 대한 올바른 해석이 가능하다. 실제로 시뮬레이션 출력분석과 관련하여 가장 중요하면서도 어려운 문제는 시뮬레이션의 출력데이터가 이루는 추계적 과정 (stochastic process)의 안정상태 평균과 이 평균에 대한 신뢰구간(confidence interval: c. i.)을 구하는 것이다. 한 신뢰구간에 포함되어 있는 정보는 의사결정자에게 얼마나 정확하게 평균을 추정할 구 있는지 알려 준다. 그러나, 신뢰구간을 구성하는 일은 하나의 시뮬레이션으로부터 얻어진 출력데이터가 일반적으로 비정체상태(nonstationary)이고 자동상관(autocorrelated)되어 있기 때문에, 전통적인 통계적인 기법을 직접적으로 이용할 수 없다. 이러한 문제를 해결하기 위해 시뮬레이션 출력데이터 분석기법이 사용된다.본 논문에서는 초기편의를 제거하기 위해서 필요한 출력데이터의 제거시점을 찾는 새로운 기법으로, 유클리드 거리(Euclidean distance: ED)를 이용한 방법과 현재 패턴 분류(pattern classification) 문제에 널리 사용 중인 역전파 신경망(backpropagation neural networks: BNN) 알고리듬을 이용하는 방법을 제시한다. 이 기법들은 대다수의 기존의 기법과는 달리 시험수행(pilot run)이 필요 없으며, 시뮬레이션의 단일수행(single run) 중에 제거시점을 결정할 수 있다. 제거시점과 관련된 기존 연구는 다음과 같다. 콘웨이방법은 현재의 데이터가 이후 데이터의 최대값이나 최소값이 아니면 이 데이터를 제거시점으로 결정하는데, 알고기듬 구조상 온라인으로 제거시점 결정이 불가능하다. 콘웨이방법이 알고리듬의 성격상 온라인이 불가능한 반면, 수정콘웨이방법 (Modified Conway Rule: MCR)은 현재의 데이터가 이전 데이터와 비교했을 때 최대값이나 최소값이 아닌 경우 현재의 데이터를 제거시점으로 결정하기 때문에 온라인이 가능하다. 평균교차방법(Crossings-of-the-Mean Rule: CMR)은 누적평균을 이용하면서 이 평균을 중심으로 관측치가 위에서 아래로, 또는 아래서 위로 교차하는 회수로 결정한다. 이 기법을 사용하려면 교차회수를 결정해야 하는데, 일반적으로 결정된 교차회수가 시스템에 상관없이 일반적으로 적용가능하지 않다는 문제점이 있다. 누적평균방법(Cumulative-Mean Rule: CMR2)은 여러 번의 시험수행을 통해서 얻어진 출력데이터에 대한 총누적평균(grand cumulative mean)을 그래프로 그린 다음, 안정상태인 점을 육안으로 결정한다. 이 방법은 여러 번의 시뮬레이션을 수행에서 얻어진 데이터들의 평균들에 대한 누적평균을 사용하기 매문에 온라인 제거시점 결정이 불가능하며, 작업자가 그래프를 보고 임의로 결정해야 하는 단점이 있다. Welch방법(Welch's Method: WM)은 브라운 브리지(Brownian bridge) 통계량()을 사용하는데, n이 무한에 가까워질 때, 이 브라운 브리지 분포(Brownian bridge distribution)에 수렴하는 성질을 이용한다. 시뮬레이션 출력데이터를 가지고 배치를 구성한 후 하나의 배치를 표본으로 사용한다. 이 기법은 알고리듬이 복잡하고, 값을 추정해야 하는 단점이 있다. Law-Kelton방법(Law-Kelton's Method: LKM)은 회귀 (regression)이론에 기초하는데, 시뮬레이션이 종료된 후 누적평균데이터에 대해서 회귀직선을 적합(fitting)시킨다. 회귀직선의 기울기가 0이라는 귀무가설이 채택되면 그 시점을 제거시점으로 결정한다. 일단 시뮬레이션이 종료된 다음, 데이터가 모아진 순서의 반대 순서로 데이터를 이용하기 때문에 온라인이 불가능하다. Welch절차(Welch's Procedure: WP)는 5회이상의 시뮬레이션수행을 통해 수집한 데이터의 이동평균을 이용해서 시각적으로 제거시점을 결정해야 하며, 반복제거방법을 사용해야 하기 때문에 온라인 제거시점의 결정이 불가능하다. 또한, 한번에 이동할 데이터의 크기(window size)를 결정해야 한다. 지금까지 알아 본 것처럼, 기존의 방법들은 시뮬레이션의 단일 수행 중의 온라인 제거시점 결정의 관점에서는 미약한 면이 있다. 또한, 현재의 시뮬레이션 상용소프트웨어는 작업자로 하여금 제거시점을 임의로 결정하도록 하기 때문에, 실험중인 시스템에 대해서 정확하고도 정량적으로 제거시점을 결정할 수 없게 되어 있다. 사용자가 임의로 제거시점을 결정하게 되면, 초기편의 문제를 효과적으로 해결하기 어려울 뿐만 아니라, 필요 이상으로 너무 많은 양을 제거하거나 초기편의를 해결하지 못할 만큼 너무 적은 양을 제거할 가능성이 커지게 된다. 또한, 기존의 방법들의 대부분은 제거시점을 찾기 위해서 시험수행이 필요하다. 즉, 안정상태 시점만을 찾기 위한 시뮬레이션 수행이 필요하며, 이렇게 사용된 시뮬레이션은 출력분석에 사용되지 않기 때문에 시간적인 손실이 크게 된다.

  • PDF

Conjunction Assessments of the Satellites Transported by KSLV-II and Preparation of the Countermeasure for Possible Events in Timeline (누리호 탑재 위성들의 충돌위험의 예측 및 향후 상황의 대응을 위한 분석)

  • Shawn Seunghwan Choi;Peter Joonghyung Ryu;John Kim;Lowell Kim;Chris Sheen;Yongil Kim;Jaejin Lee;Sunghwan Choi;Jae Wook Song;Hae-Dong Kim;Misoon Mah;Douglas Deok-Soo Kim
    • Journal of Space Technology and Applications
    • /
    • v.3 no.2
    • /
    • pp.118-143
    • /
    • 2023
  • Space is becoming more commercialized. Despite of its delayed start-up, space activities in Korea are attracting more nation-wide supports from both investors and government. May 25, 2023, KSLV II, also called Nuri, successfully transported, and inserted seven satellites to a sun-synchronous orbit of 550 km altitude. However, Starlink has over 4,000 satellites around this altitude for its commercial activities. Hence, it is necessary for us to constantly monitor the collision risks of these satellites against resident space objects including Starlink. Here we report a quantitative research output regarding the conjunctions, particularly between the Nuri satellites and Starlink. Our calculation shows that, on average, three times everyday, the Nuri satellites encounter Starlink within 1 km distance with the probability of collision higher than 1.0E-5. A comparative study with KOMPSAT-5, also called Arirang-5, shows that its distance of closest approach distribution significantly differs from those of Nuri satellites. We also report a quantitative analysis of collision-avoiding maneuver cost of Starlink satellites and a strategy for Korea, being a delayed starter, to speed up to position itself in the space leading countries. We used the AstroOne program for analyses and compared its output with that of Socrates Plus of Celestrak. The two line element data was used for computation.

Association Between Structural and Functional Aspects of Social Networks and Health Promoting Behaviors: Focusing on Community-Dwelling Older Adults (사회적 관계망의 구조적, 기능적 측면과 건강증진행동과의 관계: 지역사회 거주 노인을 중심으로)

  • An, Hyunseo;Kim, Inhye;Yun, Sohyeon;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.4
    • /
    • pp.81-96
    • /
    • 2023
  • Objective : This study aimed to examine the association between the structural and functional aspects of social networks and health-promoting behaviors in community-dwelling older adults. Methods : Social networks based on structural and functional aspects and health-promoting behaviors by lifestyle were measured in 226 community-dwelling adults aged 65 years and over. To analyze the collected data, an independent t-test, one-way ANOVA, Pearson's correlation analysis, and hierarchical regression were performed. Results : The network size was the highest in the friend network, and the frequency of contact and social support was the highest in the non-living family network. Health-promoting behaviors were highest for activities of daily living and lowest for productive and social activities. All subfactors of social networks showed significant positive correlations with health-promoting behaviors. Hierarchical regression showed social support from neighbors as the variable with a significant effect on health-promoting behaviors; gender and depression were also influencing factors, and this model showed 37% explanatory power. Conclusion : To promote healthy behaviors of older adultsin the community, the development of health promotion programs and related policies considering social networks centering on social support from neighbors is required.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

Radiomics Analysis of Gray-Scale Ultrasonographic Images of Papillary Thyroid Carcinoma > 1 cm: Potential Biomarker for the Prediction of Lymph Node Metastasis (Radiomics를 이용한 1 cm 이상의 갑상선 유두암의 초음파 영상 분석: 림프절 전이 예측을 위한 잠재적인 바이오마커)

  • Hyun Jung Chung;Kyunghwa Han;Eunjung Lee;Jung Hyun Yoon;Vivian Youngjean Park;Minah Lee;Eun Cho;Jin Young Kwak
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.185-196
    • /
    • 2023
  • Purpose This study aimed to investigate radiomics analysis of ultrasonographic images to develop a potential biomarker for predicting lymph node metastasis in papillary thyroid carcinoma (PTC) patients. Materials and Methods This study included 431 PTC patients from August 2013 to May 2014 and classified them into the training and validation sets. A total of 730 radiomics features, including texture matrices of gray-level co-occurrence matrix and gray-level run-length matrix and single-level discrete two-dimensional wavelet transform and other functions, were obtained. The least absolute shrinkage and selection operator method was used for selecting the most predictive features in the training data set. Results Lymph node metastasis was associated with the radiomics score (p < 0.001). It was also associated with other clinical variables such as young age (p = 0.007) and large tumor size (p = 0.007). The area under the receiver operating characteristic curve was 0.687 (95% confidence interval: 0.616-0.759) for the training set and 0.650 (95% confidence interval: 0.575-0.726) for the validation set. Conclusion This study showed the potential of ultrasonography-based radiomics to predict cervical lymph node metastasis in patients with PTC; thus, ultrasonography-based radiomics can act as a biomarker for PTC.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Study of Web Services Interoperabiliy for Multiple Applications (다중 Application을 위한 Web Services 상호 운용성에 관한 연구)

  • 유윤식;송종철;최일선;임산송;정회경
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.217-220
    • /
    • 2004
  • According as utilization for web increases rapidly, it is demanded that model about support interaction between web-based applications systematically and solutions can integrate new distributed platforms and existing environment effectively, accordingly, Web Services appeared by solution in reply. These days, a lot of software and hardware companies try to adoption of Web Services to their market, attenpt to construct their applications associationing components from various Web Services providers. However, to execute Web Services completely. it must have interoperability and need the standardization work that avoid thing which is subject to platform, application as well as service and programming language from other companies. WS-I (Web Services Interoperability organization) have established Basic Profile 1.0 based on XML, UDDI, WSDL and SOAP for web services interoperability and developed usage scenario Profile to apply Web Services in practice. In this paper, to verify suitability Web Services interoperability between heterogeneous two applications, have design and implements the Book Information Web Services that based on the Web Services Client of J2SE platform and the Web Services Server of .NET platform, so that analysis and verify the service by adaptation of WS-I Basic Profile.

  • PDF

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.