• Title/Summary/Keyword: 소방설비

Search Result 595, Processing Time 0.025 seconds

A Study on a Method for Fire Suppression in a Central Area inside the Roof of a Wooden Cultural Property using a Gas Extinguishing Apparatus (가스소화설비를 이용한 목조 문화재 적심부 화재진압 방법에 관한 연구)

  • Kim, Hyunsung;Kim, Byung Sean;Cho, Woncheol;Lim, Yun Mook
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.65-71
    • /
    • 2010
  • This study was conducted to provide a method for fire suppression in a central area inside the roof of a wooden cultural property using a gas extinguishing apparatus, which is used as one of fire suppression methods with view to preventing valuable wooden properties inherited from ancestors from being destructed by fire. For a wooden property, it is very difficult to suppress fire when combustion spreads to a central area inside its roof, so it is impossible to put out a fire without destructing it. Such a fire fighting apparatus as a sprinkler, etc., installed in modern structures, is very effective, but the possibility of damaging a cultural property is highly probable after installment and operation, which leads to its low adaptability to a wooden property. Thus, the necessity of developing a fire suppress ion apparatus was raised to minimize the said problem and to obtain the desired results, and the need of making a plan on the installment was also raised based on the results of a test whose validity was proven. The central area inside a roof is a traditional - architectural style which is found in Korean wooden structures only, so it is impossible to discover similar cases in foreign countries. For this reason, this study was conducted to verify the effectiveness by developing a fixed fire suppression apparatus designed considering the speed and effectiveness in fire suppression. This study was sequentially carried out in the following steps. First, a frame for this study was made and the specific plan on a fire suppression method was established. Then, a fire suppression apparatus was installed. In the first step, the effectiveness for fire suppression was tested by installing valve open - punched - main water pores, and in the second step, the same effectiveness was tested by valve opened - punched - injection ports. For a wooden property similar to "Sungnyemun"(Gate of Exalted Ceremonies), its central area of the roof decides whether the fire suppression is successful or not, so the opinions on how to put out a fire were presented in this study, and thus the objective data to establish a method on fire suppression in a wooden structure(cultural property) was secured. Lastly, a scientific verification in the effectiveness for fire suppression measures was presented by installing a gas - fixed fire suppression apparatus.

  • PDF

A Study on the Large Experiments (ISO 13785-2) for Vertical Fire Behavior Analysis of Aluminum Composite Panels in General and Flame-retardant Material (일반재와 난연재 알루미늄복합패널의 수직화재 성상분석을 위한 실대형시험(ISO 13785-2)에 관한 연구)

  • Choi, Chui-Kyung;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.92-98
    • /
    • 2012
  • In this sturdy, large experimental (ISO 13785-2) was performed to analyze the building materials used in fire retardant materials for aluminum composite panel and in general properties. As a results, maximum temperature in the case of the general materials was measured in 210 seconds $1,021^{\circ}C$, the retardant materials was measured in 1,200 seconds early $1,190^{\circ}C$. The retardant material of aluminum composite panel, Fire behavior if the ignition is slow and the general materials in aluminum composite panel, fire ignition and combustion at the same time was growing rapidly. The general materials and flame-retardant material of aluminum composite panel was an obvious difference to the combustion ignition but after ignition combustion mode showed a similar pattern of the rapidly vertical spread of flame. The results of this study, in order to reduce the risk of aluminum composite panels for fire and the retardant materials used for ignition the slow should be actively encouraging. Also after the ignition, there is an urgent need to put out a fire in exterior materials for extinguishing facilities.

Analysis of Thermal Interrelation by Leakage Current in Open and Closed Statues (개방 및 밀폐상태에서의 누설 전류에 대한 열적 상관관계 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Choi, Seung-Ho;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.7-12
    • /
    • 2010
  • This paper is aimed the measurement and estimation the thermal interrelation based on leakage current. The leakage models are analyzed by parameters in open and closed (Panel) states and with wood dust and rainwater, charcoal powder in leakage current occurred point. The thermal characteristic of open state that leakage current is inputted in 90 mA is higher in charcoal powder ($105^{\circ}C$) than in wood dust and rainwater ($88.8^{\circ}C$). Charcoal powder that is inputted in 110 mA shows high thermal characteristic ($238.6^{\circ}C$) and the thermal ($238.6^{\circ}C$) is caused by material strain of electrical wire insulation and Panel. The closed state in 90 mA is higher in charcoal powder ($250.6^{\circ}C$) than in wood dust and rainwater ($90.8^{\circ}C$). The open and closed state appear thermal characteristics of two times in charcoal powder than in wood dust and rainwater. The thermal data that are open and close states are used electrical fire investigation and thermal characteristic for Leakage current.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

A Study on Fire Spread and Evacuation Risk of Conduit Combustion in Ceiling Hiding Place (천장 은폐장소 전선관 연소에 따른 화재확산 및 피난 위험도에 관한 연구)

  • Park, Kwang-Muk;Jeon, Jae-Kam;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.55-65
    • /
    • 2020
  • In this study, the ISO 5660 and ISO 5659 combustion tests were conducted with synthetic resin conduits (CD, VE) and metal conduit (ST) used for wiring work in electrical facilities, which can be installed in ceiling concealed places. Then, fire spreading and evacuation risks were analyzed based on the measured data. In the ISO 5660 test, CD of 120.5 MJ/㎡, VE of 81.9 MJ/㎡, and ST of 4.9 MJ/㎡ were measured. In the ISO 5659 test, the CD 1320, VE 731, and ST 102 were measured, and then the maximum smoke densities were measured for CD 605 s, VE 740 s, and ST 1,200 s. In terms of fire spreading and evacuation risk, the CD conduit, VE conduit, and ST conduit were in order. In the fire spreading risk analysis, total heat emission was calculated as 4,820 MJ/㎡, 4,267 MJ/㎡, and 196 MJ/㎡ for CD, VE, and ST, respectively. Evacuation risk analysis shows at transmittance of 89%, CD is 127 s, VE is 35 s, and ST is 969 s. At transmittance of 79%, representing almost invisible concentration, CD is 157 s and VE is 50 s. The CD and VE conduits had a high fire spreading and evacuation risks, while the ST conduit had little effect on fire spreading and evacuation risk.

A Study on Contents for Safety Training of the Thermal Power Plant to be Applied by Story Viewing (스토리 뷰잉(Story-viewing)을 적용한 화력발전분야 안전교육 콘텐츠 연구)

  • Kim, Yoo-sik;Min, Seol-hui;Seong, Yun-hak;Park, Yeong-jae
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.62-66
    • /
    • 2016
  • There have been happening small and big fires due to the various causes in the thermal power plants which are the high risk buildings with the high possibility of big sizes of accidents, so the people in the power plants distribute the workers "the site action manuals in thermal power plants" and try to minimize the rate of disasters like fires through the regular education and training. However, in the Five Thermal Power Plants in Korea, there are no the standard of "the site action manuals" and Furthermore, the present educational manuals are mostly the hard copies with poor readability. So the standardization of the manuals are definitely needed. Therefore, in this research, we proceed the standardization of the manuals for the five areas of the site action manual s in the thermal power plants which are oil fires, electric fires, building fires, facility fires and gas leaking reaction SOP to improve the reaction power on the disasters in the power plants which are the national significant infrastructures, thus by using the manual, we propose the safety education contents for the thermal power plants based on the visualization technology using story-viewing method to complement the hard copy type disaster manuals.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

A Study on Emergency Evacuation Route Planning and USN-Based Induction Activities of Correctional Facilities (교정시설의 비상시 피난경로계획 및 USN기반 대피유도활동에 관한 연구)

  • Park, Joo-Hyung;Park, Jong-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.39-46
    • /
    • 2011
  • In correctional facilities with majority of occupants in custody, the safe evacuation guide without getaway accidents should be very important due to complexity in escape paths. Fire causes are various in correctional facilities, for example, arson fire is a major cause in mental treatment facilities, however, old facilities or carelessness of flammable materials consist of fire causes in jail facilities. Both types of correctional facilities are the same in terms of many casualties from the fire cases. The thesis focus on escape paths and evacuation guide plans on the basis of analysis on fire cases and structural vulnerability, and then an electronic unlocking system is concededly installed for safe evacuation of occupants in custody without getaway accidents. Especially, the effect of the electronic unlocking system is going to be analyzed on the basis of RSET (required safe egress time) in order to realize for the occupants to evacuate safely to the front yard in case of emergency. In conclusion, if electronic security allowed system with USN (Ubiquitous Sensor Networks) technology should be installed in multi-storey correctional buildings, it is proposed that the occupants in custody might be a guided safely without getaway trials.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.