• 제목/요약/키워드: 소음 및 진동

검색결과 2,632건 처리시간 0.021초

자동차 조립라인에서 이중-헴머형(Double-hammer type) 임펙트 렌치와 오일-펄스형(Oil-pulse type)임펙트 렌치 에어공구의 국소진동가속도 및 소음수준 (Hand-Arm Vibration and Noise Levels of Double-Hammer Type and Oil-Pulse Type Impact Wrenches in Automobile Assembly Lines)

  • 정재열;김정만
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.147-159
    • /
    • 1995
  • This study was conducted to introduce fundamental data of hand-arm vibration and noise exposure levels with impact wrenches(double-hammer impact wrenches and oil-pulse impact wrenches) used in automobile assembly lines considering the process variables and tool variables. In studing, products per day, required time screwing the bolts or nuts per bolts or nut were considered as process variables, and capacity of bolts or nuts, air consumptions per minute, tool weights, RPM were considered as tool variables. Hand-arm vibration levels of 3 axis in each hand were measured using the instruments compling with ISO/DIS 5349 and noise levels were measured using a noise logging dosimeter. The results were as follows : 1. Required time to screwing the bolt or nut by oil-pulse impact wrenches is shorter than double-hammer impact wrenches but total daily exposure time of oil-pulse impact wrenches was higher than double-hammer impact wrenches because the number of bolts or nuts per cycle was many. 2. Oil-pulse impact wrenches have been used to screwing the large bolt or nut in comparing with double-hammer impact wrenches and required time to screwing the bolts or nuts were shorter than double-hammer impact wrenches because oil-pulse impact wrenches were using high RPM and large air consumption per minute. Noise level of oil-pulse impact wrenches was 8 dB(A) lower than double-hammer impact wrenches. 3. Dominant hand-arm vibration levels of double-hammer impact wrenches in each hand were $8.24m/sec^2$ of Zh axis in right hand and $9.60m/sec^2$ of Xh axis in left hand. Dominant hand-arm vibration level of oil-pulse impact wrenches in each hand was $2.59m/sec^2$ of Xh axis in right hand and $3.23m/sec^2$ of Yh axis in left hand. 4. In double-hammer impact wrenches, corresponding hand-arm vibration levels of Xh, Yh, Zh axis in left hand were higher than hand-arm vibration levels of right hand in 3 axis. In oil-pulse impact wrenches, Xh axis of right, Yh axis of left, Zh axis of left were higher than the corresponding hand-arm vibration levels of Xh, Yh, Zh axis in right and left hand. 5. Correlation coefficients among Xh, Yh. Zh axis of right and left hand hand-arm vibration levels in double-hammer impact wrenches and oil-pulse impact wrenches were commonly high in Yh axis and correlation coefficients of Yh axis in double-hammer impact wrenches and oil-pulse impact wrenches were 0.76 and 0.86,respectively. 6. As a measure repetitiveness, plotting total daily exposure time with the number of bolts or nut per cycle, direct correlation was shown between repetitiveness and hand-arn vibration exposure, and correlation coefficient between the number of bolts or nut per cycle and total daily exposure time in double-hammer impact wrenches, oil-pulse impact wrenches were 0.84 and 0.50, respectively. 7. Considering the total acceleration level and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption in right hand, and bolt or nut capacity in left hand were commonly the variable that explainability was high. Considering the noise and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption per minute was commonly the variable that explainability was high.

  • PDF

수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구 (On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment)

  • 엄중현;이두한;김형수
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.815-824
    • /
    • 2022
  • 발전소의 주요시설 중 발전 시스템 냉각용으로 사용되는 순환수는 순환수 취수부(Circulation Water Intake Basin)를 통해 공급된다. 순환수 취수부 중 흡입수조(Pump Sump)에서 발생하는 다양한 형태의 와류는 순환수펌프(Circulation Water Pump) 및 관로에 악영향을 미친다. 특히, 공기의 흡입을 동반한 자유표면 와류는 진동, 소음, 공동현상 등을 발생시켜 순환수펌프의 성능 저하, 관로의 손상을 일으키며 발전이 중단되는 주요 원인이 된다. 따라서 수리모형 실험을 통해 순환수 취수부에 대한 수리특성을 반드시 확인하고, 와류 발생 시 와류를 제어할 수 있는 적절한 와류제어장치(Anti Vortex Device)를 적용하여 원활한 발전소 운영이 가능하도록 해야 한다. 자유표면 와류 저감을 위해 와류제어장치 중커튼월(Curtain Wall)을 사용하는 것이 일반적이며, 자세한 내용은 American National Standard for Pump Intake Design에서 기술하고 있다. 본 연구에서는 리비아 Tripoli West 4×350 MW 발전소의 순환수 취수부를 대상으로 하였으며, 실제 운영조건을 적용하고, 수리모형 실험을 통해 순환수 취수부 중 흡입수조에서 발생하는 와류제어장치의 와류저감 효과를 분석하였다. 또한, 수중와류 제어를 위해 플로어 스플리터(floor splitter)는 기본적으로 적용하였고, 자유표면에서 발생하는 와류제어를 위해 새로운 형태인 컬럼 커튼월(Column Curtain Wall)을 추가적으로 적용하여 효과를 확인하였다. 본 연구에서는 일반적으로 적용되었던 커튼월에 새로 개발한 컬럼 커튼월을 추가적으로 적용하여 수리특성을 분석한 결과, 균일한 흐름이 형성되면서 와류가 제어되는 것을 확인하였다. 또한, 순환수펌프 관로 내에서 발생하는 와류각도는 ANSI/HI 9.8의 설계기준인 5° 이하로 나타나 흐름의 안정성을 확인하였다.