• Title/Summary/Keyword: 소음의 감쇠

Search Result 537, Processing Time 0.021 seconds

Prediction of the Damage in the Structure with Damping Using the Modified Dynamic Characteristics (동특성 변화를 이용한 감쇠 구조물의 손상예측)

  • Lee, Jung Youn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1144-1151
    • /
    • 2012
  • A damage in structure alters its dynamic characteristics. The change is characterized by changes in the modal parameter, i.e., modal frequencies, modal damping value and mode shape associated with each modal frequency. Changes also occur in some of the structural parameters; namely, the mass, damping, stiffness matrices of the structure. In this paper, evaluation of changes in stiffness matrix of a structure is presented as a method not only for identifying the presence of the damage but also locating the damage. It is shown that changed stiffness matrix can be accurately estimated a sensitivity coefficient matrix derived from modifying mode shapes, First, with 4 story shear structure models, the effect of presence of damage in a structure on its stiffness matrix is studied. By using these analytical model, the effectiveness of using change of stiffness matrix in detecting and locating damages is demonstrated. To validate the predicted changing stiffness and its location, the obtained results are compared to the reanalysis result which shows good agreement.

A predictor-corrector algorithm of the generalized-$\alpha$ method for analysis of structural dynamics (동적해석을 위한 일반화된$\alpha$ 방범의 예측 수정자 알고리즘)

  • ;Hulbert, Gregory M.
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.207-213
    • /
    • 1995
  • A new predictor-corrector explicit time integration algorithm is presented for solving structural dynamics problems. The basis of the algorithm is the implicit generalized-.alpha. method recently developed by the authors. Like its implicit parent, the explicit generalized-$\alpha$ method is a one- parameter family of algorithms in which the parameter defines the high-frequency numerical dissipation. The algorithm can be utilized effectively for linear and nonlinear structural dynamics calculations is which numerical dissipation is needed to reduce spurious oscillations inherent in non-dissipative time integration methods used to solve wave propagation problems.

  • PDF

Experiment of a Liquid Damper Controlling Bi-directional Wind Responses of a Tall Building (초고층 건물의 양방향 풍응답 제어를 위한 액체댐퍼 실험)

  • Lee, Hye-Ri;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • This study deals with the design of a bi-directional damper using a tuned liquid damper(TLD) and a tuned liquid column damper(TLCD) for a SDOF building. Two dampers are usually needed to reduce wind-induced responses of tall buildings since they are along and across wind ones. The proposed damper has the advantage of controlling both responses with a single damper. The damper used in this study behaves as both a TLCD in a specific translational direction and a TLD in the other orthogonal direction. This paper presents experimental verification to confirm its control performance. First, shaking table test is carried out to investigate reducing responses by the damper. Control performance of the damper is expressed by the transfer function from shaking table accelerations to SDOF building ones. Testing results show that the damper reduced bi-directional responses of a SDOF building. Also, it reduced torsion responses.

Comparison of Damping Matrix Estimation Methods for Model Updating (모형개선을 위한 감쇠행렬 추정법의 비교)

  • Lee, Gun-Myung;Ju, Young-Ho;Park, Mun-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.923-930
    • /
    • 2010
  • Finite element models of dynamic systems can be updated in two stages. In the first stage, mass and stiffness matrices are updated neglecting damping, and in the second stage, damping matrices are estimated with the mass and stiffness matrices fixed. Three methods to estimate damping matrices for this purpose are proposed in this paper. The methods include one for proportional damping systems and two for non-proportional damping systems. Method 1 utilizes orthogonality of normal modes and estimates damping matrices using the modal parameters extracted from the measured responses. Method 2 estimates damping matrices from impedance matrices which are the inverse of FRF matrices. Method 3 estimates damping using the equation which relates a damping matrix to the difference between the analytical and measured FRFs. The characteristics of the three methods are investigated by applying them to simulated discrete system data and experimental cantilever beam data.

Equivalent Damping Ratio Based on Earthquake Characteristics of a SDOF Structure with an MR Damper (지진특성에 따른 MR감쇠기가 설치된 단자유도 구조물의 등가감쇠비)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.87-93
    • /
    • 2008
  • Seismic control performance of MR dampers, which have severe nonlinearity, varies with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally. response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

Effects of flow field on the performance of the concentric resonator (동심관형 공명기 내부의 유동장의 변화가 성능에 미치는 영향)

  • Lee, Seong-Hyun;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.715-718
    • /
    • 2002
  • 자동차 및 유체기계의 흡기계나 배기계에 사용되는 소음기의 음향성능은 전달손실로 기계성능은 배압으로 표현된다.유체가 흐르는 관 사이의 임피던스 부정합을 이용하는 반사형 소음기의 경우, 내부 유로에 천공을 주어 음향감쇠를 시키거나 유동을 안정시키는 경우가 많다.본 연구에서는 동심관형 공명기의 내부 관에 존재하는 천공의 분포 양상의 변화가 공명기 내부의 유동장에 미치는 영향을 살펴보고, 그 유동장의 변화에 따라서 소음기의 성능이 어떠한 영향을 받게 되는지를 고찰하였다.또한 유동장에 영향을 미치며, 소음기의 설계 인자 중 하나인 면적 확장비의 변화가 유동장 및 배압에 미치는 영향을 예측하였다.이로부터 유동의 흐름을 제어하여 소음기의 성능을 향상시키는 방법을 찾고자 한다.

  • PDF

Design and Performance Evaluation of Spring-viscous Damper for Torsional Vibration (스프링-점성형 비틀림 진동댐퍼 설계 및 성능 평가에 관한 연구)

  • Lee, D.H.;Chung, T.Y.;Kim, Y.C.;Kim, H.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1192-1198
    • /
    • 2011
  • Design routines of a torsional spring-viscous damper for a 1800 kW four cycle diesel engine-generator system are described. Modal techniques for system normalization and optimal equations for damper design are used to obtain proper design parameters of the damper. A prototype damper is manufactured according to the described design process and its two design parameters, stiffness and damping, are evaluated experimentally by torsional actuator test and free decay test. Experimentally obtained values of stiffness and damping coefficients showed good agreements with the designed values of the prototype damper.

Finite Element Vibration/Shock Analysis of Double Stage Elastic Mounting System with Viscoelastically Damped Foundation Structure (유한용소법을 이용한 점탄성 감쇠구조물이 포함된 2단 탄성마운트 시스템의 진동/충격응답 해석)

  • 정우진;류정수;배수룡;함일배
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.508-516
    • /
    • 2000
  • To study the possibility of F.E.M application to vibration and shock response of double stage elastic mounting system with complicated damped foundation structure like common-bed or raft in ships foundation structure model which has complicated damped sandwich cross-section is analyzed first. And then vibration responses experimental results and shock response of double stage elastic mounting system with complicated damped foundation structure like common-bed or raft in ships foundation structure model which adopts the above damped structure as intermediate foundation were compared. As a result it is found that F.E.M could be effectively used in analyzing the vibration and shock response of double and multi-stage elastic mounting system with complicated damped foundation structures.

  • PDF

A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System (감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구)

  • 안찬우;최석창;김동영
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF

Equivalent linearization of a Friction Damper and Brace System (마찰감쇠기-가새 시스템의 등가선형화 기법에 관한 연구)

  • Min, Kyung-Won;Park, Ji-Hun;Kim, Dae-Hyun;Kim, Hyung-Seop;Moon, Byoung-Wook;Kang, Sang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.750-753
    • /
    • 2005
  • An equivalent linearization technique based on Rayleigh peak distribution for friction damper and brace system (FDBS) under stochastic excitation is proposed. For verification, shaking table test of a small scale 3-story building model with the FDBS is conducted for various slip moment levels. Using experimental result, equivalent linearization of the FDBS is conducted based on Rayleigh peak distribution, which is compared with measured peak distribution. For comparative study, model updating technique is applied based on identified modal properties. Finally, complex modal analysis and time history analysis for the obtained equivalent linear systems are conducted and compared with experimental result

  • PDF