• Title/Summary/Keyword: 소방시설

Search Result 504, Processing Time 0.024 seconds

A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility (보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2009
  • Recently, the number of child care facility and social demand for high quality child care service increase suddenly. Especially, social atmosphere about fire safety is more sensitive in Korea. The majority of the residents in a child care facility are composed of early childhood having difficulty to evacuate, and therefore the number of stories of a building and the appropriateness of a evacuation equipment play an important role in the evacuation safety. In this study, problems and improvements for the evacuation safety are dealt with the present conditions of child care facilities, the comparative analysis between domestic and foreign standards, the research on the actual condition of evacuation equipments, and so on. The study brings to a conclusion that it is necessary to systematize the regulations regarding fire safety, to connect fire-fighting facilities for design standards and operations of emergency preparation equipments, to improve the regulations for fire protection system such as the sprinkler system, and to restrict the facilities having fire hazards.

Improvement Method of Hazardous Materials Facilities Installation License of Manufacturer (위험물시설의 설치허가제도의 개선방안)

  • 이종영;이수경;김태환
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.21-35
    • /
    • 2001
  • By rearing private experts to design hazardous facilities, Safety property is obstained. So it is necessary to limit within the designer of hazardous materials facilities who has some degree skill. After permission progress about the inspection of the design ascertain whether it is safety property Mayor/Do governor permits within the laws and their qualification. Accordingly, Korea Fire Equipment Inspection Corporation be come specialization about the design, inspection of construction completion. A inquire purpose of Fire Service Act be considered fitness. Subject by which the Korea Fire Equipment Inspection Corporation is entrusted, subject by which the a non-probit corporation in The Civil Law be possible to entrusted in separate. In this case, because of the level of one's technique and facilities are important, to limit as a nonprobit corporation in The Civil Law give rise to trouble. Consequently; established a business corporation, which the level of one's technique and facilities, in accordance with The Commercial Law can assign inspection of construction completion. The contents of the Fire Services Act is caused by the historic growth of hazardous facilities's safety management. Because we decide on a course about completed inspection of hazardous substance, it is needed that adjust the task performed by a corporation of the exert skill and the duty performed by the task that a authorized corporation on the civil law or the commercial law To adjust the duty, the Fire Service Act, that is suitable to the purpose and principle, should constitute a measure of the duty. With the object of insure the safety of the hazardous substance, when the fire survice act establish a corporation of the expert skill. There is the will of lawmakers that need organization to have the power of the professional technology. The state excise the will that insure the safety of hazardous materials facilities on the basis of the professional technology and facilities, and construct to establish a corporation of the expert skill. Therefore as concentrate on the technology to need to insure the safety of the facilities of hazardous substance to be suitable on the purpose of laws and take responsibility and reports to a corporation of the expert skill. The task to be given to the state will be done.

  • PDF

A Study on the Understanding of Fire Service Officers to the Procurement Circumstances and the Alternatives for Procuring Fire Service Funds (소방재원의 조달여건 및 조달방안에 대한 소방공무원의 인식에 관한 연구)

  • Choi, Nag-Soon;An, Sang-Bong
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.87-97
    • /
    • 2007
  • This study is to investigate the problems of procurement circumstance of the current fire service funds and to suggest the alternatives for procuring the fire service funds for dealing with increasing demand on the fire service in the local autonomous era. The results are as the followings. First, most fire service officers see the procurement circumstances as premature stage and perceive the necessity of the improvement of this condition. In particular, the officers at the fire center recognize this problem as an urgent question than the officers at the front fire branches. In addition, as for the alternatives of the procurement of fire service funds, both groups prefer the long term plan to the short term plan, and show positive responses to the National Emergency Management Agency and central government as the entity to raise fire funds. As for the alternatives to improve financial system, both groups show the most positive responses on the way to increase the current common facilities tax. As for the specific procurement alternatives of fire funds, both groups agree the alternative to increase common facilities tax mostly, and to the next they agree the alternative to insecure fire funds by restructuring current financial system and by establishing fire service hospital and fire equipment maintenance center.

산림 내 산불 피해 시설 구분을 위한 연구

  • Park, Heung-Seok;Lee, Si-Yeong;Yun, Hwa-Yeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.179-179
    • /
    • 2013
  • 산림 내 시설은 산불 발생 시 접근성의 제한과 인접된 환경의 위험성으로 인해 큰 피해가 예상되는 시설이다. 또한 이러한 시설은 문화적 가치가 높은 문화재이거나, 사회적 파급효과가 큰 사회 간접 시설이 많아 이에 대한 효율적인 관리 방법의 제시가 필요하다. 본 연구에서는 이러한 산림내 시설의 정의와 위험성 구분을 위해, GIS를 이용하여 산림 내 시설의 지형적 환경을 분석하였다. 따라서, 수치 지형도에 의해 335개소의 산지 전용 가능 시설물을 추출한 뒤, 이를 통해 고도, 경사, 능선상의 위치를 분석하였다. 분석 결과, 문화재와 광산시설, 장례시설이 산불로부터 취약할 것으로 예상되며, 시설물의 분류 시설물 중 30%가 산림 내 시설물로 분석되었다. 보다 향후 추가적인 연구와 사례 검증을 통한 연구를 통한 지속적인 보강이 필요할 것으로 사료된다.

  • PDF

Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels (도로터널 방재시설의 소방관계법령 개선방안)

  • Seo, Hyo-Seon;Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • When a fire occurs in a road tunnel, it is likely to develop into a major disaster because of its sealed structural characteristics. Because of this, a range of disaster prevention facilities should be installed, and they should show their appropriate functions in fire prevention and response. In addition, the installation of essential disaster prevention facilities is missing due to the lack of considering an extension of continuous tunnels and soundproof tunnels. For these reasons, it was judged that an amendment to the law would be necessary. Therefore, this paper reviewed the changes in domestic laws related to the disaster prevention facilities of road tunnels, and the results of the study on the parts that need to be revised in the fire-related laws through a comparative analysis between laws are as follows. First, consecutive tunnels should consider the sum of the extensions of the individual tunnels and ensure that the soundproof tunnels are included in the category of tunnels in the law. In this way, the necessary disaster prevention facilities should be installed. Second, it is necessary to secure a legal justification for installing disaster prevention facilities in tunnels. Therefore, it is essential that water mist fire extinguishing system facilities, emergency broadcasting facilities, and leading lights, which are excluded from installation in tunnels, are specified in the Fire-related laws. Third, to specify in the law that air respirators must be provided in the tunnel is necessary from the viewpoint of the field response. Accordingly, it will make a great contribution to the fire-fighting activities and the life-saving efforts by fire-fighters.

A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores (대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구)

  • 홍성우;이영재
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.20-27
    • /
    • 2002
  • This study in focused on proposing the improvement plans for refuge and fire-fighting facilities in large shopping malls that are radically spreading. The main subjects are as follows. - The refuge measure for large shopping malls - Problems of installing the refuge facilities in stores and the solutions - Problems of installing the incendiary facilities in stores and the solutions - Problems of installing the indoor fire plug in stores and the solutions As result of the study, it has turned out that escape stairs which are set up according to the standard of size in the process of design plan, have to be decided for their amount, position, specification, etc, in consideration of the number of residents. It is also required to tighten a standard of installing a sprinkler instead of lightening the fire-fighting section in stores, considering obstacles due to facilities installed and procurement of the escape path. In addition, it needs to lighten a standard of installing the indoor fire plug, which is voluntarily set up at the store section incase of installing a sprinkler to make a practical fire-fighting facility available.

Basic Study for Improving the Fire Safety of Postpartum Care Centers (산후조리원의 화재안전성 향상을 위한 기초연구)

  • Lee, Jae-Won;Jin, Seung-Hyeon;Kim, Si-Kuk;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.138-146
    • /
    • 2019
  • The present article reports the results of a basic study for improving the fire safety of postpartum care centers. In the case of postnatal care center facilities, newborn babies and mothers reside 24 hours a day, and as they are located in high-rise and multi-use facilities, measures for fire safety are necessary, but there are no domestic manuals. This study examined the problems of fire safety through an analysis of fire cases of postpartum care facilities and related regulations, and conducted surveys on the fire safety consciousness of employees and mothers regarding postpartum care management. The fire safety consciousness of the mother was analyzed.

Automatic Fire Detector Spacing Calculation for Performance Based Design (성능위주설계를 위한 화재감지기배치의 공학적연구)

  • Park, Dong-Ha
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Placement method for fire detectors prescribed in current fire safety regulation is just about placing a prescribed number of detectors according to the areas. However, this regulation has no scientific basis and standards from foreign countries are just introduced and fire detectors are installed complying with them. There are two standards in designing fire protection systems; Prescriptive-Based Design that follows stipulated regulations like fire safety standards and Performance-Based Design based on engineering knowledge such as fire dynamics, structural dynamics, mechanics of materials, fluid mechanics, and thermo dynamics. Recently, Fire Protection System Construction Business Act was revised so that fire protection systems can be designed using Performance-Based Design method ('05. 8. 4), though the method has not activated until now. In addition, the enforcement decree defines the range for specific objects of fire protection to which Performance-Based Design is applied ('07, 1. 24). At the moment, by manufacturing simulator so that formulas can be introduced and calculated with software in order to install fire detector of automatic fire detection systems keeping optimized distance, comparing the results with the state of fire detector placed according to Performance-Based Design and analyzing them, this study was intended to settle Performance-Based Design method in the future.