• Title/Summary/Keyword: 소구치 발거

Search Result 80, Processing Time 0.018 seconds

The effect of reinforcing methods on fracture strength of composite inlay bridge (강화재의 사용 방법이 복합 레진 인레이 브릿지의 파괴 강도에 미치는 영향)

  • Byun, Chang-Won;Park, Sang-Hyuk;Sang-Jin, Park;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.111-120
    • /
    • 2007
  • The purpose of this study is to evaluate the effects of surface treatment and composition of reinforcement material on fracture strength of fiber reinforced composite inlay bridges. The materials used for this study were I-beam, U-beam TESCERA ATL system and ONE STEP(Bisco, IL, USA). Two kinds of surface treatments were used; the silane and the sandblast. The specimens were divided into 11 groups through the composition of reinforcing materials and the surface treatments. On the dentiform, supposing the missing of Maxillary second pre-molar and indirect composite inlay bridge cavities on adjacent first pre-molar disto-occlusal cavity, first molar mesio-occlusal cavity was prepared with conventional high-speed inlay bur. The reinforcing materials were placed on the proximal box space and build up the composite inlay bridge consequently. After the curing, specimen was set on the testing die with ZPC. Flexural force was applied with universal testing machine (EZ-tester; Shimadzu, Japan). at a cross-head speed of 1 mm/min until initial crack occurred. The data was analyzed using one-way ANOVA/Scheffes post-hoc test at 95% significance level. Groups using I-beam showed the highest fracture strengths (p<0.05) and there were no significant differences between each surface treatment (p>0.05) Most of the specimens in groups that used reinforcing material showed delamination. 1. The use of I-beam represented highest fracture strengths (p<0.05) 2. In groups only using silane as a surface treatment showed highest fracture strength, but there were no significant differences between other surface treatments (p>0.05). 3. The reinforcing materials affect the fracture strength and pattern of composites inlay bridge. 4 The holes at the U-beam did not increase the fracture strength of composites inlay bridge.

INFLUENCE OF FLOWABLE COMPOSITE LINING THICKNESS ON CERVICAL MICROLEAKAGE OF PROXIMAL BOX (구치부 인접면 와동에서 유동성 복합레진 이장재의 두께가 치은 변연부 미세누출에 미치는 영향)

  • Cho, Yun-Jung;Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.259-267
    • /
    • 2008
  • This in vitro study aimed to investigate the influence of flowable composite lining with different thicknesses on the marginal quality. One hundred twenty cavities, each preparated with proximal boxtype( 3mm of bucco-lingual width, 2mm of mesio-distal depth and gingival margin of 1mm supra-CEJ) were randomly dived into four groups. group I : Tetric ceram filling alone(control group) group II: 0.5mm thickness Tetric flow + Tetric ceram filling group III: 1.5mm thickness Tetric flow + Tetric ceram filling group IV: 2.5mm thickness Tetric flow + Tetric ceram filling The followings are the results: 1. Group II showed significantly less microleakage compared to group I(control group)(p<0.05). 2. There was no statistically significant difference between group III, IV and group I(p>0.05). 3. Group II showed significantly less microleakage compared to group III, IV(p<0.05). 4. There was microleakage more or less in all group. It was concluded that 0.5mm flowable composite lining improved cavity adaptation and marginal sealing.

  • PDF

Construction of an ideal set-up model for lingual orthodontic treatment (설측 교정치료를 위한 셋업 모형 제작의 정밀도)

  • Bae, Gi-Sun;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.459-474
    • /
    • 2005
  • Making a precise and ideal set-up model is an essential part in the indirect bonding procedure for lingual orthodontic treatment. To evaluate the accuracy of the making a set-up model, 22 adult patients who received lingual orthodontic treatment with 4 bicuspid extractions were selected, and 3 sets of dental models (before, set-up, and after treatment) were measured using the set-up model gauge, an instrument for measuring the inclination and angulation of the clinical crowns on the dental model. Two sets of lateral cephalograms (before and after) from each patient were also evaluated. The mean difference between the before treatment model and the set-up model was $-3.93{\pm}6.98^{\circ}$ for the inclination and $1.87{\pm}5.79^{\circ}$ for the angulation. And the mean difference between the set-up model and the after treatment model was $-4.31{\pm}5.91^{\circ}$ labiolingually and $-2.16{\pm}3.27^{\circ}$ mesiodistally, The after treatment model differed from the before treatment model about $-8.24{\pm}5.39^{\circ}$ in inclination. There were no significant difference between the measured gauge that measured from the dental model using the set-up model gauge and the calculated gauge angle measured from the lateral cephalogram using constructed points and lines. Using the set-up model gauge, it is possible to evaluate the study model 3-dimensionally in relation with the patient's lateral cephalogram and establish whether the doctor's prescription or overcorrection is built in the set-up model precisely.

THE INFLUENCE OF $CARISOLV^{TM}$ ON SHEAR BOND STRENGTH OF COMPOSITE RESIN RESTORATIONS ($Carisolv^{TM}$의 사용이 복합레진 수복물의 전단결합강도에 미치는 영향)

  • Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.47-53
    • /
    • 2003
  • This study evaluated the influence of chemomechanical caries removal agent $Carisolv^{TM}$(MediTeam, Sweden) for composite resin adhesion to sound human permanent and primary dentin. The buccal/labial surfaces of 80 permanent molars and 80 primary incisors were used. Four types of adhesives and one composite resin were used; AQ Bond(Sun Medical, Japan), Clearfil SE Bond(Kuraray, Japan), Single Bond(3M, USA), Scotchbond Multi-Purpose(3M, USA) and Z100(3M, USA). One drop of $Carisolv^{TM}$(MediTeam, Sweden) was pretreated on the dentin for 0 second(control) and 60 seconds. The specimens were thermocycled for 1,000 times in baths kept 5 degrees C and 55 degrees C with a 30 seconds dwell time. Shear bond strengths were tested and the data was statistically analyzed using one-way ANOVA with subsequent post hoc Scheffe test at p<0.05. $Carisolv^{TM}$ treatment significantly decreased the shear bond strength. Shear bond strength of permanent dentin was significantly higher than that of primary dentin. Clearfil SE Bond treatment groups showed the highest shear bond strength and AQ Bond treatment groups showed the lowest shear bond strength.

  • PDF

DETECTION OF OCCLUSAL CARIES USING LASER FLUORESCENCE (레이저 형광법의 교합면 우식증 탐지 효과)

  • Kim, Chang-Gi;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.600-606
    • /
    • 2002
  • The purpose of this study was to evaluate the diagnostic validity of an incipient occlusal caries using argon laser fluorescence. Extracted human premolars and molars with enamel carious lesion of occlusal surface were assessed using visual examination, visual examination with probing, argon laser fluorescence and histologic depth of carious lesion. The results in each of all the three detection methods were compared to the assessment of histologic depth of carious lesion using polarized microscope. The results from the present study can be summarized as follows; 1. There was highly correlation between the histologic depth of occlusal caries and all three detection methods(P<0.01). 2. The reproducibility(kappa value) of the visual examination, visual examination with probing and argon laser fluorescence between the histologic depth of occlusal caries was 0.189, 0.128, 0.472. The highest correlation was seen between detection of occlusal caries by argon laser fluorescence and histologic scores by polarized microscope. The results from this study indicated that argon laser fluorescence considered to be accurate and reliable method in detecting occlusal caries.

  • PDF

Diagnosis of Early Dental Caries with Dye-Enhancing Quantitative Light-Induced Fluorescence (QLF) (정량 광유도 형광법(QLF)과 광활성제를 이용한 초기 치아우식증의 진단)

  • Kim, Mihee;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.218-225
    • /
    • 2015
  • This study used sodium fluorescein to improve imaging diagnostic ability by increasing the fluorescence difference between sound enamel and caries lesions. It also made it easier to discriminate between stain and caries lesions using quantitative light-induced fluorescence (QLF). Half of the specimen surface was covered with nail varnish as a control. Specimens were divided randomly in six decalcification groups and decalcified for different lengths of time. Then, ${\Delta}F$ was measured using QLF-D. After applying 0.075% sodium fluorescein, we measured ${\Delta}F$ again and compared it with the initial value. After cutting the central portion of the specimen, we measured the lesion depth using scanning electron microscopy. The lesion surfaces observed with QLF were darker than normal enamel, whereas they were lighter than normal enamel after applying fluorescein. Longer decalcification time was associated with greater fluorescent dye penetration. The ${\Delta}F$ measured after applying fluorescein was higher than the initial value (p < 0.05). Due to QLF measurement using fluorescein being more sensitive for diagnosing early decalcification, this approach will enable early diagnosis of dental caries before the cavity formation stage, allowing the treatment of early caries lesions. With QLF and sodium fluorescein, we can easily discriminate between stain and caries lesions.

EFFECTS OF ER:YAG LASER ABLATION ON THE DENTIN (Er:YAG 레이저를 이용한 치아삭제 효과)

  • Choi, Nam-Ki;Yang, Kyu-Ho;Park, Sang-Won;Kim, Ok-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.683-693
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of Er:YAG laser on cutting efficacy and its histologic findings. Dentin specimens of human premolars and molars were used and irradiated by Er:YAG laser with noncontact handpiece type delivery system under different treatment condition of irradiation time. Cavity pattern and volume were evaluated to determine the cutting efficacy and following results were obtained. 1. Cutting volume of sound dentin was getting larger with time immersed in water increase 2. With the condition of irradiation (150mJ, 10Hz, 30sec), surface irregularity was more increased in sound dentin comparing to carious dentin. For the light microscopic examination, dentinal tubules were opened and ash flecks and cracks were noted with inconsistence of dentinal tubules. 3. In case of 30 sec. irradiation in carious dentin, dark zone was limited to small focus whereas 1 min. irradiation, more wider, and cracks were noted in the perpendicular to direction of dentinal tubules. For the 2 min. irradiation, cavity was the widest and more cracks were found.

  • PDF

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

THE EXPRESSION OF OSTEONECTIN AND OSTEOCALCIN IN THE EXPERIMENTAL TOOTH MOVEMENT IN RAT (백서의 실험적 치아이동시 osteonectin 및 osteocalcin의 발현)

  • Bae, Sung-Real;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.699-716
    • /
    • 1998
  • This study was designed to evaluate the expression of non-collagenous protein in periodontal tissue during the experimental movement of rat incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for osteonectin and osteocalcin. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats) and 6 experimental groups(24 rats) where 75g of force was applied from helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. And the tissues of a control group and experimental groups were studied immunohistochemically and histologically. The results were as follows : 1. Until 28 days after force application, periodontal fibers had been strectched on tension side and compressed in pressure side of all the experimental groups, and the arrangement of periodontal fibers had not been recovered yet. 2. The expression of osteonectin in control group was rare in dentin, cementum and osteocyte, and was mild in odontoblasts and matrix of alveolar bone. 3. The expression of osteocalcin in control group was negative in gingiva, osteoblasts, osteocyte and cementum, and was rare in predentin, capillaries in pulp and periodontal ligament and the matrix of alveolar bone. 4. There was no difference in the expression of osteocalcin or osteonectin in dentin, cementum, pulp, odontoblasts, between of control and of experimental groups. 5. The expression of osteonectin in intermaxillary suture got the peak in 7-day and was declined after 14-day. The expression of osteocalcin remained in a same degree since it became mild in 14-day. 6. The expression of osteonectin in pressure side of periodontal ligament of experimental group was rare, which was similar to control group. But in tension side, it was increased until 14-day aftrer which it was declined. 7. The expression of osteocalcin in periodntal ligament was rare in 12-hour to 14-day, but became severe in 28-day, which was greater in tension side than in pressure side, and in the periodontal fiber next to alveolar bone than to tooth surface. 8. The expression of osteocalcin in alveolar bone was rare until 14-day in pressure side, but became moderate in 28-day. The expression of osteonectin was increased from 7-day by time dependency, which was greater in tension side than in pressure side.

  • PDF

The effects of salivary contamination on tensile bond strength of resin modified glass ionomer cements in bonding brackets (브라켓 접착시 타액 오염이 레진 강화형 글래스 아이오노머 시멘트의 인장 접착 강도에 미치는 영향)

  • Lee, Kyoung-A;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.83-89
    • /
    • 2000
  • The purposes of this study were to evaluate clinical applicability of resin modified glass ionomer cements and to determine the effect of salivary contamination on the tensile bond strength. Fourty extracted human permanent premolars were prepared lot bonding and standard edgewise brackets were bonded with Ortho-One, Fuji Ortho LC, Vitremer and Advance. Fourty extracted human permanent premolars were contaminated with saliva, dried and bonded with same materials above. The tensile bond strength was tested by Instron testing device aster storage in normal saline at ,$37^{\circ}C$ for 24 hours from bonding. The results were as follows : 1. The tensile bond strength of Ortho-One group was $7.68\pm1.76$, Advance group was $7.87\pm2.80$, Fuji Ortho LC group was $4.99\pm2.53$, Vitremer group was $2.80\pm0.88$ MPa. The tensile bond strength in contaminated condition of Ortho-One group was $4.12\pm1.67$, Advance group was $5.37\pm0.68$, Fuji Ortho LC group was $4.41\pm1.61$, Vitremer group was $2.60\pm1.10$ Mpa. 2. Salivary contamination did not affect the tensile bond strength when compared with the uncontaminated enamel group in Fuji Ortho LC and Vitremer (p>0.05) and there was great significant difference in the tensile bond strength of Ortho-One and Advance. 3. Advance, Ortho-One and Fuji Ortho LC seemed to have clinically a proper bond strength.

  • PDF