• Title/Summary/Keyword: 소음방지대책

Search Result 53, Processing Time 0.024 seconds

Noise Isolation Method at Construction Site (건설공사장 소음방지 대책)

  • Jung, Gab-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.940-948
    • /
    • 2000
  • Noise and vibration generated at construction sites become serious issues because of bigger construction projects and growing use of heavy equipment. Especially in downtown construction, noise and vibration easily exceed the legal standards that can suffer the most of surrounding residents. The number of complaints by the residents who are exposed to the noise increases as their consciousness grows. However, the Korean regulations for the construction noise and vibration only present the overall limits for target areas and times zones, and this make it difficult to take effective measures. Also in rural area, disputes between construction sites and residents arise, but the dispute resolution or taking measures are difficult because clear standards concerning cause-and-effect, estimation of effective levels, calculation of damages, and future precautions and examples lack. This paper describes legal standards regarding the noise and vibration and presents judging standards for the physical damages. This paper also introduces example public complaints that happened at Daewoo construction sites to describe the problems in the existing law and further to enable smooth construction progresses by emphasizing the seriousness of public complaints.

  • PDF

An experimental research on the heating characteristics and the elimination of noise in electric ondol for off-peak storage use (축열형 전기온돌의 난방특성과 진동소음 제거에 관한 실험적 연구)

  • 현경호;오명환;채성기
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.75-86
    • /
    • 1973
  • 본 연구에서는 전기온돌의 안방열손실을 감소시키고 축열효과를 향상시키기 위한 방법을 검토하였으며 전기온돌에서 발생하는 진동소음을 감살시킬 수 있는 대책을 제시하였다. 저육들은 6.6[m$^{2}$] 크기의 전기온돌 model을 이용하여 건물의 구조차이와 하향열단열층의 설치유무에 따른 보온특성의 차이를 기록분석하였으며 그 결과 열전도계수가 0.03[kcal/m.hr.deg. C]정도인 내열성 Styropol과 지석 Mortar로 구성된 하향열단열층을 전기온돌의 마닥에 설치할 경우 난방부하의 감소로 인하여 축열효율이 약 2배나 향상된다는 결론을 얻었다. 또한 전기온돌공사시에 발열선을 지지할 수 있는 대각선형 Spacer를 설치하고 발열선이 매설콘크리트가 완전히 양생된 이후에 전력을 인가하면 흔히 전기온돌에서 발생하는 120-960[Hz]의 가청진동소음을 방지할 수 있다는 사실을 실험적으로 확인하였다.

  • PDF

Low Noise Breaker (저소음 브레이커 개발)

  • 김정태;전오성;윤병옥;이영화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.213-216
    • /
    • 1995
  • 공사장의 건설기계 소음은 저주파 에너지를 많이 가지고 있기 때문에, 일단 소음이 발생되면 그 전파가 멀리까지 감쇄없이 진행하는 물리적 특징을 가지고 있으며 현실적으로 흡음재처리를 통한 소음방지효과는 저조한 실정이다. 특히, 선진국에서는 건설기계 등의 엄격한 소음 인증제도 실시로 인해 국내 일부 건설장비 생산제품이 외국에서 요구하는 소음규제치를 초과하기 때문에 저소음, 저진동 건설기계 설계 기술의 발전이 없으면, 향후 수출여건이 점차 어려워지고 있다. 이와같은 주변여건의 변화로 인해 건설기계를 생산하는 입체에서는 공사장 소음과 같은 저주파 에너지에 의해 지배 받는 소음문제를 효과적으로 저감시키기 위한 건설기계의 저소음, 저진동 설계의 필요성을 심각하게 인식하고 있는 실정이다. 건설기계중, 소음이 문제시되는 기계로는 지반정지공사, 기초공사, 콘크리트공사, 포장공사, 파괴 및 해체공사와 기타등 6가지가 있다. 이중에서 환경연구원의 연구결과에 따르면, 항타기, 브레이커 및 착암기가 높은 소음도를 나타내고 있다. 가장 높은 소음을 배출하고 있는 항타기는 기초 공사에 쓰이는 것으로써 지반 천공후 H빔을 싣는 디젤 항타기의 경우, 소음도가 107dBA를 보여주고 있다. 이 값은 기계로부터 7m 떨어진 거리에서 측정된 값이다. 또, 파괴 및 해제공사에 쓰이는 브레이커는 98dBA의 소음도를 보여주고 있다. 착암기는 작용원리에 따라 91-96dBA의 소음을 배출하고 있다. 본 연구에서는 건설기계중 소음이 높아 문제시 되고 있는 유압 브레이커의 저소음 설계기술개발에 관한 내용이다. 저소음 브레이커의 개발을 위해 소음에너지의 전달경로를 검토하고, 현실성있는 소음방지 대책을 제시하였다. 연구결과, 브레이커의 설계개량을 통해, 10dB의 소음저감효과를 볼 수 있어 만족스러운 결과를 도출할 수 있었다.타를 처리하기에는 부적절한 방법임이 널리 알려진 사실이다[3]. 최근에 Ben Mrad와 Fassois[4]는 신호에 잡음이 존재하여도 이를 잘 처리할 수 있는 확률적(stochastic) 방법을 개발하여 기존의 결정적 방법들과 그 결과를 비교하였다. 그러나, 개발된 방법은 응답 신호에 백색잡음(white noise)이 섞이는 특수한 경우에만 사용할 수 있게 만들어져서 이 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection

  • PDF

A Field Survey of Noise Associated with Subway Train Passage (지하철 연도변의 소음 조사)

  • Son Jung Gon
    • Explosives and Blasting
    • /
    • v.11 no.2
    • /
    • pp.60-68
    • /
    • 1993
  • The noise and vibration generated by the subway rolling stocks operated along the Seoul Subway Line No.1, 2, 3, and 4 lead to a controversy of pollution problem especially in residential areas. However, there is no data or guide to define the damage or provide adequate protection against such pollutions. The field measurements were made to characterize the noise attenuation due to distance, noise level distribution around the subway track of the aboveground and underground parts of each Line. The assessment criteria and methods are considered in addition to the practical available noise control methods. The noise level measured at Line No. 1 and 3 are less than 60 dB(A) with no pollution problem. Only a part of the aboveground section of Line No.2 and 4 indicates severe noise pollution. The effective boundary of these areas exposed to 70dB (A) noise are within 50m from the track centerline of No.2 line and 25m of No.4 line. The residents file a strong complaints whenever the noise level exceeds the 80dB (A) , and an occasional complaints between 70 to 80 dB(A). The distribution of high level noise of 80 dB(A) occurs within 25m from the track centerline of the overbridge, 12.5m of the short steel bridge, and about loom of the long steel bridge such as Dangsan Bridge. The intermediate noise level of 70 to 80 dB(A) is recorded within 50m from the overbridge, U-type retaining structure, and short steel structure, and 280m from the long steel bridge. The results presented in this paper can be used to understand the characteristics of the noise pollution along the Seoul Subway now In operation, and used as a guide to improve the existing noise pollution problems.

  • PDF

A Study on Dynamic Stiffness Criteria Decision of Structure (건물 용도에 따른 동강성 기준 결정에 관한 연구)

  • Ryu, Kuk-Hyun;Lee, Hong-Ki;Park, Hae-Dong;Baek, Jae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.352-355
    • /
    • 2006
  • 본 연구에서는 건축 구조물 용도에 따라 구조물의 직접적인 손상을 방지하기 위하여 규제하는 기준치, 인간의 감각 통하여 느껴지는 진동으로 안락한 주거 환경 또는 작업 환경을 유지하기 위한 규제치, 구조조물에 설치된 장비, 특히 반도체, 통신장비등과 같이 정밀장비의 경우 구조물에서 발생되는 진동으로부터 장비의 성능을 유지시켜주기 위한 기준 등을 확인하여 건물 용도에 최적의 진동 허용 규제치를 제안하며 기준에 따른 초기설계단계에서 최적저감대책을 수립하고자 함이다.

  • PDF

A Case Study on the Prediction of Underwater Sound by Measuring Ground Vibration (지반진동 측정을 통한 수중소음 예측 및 관리 적용사례)

  • Lim, Dae-Kyu;Cho, Kwang-Hyun;Jun, Yang-Bae
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.86-98
    • /
    • 2010
  • As the quality of life is being upgraded, the public complaints about noise and vibration from construction sites are growing. Despite the disputes over the blasting damage on aquatic lives in river, ocean, and aquarium near construction sites tend to increase, most of existing solutions or regulations on the damages caused by blasting are established for the damages on land. Although the estimated amount of damage is up to several millions of USD, there is no guideline for resolving the dispute related to the underwater vibration. This paper presents an example where the public grievance about the underwater noise was successfully resolved by elucidating the characteristics of underwater sound, deducing the correlations between ground vibration and underwater sound during blast, and predicting the underwater sound level during blasting from the ground vibration measured on the ground near an aquarium basin.

A Study on portable voice recording prevention device (휴대용 음성 녹음 방지 장치 연구)

  • Kim, Hee-Chul
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.209-215
    • /
    • 2021
  • This study is a system development for voice information protection equipment in major meetings and places requiring security. Security performance and stability were secured with information leakage prevention technology through generation of false noise and ultrasonic waves. The cutoff frequency band for blocking the leakage of voice information, which has strong straightness due to the nature of the radio wave to the recording prevention module, blocks the wideband frequency of 20~20,000Hz, and the deception jamming technology is applied to block the leakage of voice information, greatly improving the security. To solve this problem, we developed a system that blocks the recording of a portable smartphone using a battery, and made the installation of a separate device smaller and lighter so that customers do not recognize it. In addition, it is necessary to continuously study measures and countermeasures for efficiently using the output of the anti-recording speaker for long-distance recording prevention.

Vibration Isolation Method of Walking Space in the Multiplex Cinema (Multiplex 영화관의 보행면 진동방지 대책)

  • Lee, Sung-Ho;Jung, Gab-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.913-920
    • /
    • 2000
  • The hall and the projection room of the multiplex cinema being constructed on the sixth and seventh floors at Jeonpo-dong market, Pusan, is composed of structural beams and decks considering the structures self weight problem, and the following problems are expected: - Vibration and noise generated on the floors by moving audiences may annoy the audiences in the other hall - Vibration and noise generate on the floor of the nearby hall as the audiences walk through the alley near the projection room - Vibration and noise generate on the floor of the hall nearby the projection room as the film drops This study measured and reviewed the vibration amount of the seven representative transferring routes that were selected for the halls and the alley near the projection room. Based on the analysis, the model hall was constructed and the vibration in the hall was estimated after cutting the deck. Also, this study constructed the steel stairs and investigated the vibration transferring characteristics to decide whether to construct the steel stairs in the building. Finally, the results were evaluated by actually using the stairs and reviewed the appropriateness of the measurement.

  • PDF

Study on the Reduction Method of Magnetic Noise and Vibration in Home Electric Motors (가전기기용전동기의 전자소음과 진동의 방지대책에 관한 연구)

  • 황영문;조철제
    • 전기의세계
    • /
    • v.26 no.5
    • /
    • pp.74-82
    • /
    • 1977
  • This study is to present a method for reductin of noise and vibration of home electric motors coupled to the mechanical load causing relatively big amplitude of vibration. The noise and vibration factors have been analysed in the divisions such as the pattern related to the armature reaction, the pattern related to the circulating current by induction and the other patterns those are affected by a dditive magnetic field and have an effect on mechanical constants. From the systematic mutual relations between the patterns and daping effects, it is possible to derive the fundamental measure for reduction of noise and vibration. Vibration measurements and analysis were carried out in accordance with the planned experimentation and thre object model was chosen randomly from the production line in a factory where home electric machines were mass-produced. Based on the above-mentioned fundamental measure, suppression effects on noise and vibration have been analysed according to the number of slots, the amount of rotor skew and the way the stator winding connection was series or parallel.

  • PDF

기획특집 - T.A.B. 수행절차 및 수행 계획

  • An, Jeong-Ho
    • 월간 기계설비
    • /
    • s.232
    • /
    • pp.50-70
    • /
    • 2009
  • T.A.B란 공기조화설비에 대한 종합시험조정으로 시험, 조정 및 균형(Testing, Adjusting & Balancing)이라는 뜻이다. 이는 설계 목적에 부합되도록 모든 빌딩의 환경시스템을 검토하고, 조정하는 과정이다. 따라서 T.A.B기술은 공기 및 물이라는 유체의 흐름과 온 습도에 관련된 분야이기 때문에 시각적으로 그 성과를 알아보기 힘들고, T.A.B를 적용한 후 결과치를 정밀 분석해 판단할 수 있으며 T.A.B기술을 적용하지 않은 건물과 간접비교하는 방법으로 그 효과를 쉽게 알 수 있다. T.A.B기술을 적용할 경우 시공 중인 건물에 설계도서가 완료되기 전, 또는 장비의 구매발주 전에 T.A.B측면에서 모든 기술 도서를 면밀히 검토하게 된다. 그 중 일부에서 발견되는 문제점들 즉, 적정치 못한 용량 선정, 시스템 구성상 미비점, 불필요한 장비 선정, 누락 사항을 발견할 수 있다. 따라서 T.A.B 기술을 적용할 경우 향상된 품질의 시공이 가능해 준공 후 빈번히 대두되는 하자 문제가 현격히 줄게 되며 또한 운전경비 절감, 쾌적한 실내환경 조성, 장비수명 연장 등 효율적인 운전관리 효과를 얻을 수 있다. 우리나라 공기조화설비기술은 꾸준한 발전을 이루었고, 최근에는 도입 초기단계시 전혀 고려되지 않던 공조공간의 쾌적성 및 소음 방지 대책 등의 문제가 주요사항으로 부각되고 있다. 이에 따라 공조설비에 T.A.B실행의 표준화 정착과정에 있으며, 국내 학계 및 연구기관에서 공조설비에 대한 연구 및 T.A.B용역업체의 기술축적 등 T.A.B분야 발전을 위해 노력하고 있다. 본지는 T.A.B의 수행절차 및 수행계획, TAB 수행업체 등에 대해 알아본다.

  • PDF