• Title/Summary/Keyword: 소방통로

Search Result 35, Processing Time 0.025 seconds

The Convergence Study on the Effects of Social Captical on Subjective Happiness of Firefighters (소방공무원의 사회적 자본이 주관적 행복감에 미치는 영향에 관한 융합연구)

  • Choi, Hee Chul
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aimed to investigate the effect of firefighters' social capital on subjective happiness. This research was conducted from Jun 12 to Aug 25, 2017, and a descriptive analysis, t-test, hierarchical regression analysis was carried out based on the results of a survey with 351 firefighters in Gyeonggi-do to verify the research hypothesis. As a result, it was revealed that network(${\beta}=.315$, p<.001), trust(${\beta}=.293$, p<.01), cooperation(${\beta}=.225$, p<.01) and trust among other sub-variables of firefighters' social capital had significant effects on subjective happiness. Based on the results, this research suggested that various measures to strengthen social capital would be required in order to improve fire-fighters' happiness: efforts to increase trust within the organization, political support for vitalizing formal network as a communication channel among firefighters organizations, encouraging interest in the community and promoting informal network such as volunteer work, developing transparency in operating the organizational policy and system, etc.

A Study on the Electrical Properties of Parallel Arc (병렬아크의 전기적 특이점에 관한 연구)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.452-455
    • /
    • 2012
  • 전기배선 또는 코드가 가구 등의 무거운 물건에 깔리거나 진동이나 날카로운 모서리 등에 의해 피복이 손상되어 회로의 누설에 의한 경우 먼지 등 오염물질이 쌓여 습기를 포함하면 전기통로가 형성된다. 즉, 트래킹(tracking)현상과 부품의 열화 등에 의한 누설전류가 흘러 발생하는 전기적 조건의 변화 등이 있다. 또한 전기설비가 규격미달이나 노후된 경우, 전기설비를 변경할 경우, 혹은 전기설비가 잘못 사용되거나 기기와 맞지 않을 경우에 화재가 발생할 수 있다. 본 논문에서는 일반적으로 가정에서 사용되는 전원코드에서 충전부에 흡습되어 나타날 수 있는 병렬아크에 의해 전원코드가 열화되어 용융되는 특성을 고찰하였다.

  • PDF

A Study on the Quantitative Risk Analysis in Railway Tunnels (철도터널 정량적 위험도 분석에 관한 연구)

  • Park, Kyung-Hoon;Yoo, Yong-Ho;Yoo, Ji-Oh
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.502-505
    • /
    • 2011
  • 국내 철도터널 방재관련 법규에는 정량적 위험성 분석을 수행하여 주요한 방재시설의 설치 여부 및 규모를 결정하도록 규정하고 있으나 위험성 분석을 수행하기 위해 필요한 세부 기준에 대해서는 정해진 것이 없어 이에 대한 검토가 필요한 것으로 판단된다. 따라서 본 연구에서는 국내 철도터널의 정량적 위험도 평가 사례를 수집하고 이를 분석함으로서 철도터널 방재시설의 위험도 감소효과를 분석하고자 하였다. 정량적 위험도 평가사례분석 결과 Risk Index에 가장 크게 영향을 미치는 인자는 터널의 경사도로 분석되었으며, 방재설비 중 대피통로와 배연설비가 위험도 저감효과가 가장 높은 것으로 분석되었다.

  • PDF

The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor (스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향)

  • Jeon Heung-Kyun;Choi Young-Sang;Choo Hong-Lok;Jang Jun-Young
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.70-89
    • /
    • 2005
  • Fire scenarios in a space $20.0m\;\times\;4.0m$ floor and 3.0m high were simulated by using computational fluid dynamics program (FDS 4.0.3) to investigate the effect of the combined operation of both sprinkler and vent systems, which are installed for cooling and blocking smoke which propagates beneath the ceiling of a horizontal corridor, on the temperature and smoke density of it. It was shown that the combined operation both sprinkler and vent systems was more effective than each operation for cooling and blocking smoke, the number of operating sprinklers was two because of corner effect of wall, and over-installed sprinklers deteriorated the effect of cooling and blocking smoke. This study showed that the case of two sprinklers and vent flow rate $3.0m^3/s$ in fire scenario was the most effective for cooling and blocking smoke. It was confirmed that the smoke downdrag occurs in operating sprinkler system, and the more smoke droplets produced by increasing fire size, the greater smoke downdrag occurred.

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

Analysis of Safety Management Operations of Fire Risk Factors in Small-Scale Construction Sites (소규모 건설현장 화재 위험요인 안전관리 운영실태 분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.775-785
    • /
    • 2022
  • By analyzing the operation status of fire safety management of small construction site workers, deriving problems, and suggesting improvement measures, this study was conducted to present practical basic data for their efficient use in the future, and the following conclusions were drawn. First, it was analyzed that small construction site workers are elderly in the age group of construction workers, have short construction skills, most of the jobs are working in the construction industry, and the employment type is non-regular workers. Second, the fire safety management improvement plan of small construction site workers is systematized, fire safety manager is deployed to manage fire risk, fire escape routes and emergency warning facilities are provided to inform all workers at the construction site. In addition, measures to reduce industrial accidents are needed through realistic evacuation training, fire VR training, and interesting educational programs.

Experimental Study on Heat Flow According to the Wind Velocity in an Underground Life Space (지하생활공간 화재시 풍속에 따른 열유동 특성 연구)

  • Kim, Young-No;Suk, Chang-Mok;Kim, Wha-Jung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study analyzes heat flows and fire behavior through a reduced-scale model experiments about change of wind velocity in underground life space. When the wind velocity is increased the temperature rise time of the fire room was risen fast. And temperature of fire room was increased. And increase of wind velocity displayed maximum temperature at an opening of the fire room. Heat flows by fire spread increase size of smoke occurrence and flame, and displayed high temperature distribution in passageway than inside of neighborhood department promoting eddy flow spread as wind velocity increases. Finally, heat flows are decided by wind and wind velocity at fire of underground life space, and Wind velocity increases, temperature increase and decrease could confirm that is gone fast.

Numerical Analysis of Smoke Control for high-rise Building Considering with the Enthalpy Equation (Enthalpy Equation을 이용한 고층 건물의 제연해석)

  • Bae, Sung-Ryong;Ro, Kyoung-Chul;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.27-32
    • /
    • 2010
  • Recently, increases of population density due to the industrialization in the metropolitan cities has caused the high-density and integration of life environment. Then various high-rise buildings are constructed for accommodation. However, high-rise building fires can cause high casualties due to increases of smoke spread velocity through the vertical shaft. In this study, the new program based on the enthalpy conservation for analysis of energy transfer for smoke control system, CAU_ESCAP, was developed. CAU_ESCAP was validated by comparing with the result of ASCOS. The characteristic of smoke control was analysed by using CAU_ESCAP for high-rise building fires.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Analysis of Evacuation Route Selection Pattern of Occupant according to Installation Type of Exit Light and Opening/Closing Direction of Door (유도등 설치유형 및 피난구 출입문 개폐방향에 따른 재실자의 피난경로 선택패턴분석)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.28-34
    • /
    • 2019
  • The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.