• Title/Summary/Keyword: 소음 노출

Search Result 217, Processing Time 0.026 seconds

Research on the actual vibration exposure of workers engaging in vibration induced works (진동작업 종사 근로자의 진동노출 실태에 관한 연구)

  • Kim, Kab-Bae;Chung, Eun-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.178-185
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 949 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to $1.7{\sim}2.8m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were $7.1{\sim}10.8m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were $3.3{\sim}11.1m/s^2$. Workers using a impact wrench were exposed to $1.5{\sim}1.6m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplaces to control vibration was not much different from the past because there are no vibration exposure limit.

  • PDF

Assessment on the Actual Vibration Exposure of Workers Engaging in Vibration Induced Works (일부 진동작업 종사 근로자의 진동노출 수준 평가)

  • Kim, Kab-Bae;Chung, Eun-Kyo;You, Ki-Ho;Jang, Jae-Kil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.940-948
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 948 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to 1.7~2.8 $m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were 7.1~10.8 $m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were 3.3~11.1 $m/s^2$. Workers using a impact wrench were exposed to 1.5~1.6 $m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplace to control vibration was not much different from the past because there are no vibration exposure limit.

Comprehensive Analysis of Exposed Adverse Factors in Disaster Response Activities - Focused on Fire - (재난 대응 활동 시 노출가능 유해인자 종합분석 -화재 현장을 중심으로-)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.420-430
    • /
    • 2014
  • Firefighters performing disaster response activities such as Fire Suppression Rescue First Aid in fire are being exposed in various adverse factors, heat, smoke, toxic gases, emotional stress, biological toxic factors and physical overload by unnatural ergonomic posture required for firefighters. But so far, there is the study for this problem only separately. There is no study about comprehesive analysis of exposed adverse factors in fire-related disaster response activities and countermeasures. The purpose of this study is to contiribute to solving the health problems and prevention of accidents of firefighters by extracting hazardous agents in disaster such as fire and by proposing countermeasures. After analyzing circumstances such as fire-suppression, rescue first aid and life-environment, exposure factors of fire are derived and exposure status is suggested according to physical chemical biological psychological aspects. The countermeasure against the noise of the physical exposure factors are proposed. The countermeasures such as protective equipment and clean room in chemical factors, infection prevention education, vaccination and periodic check system in biological factors, PTSD alleviation booth and mentoring in psychological factors are proposed.

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

Remote work during the COVID-19 pandemic and perception of indoor environment: a focus on acoustic environment (코로나19 팬데믹 기간 재택근무 경험자의 실내환경 인식: 음환경을 중심으로)

  • Sang Hee Park;Hye-kyung Shin;Kyoung-woo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.627-636
    • /
    • 2023
  • Due to the COVID-19 pandemic, the global population has experienced drastic changes, one of which is the increase in remote work. Given the ongoing possibility of exposure to infectious diseases and various other circumstances, the expansion of remote work is anticipated. To enhance the efficiency of remote work and address its existing limitations, this study surveyed the perceptions of indoor environments among individuals who worked from home during the COVID-19 pandemic. The study examined how the characteristics of individuals influenced their perceptions of indoor environments. It was found that the number of occupants and rooms, size of the house, and noise sensitivity affected the perceptions of outdoor noise, neighbor noise, and indoor noise caused by cohabitants. The findings can be used as foundational data for designing multipurpose housing that can be utilized not only for residential purposes but also for work and educational settings in the future.

The Protective Effect of Orally Ingested Korean Red Ginseng on the Noise Induced Hearing Loss in Mice (마우스에서 고려 홍삼의 구강내 섭취를 통한 소음성 난청의 예방효과)

  • Ahn, Joong-Ho;Kim, Tae-Soo;Chung, Hana;Lee, Na-Young;Chung, Jong-Woo
    • Journal of Ginseng Research
    • /
    • v.33 no.2
    • /
    • pp.104-110
    • /
    • 2009
  • It is well known that the saponin of Korean red ginseng (KRG) has an anti-oxidant effect and could suppress the accumulation of lipid peroxidation. The aim of the present study was to observe the inhibitory effect of KRG on mice with noise-induced hearing loss, and to determine its optimal dose. BALB/c mice with a normal hearing level and normal Preyer's reflexes were used in the study. The mice in the permanent-threshold-shift (PTS) group were exposed to noise (120-dB SPL, white noise band) in a noise booth for 3 h a day, for three consecutive days. The mice in the experimental group were given heat-processed red-ginseng extract (50 mg/kg, 100 mg/kg, and 200 mg/kg), and those in the control group were given normal saline alone during their noise exposure. The mice in the temporary-threshold-shift (TTS) group were exposed to noise (120 dBSPL, white noise band) in a noise booth for 3 h. The mice in the experimental group were given heat-processed red-ginseng extract (50 mg/kg, 100 mg/kg, and 200 mg/kg), and those in the control group were given normal saline alone before their noise exposure. The hearing levels of the mice were measured through auditory brainstem response (ABR) immediately and I, 3, 5, 7, and 14 days after their noise exposure. Cochleae were removed from the mice 14 days after their noise exposure. lmmunochemical and immunofluorescent staining were performed to observe the expression of 8-oxoG in cochlea. In the PTS group, the hearing function of the mice in all the groups was not recovered after their noise exposure. In the TTS group, however, the hearing function of the mice in all the groups was recovered within 14 days. Reduced hearing impairment and early recovery were observed in the mice that were given 200 mg/kg KRG, and early recovery was observed in the mice that were given 100 mg/kg KRG The immunopositive staining of 8-oxoG was detected in the stria vascularis in the control group but was diminished in the mice that were given 200 mg/kg KRG The ingestion of more than 100 mg/kg KRG demonstrated a protection and recovery effect on the noiseinduced-TTS group. Since KRG has been reported to be a safe compound even up to hundreds of mg/kg, a higher concentration of it may effectively protect and recover TTS.

Evaluation of Human Exposure to Vibration on Domestic High-speed Train using ISO 2631-1 (ISO 2631-1을 이용한 국내 고속철도차량의 인체진동 노출량 평가)

  • Kim, Ji Man;Park, Jin Han;Ahn, Se Jin;Jeong, Weui Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.266-274
    • /
    • 2015
  • Vibration exposure of domestic high speed trains(KTX and ITX-saemaeulho) to passenger traveling on the Gyung-Bu line was measured to evaluate health effect which is based on ISO 2631-1. The vibration exposure was compared with the frequency weighted root mean square(r.m.s.) and vibration dose value(VDV) of the two trains’ vibration. It is concluded that vibration exposure of the two train during round trip of Busan-Seoul in single day is evaluated to be safe for the passenger’s health according to the health guidance caution defined on ISO 2631-1. Futhermore KTX’s vibration exposure is found to be significantly lower than ITX-saemaeulho thanks to lower vibration magnitude as well as shorter trip time.

Vibration Characteristics of a Nuclear Fuel Rod in Uniform Axial Flow (균일한 축방향 유동에 노출된 핵 연료봉의 진동특성 분석)

  • Jeon, Sang-Youn;Suh, Jung-Min;Kim, Kyu-Tae;Park, Nam-Gyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1115-1123
    • /
    • 2006
  • Nuclear fuel rods are exposed to axial flow in a reactor, and flow-induced-vibration due to the flow usually causes damage in the fuel rods. Thus a prior knowledge about dynamic behavior of a fuel rod exposed to the flow condition should be provided. This paper shows that dynamic characteristics of a nuclear fuel rod depend on axial flow velocity. Assuming small lateral displacement, the effects of uniform axial flow are investigated. The analytic results show that axial flow generally reduces fuel rod stiffness and raises its damping in normal condition. Also, the critical axial velocities which make the fuel rod behavior unstable were found. That is, solving generalized eigenvalue equation of the fuel rod dynamic system, the eigenvalues with positive real part are detected. Based on the simulation results, on the other hand, it turns out that the ordinary axial flow in nuclear reactors does not affect to stability of a nuclear fuel rod even in the conservative condition.

Response Characteristics of Aeroelastic Systems Using Robust Controller (강인한 제어기를 이용한 공탄성 시스템의 응답특성)

  • Na, Sungsoo;Jeong, In-Joo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.437-444
    • /
    • 2005
  • This paper presents a robust aeroelastic control methodology of a two dimensional flapped wing system exposed to an incompressible flow field. A robust controller is designed using a linear matrix inequality (LMI) approach for the multiobjective synthesis. The design objectives are to achieve a mix of $H_{\infty}$ performance and H₂ performance satisfying constraints on the closed loop pole locations in the presence of model uncertainties. Numerical examples are presented to demonstrate the effectiveness of LMI approach in damping out the aeroelastic response of 3-DOF flapped wing system.