• Title/Summary/Keyword: 소산계수

Search Result 122, Processing Time 0.024 seconds

Proposal of a New Experimental Method for Evaluating the Stability of Armor Blocks (소파블록의 안정성 평가에 대한 새로운 실험방법 제안)

  • Kim, Shinwoong;Lee, Seong-Dae;Lee, Kwang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.3
    • /
    • pp.131-138
    • /
    • 2021
  • The armor blocks are used to protect the body of the structure and dissipate wave energies, so it is crucial to evaluate the stability of the armor unit. The stability of armor blocks has been mainly evaluated through empirical coefficients called the stability coefficient obtained from hydraulic model experiments. In this study, a new type of single-layered armor block called K-Block was proposed, and a new experimental method based on the pull-out force was proposed to evaluate the stability of the armor unit, including the interlocking effects. The pull-out force test proposed in this study directly measures the force required to separate the armor unit from the armored layer on the slope by applying a tensile force in the vertical and horizontal directions to the installed armor unit. The proposed experimental method confirmed that the interlocking effects of the armor block could be quantitatively evaluated, and the high stability of the K-Block was verified.

Optical Properties of Sea Water in Sagami Bay, Japan (일본 상모만에서의 해수의 광학적 성질)

  • YANG Yong-Rhim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.2
    • /
    • pp.119-125
    • /
    • 1987
  • Optical properties of sea water were studied in the Sagami Bay, Japan, based on the data obtained from six oceanographic stations in June, 1985. The observation of surface irradiance and underwater irradiance of sea water for eight kind of wavelengths (378, 422, 481, 513, 570, 621, 653, 677 nm) of sun light was conducted using the underwater irradiameter $(Isigawa\;\#\;SR-8)$. The mean attenuation coefficient of the sea water was appeared to be 0.166 $(0.061\~0.644)$ and the attenuation coefficient of the sea water for wavelength appeared such as 0.121 for 378 nm, 0.105 for 422 nm, 0.097 for 481 nm, 0.099 for 513 nm, 0.138 for 570 nm, 0.253 for 621 nm, 0.258 for 653 nm, 0.253 for 677 nm. The transparency was 12.9 m $(7.2\~18m)$, water color was $(5\~10m)$ in the study area and the sun altitude was $70.79^{\circ}\;(57.44^{\circ}\~78.42^{\circ}C)$ The relationship between attenuation coefficient (K) ana transparency (D) was $K=2.87/D(1.06/D\~5.48/D)$. The rates of light penetration for eight kind of wavelenths (378, 422, 481, 513, 570, 621, 653, 677 nm) were computed with reference to the surface light intensity respectively, The mean rate of light penetration in proportion to depths were $77.93\%\;(52.52\~94.06\%)$ in 1 m layer, $35.46\%\;(4.00\~73.64\%)$ in 5m layer, $18.71\%\;(0.24\~54.23\%)$ in 10m layer and $7.00\%\;(0.007\~27.58\%)$in 20m layer. The rate of light penetration at the transparency layer with reference to the surface light intensity was shown as $13.02\%\;(0.42\~34.78\%)$.

  • PDF

Optical Properties of Sea Water in Tokyo Bay (동경만에서의 해수의 광학적 성질)

  • YANG Yong-Rhim;MORINAGA Tsutomu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.3
    • /
    • pp.234-240
    • /
    • 1986
  • Optical properties of sea vater were studied in Tokyo Bay, Japan, based on the data obtained from six oceanographic station in April, 1985. The observation of surface and underwater irradiances of sea water for eight kinds of wavelength (378, 422, 481, 513, 570, 621, 653, and 677 mm) of sun light was conducted using the underwater irradiameter (Isigawa ${\sharp}SR-8$). The mean attenuation coefficient of the sea water appeared to be 0.335($0.081{\sim}0.862$) and the attenuation coefficient of the sea water for each wavelength appeared as 0.268 for 378nm, 0.354 for 422nm, 0.274 for 481nm, 0.256 for 513nm, 0.284 for 570nm, 0.356 for 621nm, 0.425 for 653nm, and 0.464 for 677nm. The transparency was 5.0m ($2.5{\sim}6.5m$), water color was 10.2 ($8{\sim}14.0$) in the study area and the sun altitude was $53.62^{\circ}$ ($38.54^{\circ}{\sim}66.23^{\circ}$). The relationship between attenuation coefficient (K) and transparency (D) was K= 2.22/D ($1.30/D{\sim}3.54/D$). The rates of light penetration for eight kinds of wavelength (378, 422, 481, 513, 570, 621, 653, and 677 nm) were computed with reference to the surface light intensity each. The mean rates of light penetration in proportion to depths were $62.72\%$ ($42.23{\sim}78.43\%$) in 1 m layer, $11.91\%$ ($1.34{\sim}29.67\%$) in 5m layer, $2.64\%$ ($0.023{\sim}8.80\%$) in 10m layer, and $0.50\%$ ($0.02{\sim}3.99\%$) in 20 m layer. The rate of light penetration at the transparency layer with reference to the surface light intensity was shown as $12.51\%$ ($2.91{\sim}27.25\%$).

  • PDF

Prediction of Inelastic Force-Displacement Relationships of Reinforced Concrete Shear Wall Systems Based on Prescribed Ductilities (강성저하 실험식 및 연성계수를 이용한 철근콘크리트 전단벽 구조시스템의 비탄성 하중-변위 관계식 예측)

  • 홍원기
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.159-171
    • /
    • 1995
  • The parameters describing a complete hysteresis loop include pinch force, drift offset, effective stiffness, unloading and reloading trangential stiffness. Analytical equations proposed to quantify the nonlinear, inelastic behavior of reinforced shear walls can be used to predict these parameters as a function of axial load and drift ratio. For example, drift offset, effective stiffness, and first and second unloading and reloading tangential stiffness are calculated using equations obtained from test data for a desired drift ratio or ductility level. Pinch force can also be estimated for a given drift ratio and axial load. The effective virgin stiffness at the first yield and its post yield reduction can be estimated. The load deflection response of flexural reinforced concrete shear walls can now be estimated based on the effective wall stiffness that is a function of axial force and drift ratio.

  • PDF

피에조 콘 소산시험을 이용한 압밀계수 추정시 이론해의 선택 및 현장지반의 압밀도 평가

  • 이승래;김영상
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1998.04a
    • /
    • pp.37-46
    • /
    • 1998
  • Several researchers have developed a number of theoretical time factors to determine the coefficient of consolidation by biezocone excess pore water dissipation test in soft clay deposits. However, depending on the assumptions and analytical techniques, the estimated coefficient of consolidation could be in a considerably wide range even for a specific degree of consolidation. These solutions are obtained from an initial excess porewater pressure distribution which can be determined from. either the cavity expansion theory or the strain path method. The 야ssipation of the initial excess porelvater pressure has been usally simulated by means of linear-uncoupled consolidation analysis and then the dissipation curve is normalized by the initial excess porewater pressure for easy use. However. since there is no guidelines or rules on which method gives the best solution for obtaining the coefficient of consolidation from the dissipation curve, the final selection was only based on engineer's extrience and Judgements. Thus, such an arbitrary selection might be inappropriate for a specific site to characterize the consolidation behavior. In this paper, we reviewed various theoretical time factors and, based on this consideration, we mentioned needs for researches in selecting a specific solution that is compatible for Korean clays. Also we listed some source of errors that can be encountered in the procedure of dissipation analysis.

  • PDF

Estimation on the Power Spectral Densities of Daily Instantaneous Maximum Fluctuation Wind Velocity (변동풍속의 파워 스펙트럴 밀도에 관한 평가)

  • Oh, Jong Seop
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 2017
  • Wind turbulence data is required for engineering calculations of gust speeds, mean and fluctuating loading. Spectral densities are required as input data for methods used in assessing dynamic response. This study is concerned with the estimation of daily instantaneous maximum wind velocity in the meteorological major cities (selected each 6 points) during the yearly 1987-2016.12.1. The purpose of this paper is to present the power spectral densities of the daily instantaneous maximum wind velocity. In the processes of analysis, used observations data obtained at Korea Meteorological Adminstration(KMA), it is assumed as a random processes. From the analysis results, in the paper estimated power spectral densities function(Blunt model) shows a very closed with von Karman and Solari's spectrum models.

Experimental Study on Buckling Restrained Knee Bracing Systems Using Bolted Channel Sections (볼팅 고정 채널 형강 보강재를 이용한 비좌굴 Knee Bracing System의 내진성능에 대한 실험 연구)

  • Lee, Jin;Lee, Ki-Hak;Lee, Sung-Min;Shin, Ji-Wook;Kim, Young-Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.37-46
    • /
    • 2009
  • In this study, the seismic performance of the Buckling Restrained Knee Bracing (BRKB) system was evaluated through a pin-connected 1-bay 1-story frame. The BRKB system using a bolted channel section developed was composed of a steel plate as a load-resisting core member and two channel sections as a restrainment of the local and global buckling of the core plate. The main purpose of the BRKB system is to be used as an effective tool to re-strengthen/rehabilitate old low- and mid-rise RC frame buildings, which do not have enough seismic resistance to earthquake loadings. The main variables for the test specimens were the size of the core plates, stiffeners and the use of guide plates. The test results showed that the size of the core plate, which was the main element for the load-resisting member, was the most important parameter to achieve ductile behavior under tension as well as compression, until the maximum displacement exceed twice the design drift limit given by the AISC Seismic Provisions.

Instantaneous Monitoring of Pollen Distribution in the Atmosphere by Surface-based Lidar (지상 라이다를 이용한 대기중 꽃가루 분포 실시간 모니터링)

  • Noh, Young-Min;Mueller, Detlef;Lee, Kwon-Ho;Choi, Young-Jean;Kim, Kyu-Rang;Lee, Han-Lim;Choi, Tae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • The diurnal variation in pollen vertical distributions in the atmosphere was observed by a surface-based lidar remote sensing technique. Aerosol extinction coefficient and depolarization ratio at 532 nm were obtained from lidar measurements in spring ($4^{th}$ May - $2^{nd}$ June) 2009 at Gwangju Institute of Science & Technology (GIST) located in Gwangju, Korea ($35.15^{\circ}E$, $126.53^{\circ}N$). Unusual variations of depolarization ratio were observed for six days from $4^{th}$ to $9^{th}$ May. Depolarization ratios varied from 0.08 to 0.14 were detected at the low altitude in the morning. The altitude with those high depolarization ratios was increased up to 1.5 - 2.0 km at the time interval between 12:00 and 14:00 LT and then decreased. The temporal variations in high values of depolarization ratios from lidar measurements show good agreement in patterns with the sampled pollen concentrations measured using the Burkard trap sampler. This study demonstrates that the pollen distribution data obtained by lidar measurements can be a useful tool for investigating spatial and temporal characteristic of pollen particles.

Soil Improvement Effect of Waste Lime Sludge Using Prefabricated Vertical Drains (연직배수재를 이용한 폐석회 슬러지의 지반개량 효과)

  • Shin, Eun-Chul;Park, Jeong-Jun;Kim, Jong-In
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 2005
  • The disposal problem of waste lime which is a residual product of lime industry have caused a lots of arguments in the past few years. Further more, waste lime contains a high moisture content which causes the disposal of waste lime is a great difficulty. The purpose of this study is to investigate for the effective dewatering solutions by placing various prefabricated vertical drains. The moisture content and degree of consolidation, pore water pressure, changes of settlement, bearing capacity with various vertical drains in waste lime were analyzed. The laboratory test results indicate that PBD is 2 times higher than circular drain in coefficient of consolidation. Based on the laboratory test results, settlement, pore water pressure, and dewatering measurements are shown in similar tendency. It is considered that PBD can drain primitive pore water much efficiently. The picture of SEM shows that circular drain filter has a serious clogging problem in comparison with PBD. In conclusion, PBD holds a superiority in waste lime's ground improvement and dewatering pore water pressure from the waste lime sludge. Also, circular drain is desired for some modification in its filtering system.

  • PDF

Vibrational Properties of High Damping Polymer Concrete with Hybrid Damper (복합구조 댐퍼를 적용한 고 감쇠 폴리머 콘크리트의 진동 특성에 관한 연구)

  • Kim, Jeong-Jin;Choi, Kyung-Suk;We, Joon-Woo;Seok, Won-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.135-142
    • /
    • 2020
  • In the case of a concrete structure, vibration problems occur under various conditions because of its low damping performance. To solve this problem, a study on the high damping performance of the polymer concrete with hybrid damper has recently been increased. Since water is not used in polymer concrete, the curing time is short. Also, the physical properties and dynamic properties of polymer concrete are quite excellent. So polymer concrete is widely expected to be used for structural materials. The hybrid damper is the structural system that consists of steel balls and viscous fluid inside the pipe which is embedded in polymer concrete. It can reduce the structural vibrations through the energy dissipation mechanism of viscous fluid and steel balls. In this study, the physical and dynamic properties of polymer concrete with hybrid damper were compared with ordinary concrete. As a result, the elasticity coefficient and the strength of the polymer concrete with hybrid damper were so much excellent. In particular, the tensile strength was 6.5 to 10 times higher than ordinary concrete. The frequency response function and damping ratio were also compared. As a result, the dynamic Stiffness of the polymer concrete was 25% greater than that of ordinary concrete. The damping ratio of the polymer concrete was approximately 3 times higher than that of ordinary concrete. Although the dynamic stiffness of the hybrid damper showed similar tendency, the damping ratio was 3.5 times higher than that of ordinary concrete. Therefore, the polymer concrete with hybrid damper was superior to ordinary concrete.