• Title/Summary/Keyword: 소각로

Search Result 1,148, Processing Time 0.034 seconds

A Study on Distribution of Soil Microarthropods in Pinus rigida Plantations following Strip-Cutting (대상벌채(帶狀伐採)한 리기다소나무 조림지(造林地)의 토양미소절지동물(土壤微小節肢動物) 분포(分布)에 관(關)한 연구(硏究))

  • Oh, Kwang-In;Cho, Hi-Doo;An, Ki-Wan;Jang, Seog-Ki;Chung, Jin-Chul;Kim, Choon-Sik
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.257-265
    • /
    • 2001
  • This study was carried out to investigate composition and distribution of the soil microarthropods in Pinus rigida plantations following strip-cutting from May 1998 to April 1999. The results of this study were as follows; 1. The individuals of soil microarthropods found during the research periods were 181, 904 and were identified into 21 orders in 7 classes. The classes were Arachnida, Insecta, Malacostra, Pauropoda, Diplopoda, Chilopoda and Symphyla. 2. The population density of the soil microarthropods was 82,962 individuals at the control area, 62,688 individuals at the reserve area and 36,254 individuals at the cutting area. The microarthropods in the control area were 2 times higher than those in the cutting area. 3. Although the major dominant taxa, Acari and Collembola, decreased in densities at the cutting area, the density reduction in Acari was higher than that in Collembola. This resulted in the increase of Collembola in terms of the relative abundance at the cutting area. 4. Among the total soil microarthropods, Arachnida was 59.74%, followed by Insecta of 39.82%. Such two groups comprise 99.56% of soil microarthropods. 5. According to the relative population density, Acari was 99.18% in Arachnida and 59.25% in the total and Collembola 93.99% in Insecta and 37.42% in the total. Therefore, individuals of Acari and Collembola was 96.67% of the total individuals. And the next abundant groups were Hymenoptera (0.95%), Diptera (0.64%) and Pseudoscorpiones (0.39%). 6. The population density of the soil microarthropods fluctuated seasonally, showing the bimodal pattern, being high in fall and spring. The highest density occurred in November and the lowest in July.

  • PDF

An analysis of the Domestic Interior Materials as the Ecological Design Aspects (친환경측면에서 본 국내 실내건축자재의 현황 조사 및 분석)

  • Chun Jin-Hie;Kim Jung-Ah
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.133-144
    • /
    • 2006
  • According to the latest report by the Customer Protection Board, those who moved into newly constructed buildings are complaining about unidentified pains, asking for more careful selection of constructive materials for prevention of such potential problems. It is internationally recognized today that ecological materials can serve a significant factor for users' health, environmental protection and better industrial competitiveness. This study examined eco-design aspects of each interior material through web site search, in order to help customers learn about and capitalize on eco materials in a proper manner. As a result, 1. It turned out that the domestic industry are giving an impetus to releasing new eco items focusing on lower VOCs emission or addition of functional components as part of the marketing strategy. However, it is recommended that company understand significance of life cycle, and produce eco-concept materials. 2. The reliable standard for choosing the domestic material is EL, HB, GR marks. It is desirable to enhance recycling technologies and expand the sustainable consumption. customer class, since many recycled items are not developed. 3. The sourcing is a vulnerable part in terms of the concept of being environment-friendly material. Therefore, many manufacturers should design the easy knock-down products and produce the good items using recycled materials instead of new raw materials. Also solutions for making the energy from burning material should be studied. 4. The guidebook or manual with correct information about eco-materials is required to promote production and consumption with sustainable concept. 5. Many manufacturers are emphasizing ecological materials for customers, but some of them intended to disrupt customers' proper selection by promoting even unverified items to be environment-friendly.

  • PDF

Analysis of Forest Fires during Chosun Dynasty through Historical Literature Survey (역사문헌 고찰을 통한 조선시대 산불특성 분석)

  • Kim, Dong-Hyun;Kang, Young-Ho;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.8-21
    • /
    • 2011
  • This study surveyed historical records on outbreak and features of forest fires during Chosun Dynasty's 518 years in being and analyzed the Annals of the Chosun Dynasty; The Diaries of the Royal Secretariat, archives from Records of the Border Defense Council, The Compilation of Ministry Proposals, Posthumous Records of King Cholchong etc. Forest fires were most prevalent and extreme during King Hyunjong (14 cases) and King Sunjo (13 cases) due to strong wind, and the biggest-ever forest fire broke out in the fourth year of King Soonjo (1804) in the east coast of Korea in Kangwon province. The fire had resulted in 61 fatalities and 2,600 destroyed houses. Forest fire in the east coast of Korea, Kangwon province, in the $13^{th}$ year of King Hyeonjong (1672) is recorded to have caused the highest number of deaths, 65people. The most frequent cause of forest fires during Chosun Dynasty was unidentified (42 cases), followed by accidental fire (10 cases), arson or lightning (3 cases), fire during hunting (2 cases), play with fire by children, destruction of patty fields and dry fields by fire and house fire (1 case respectively). By region, 56 % of forest fires erupted in the east coast (39 cases) and this was followed by the west sea (9 cases), Seoul and central region (8 cases) and the southern part of Korea (7 cases). By season, spring was found to be most vulnerable to forest fire as it accounted for 73 % of the total amounting to 46 cases. Behind were summer (11 cases), winter (6 cases) and autumn (0 case). Specifically, most forest fire broke out on April and May, which is the same as today. Archives and literature indicate that the person who involved in forest fire by accidental as well as arson had to be punished by banishment, expulsion from government office and public hanging. Also, officials in charge of the region that suffered forest fire were subject to reprimand. In conclusion, risk and gravity of forest fires were evident during the Chosun Dynasty as specified in historical archives and share many similarities with today's forest fires in terms of the duration and regional patterns.

Regional Analysis of Forest Eire Occurrence Factors in Kangwon Province (강원도 지역 산불발생인자의 지역별 유형화)

  • 이시영;한상열;안상현;오정수;조명희;김명수
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.3 no.3
    • /
    • pp.135-142
    • /
    • 2001
  • This study attempts to categorizes the factors of forest fire occurrences based on regional meteorologic data and general forest no characteristics of 18 cities and guns in Kangwon province. lo accomplish this goal, some statistical analyses such as analysis of variance, correspondence analysis and multidimensional scaling were adopted. To reveal the forest fires pattern of study region, a categorization process was conducted by employing the quantification approach which modified and quantified the metric-data of fire occurrence dates. Also, The fire occurrence similarity was compared by using multidimensional scaling for each study region. The major results are summarized as follows: It was found that the meteorological factors emerged as different to each region are average and maximum temperature, minimum dew point temperature and average and maximum wind speed. In the result of correspondence analysis representing relationships between fire causes and study regions, Kangrung is caused by arsonist, Chulwon, Hwachen and Yanggu caused by military factor, Sokcho and Chunchen caused by the debris burning, and Samchuk caused by general man-caused fires, respectively. Finally, the forest fire occurrence pattern of this study regions were divided into five areas such as, group I including Samchuk, Kangryung, Chunchen, Wonju, Hongchen and Hhoingsung, group II including Donghae, Taebaek, Yangyang and Pyongchang, group III including Jungsun, Chulwon and Whachen, group Ⅵ including Gosung, Injae and Yanggu, and group V including Shokcho and Youngwol.

  • PDF

A Study on the Maneuverabilities of the Training ship M.S. A-RA (실습선 아라호(M.S. A-RA)의 조종성능에 관한 연구)

  • 안영화;박명호;최환문;정용진
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.275-284
    • /
    • 2001
  • The for this study, turning circle tests and maneuvering indices were conducted to study and evaluate the maneuverabilities of the fishery training ship M.S. A-RA(G/T : 990tons). The results obtained were summarized as follows : 1. The advances of the starboard and port of the turning circle were measured based on the dumb card test method were 198m, 192m, the size of tactical diameters of them were 194m, 188m, respectively. 2. The advances at the starboard and port of the turning circles were measured according to the DGPS positioning obtained 196m, 194m, the size of tactical diameters of them were 194m, 190m, respectively. 3. The results were compared which came from the sizes of turning circle measured up with the dumb card test method during the trial test and from the size of turning circle measured according to the DGPS positioning. The advance of the turning circle measured at the time of the starboard turning according to the DGPS positioning was 1m longer than that of the trial test. And it was 21m shorter at the time of the port turning. 4. The rudder was steered at $35^{\circ}$ of rudder angle each starboard and port while the ship M.S. A-RA was advancing at full speed of 13 k't. The velocity of the ship was reduced to 7.8 k't at $180^{\circ}$ of turning angle and 6.0 k't at $360^{\circ}$ of turning angle and mean values of turning angular velocity of the port and starboard were $2.4^{\circ}$/sec and $2.3^{\circ}$/sec, respectively. 5. The Z test at each $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ of rudder angle was carried out to have the maneuvering indices K and T measured. K for the each rudder angle were 1.24, 1.45, and 1.65 while T for the each rudder angle were 0.33, 0.20, and 0.14. That is, K at the Z test at $30^{\circ}$ was greater than at the Z test of $10^{\circ}$ and $20^{\circ}$ while T at the $30^{\circ}$ Z test was less than at the Z test of $10^{\circ}$ and 20.

  • PDF

Development and Economic Effect of Integrated Optimum Operation System using Wide Area Energy (광역에너지이용 통합 최적화 운전 시스템 개발 및 경제적 효과)

  • Lee, Hoon;Kim, Lae-Hyun;Chang, Won-Seok
    • Journal of Energy Engineering
    • /
    • v.18 no.4
    • /
    • pp.221-229
    • /
    • 2009
  • This study develops the optimized operation program which enables effective and economic operation between individual and connected branch offices by analyzing the current status and influential indicators of district heating companies' capital branch offices. Accordingly, the study examines the efficiency of optimized operation program. In doing so, this study has diagnosed and analyzed various factors, such as boilers, pumps, and relevant tags (temperature, pressure, fuel amount) through investigation of individual branch offices, and finally succeeded in developing wide-ranging data base by factor covering one-year time period. Additionally, after running the optimized operation program, different branch offices, optimum preference has turned out "incinerator receiving heat from KEPCO>CHP >PLBs>PLBw." Meantime, except the connected offices, there has been no big difference between actual and optimum operation program in branch offices. Meanwhile, the integrated optimum operation program has made it possible the most optimal result only via the connecting supply and demand heat without changing received Heat from KEPCO which is the same as total productive heat. The result has showed that the reduction percentage per day is 2.45~6.80%, and the reduction cost per day is 22,727~60,077 thousand won given the randomly selected sample days. In particular, winter time shows the highest demand with the largest reduction cost whereas summer time illustrates the lowest demand with the smallest reduction cost. Given this result, reduction cost per year compared to actual heat production cost for one year theoretically would be 84 hundred million won. Also, the economic effect showed that the reduction cost percentage per year is more than 2.74% on heat production cost per year for all capital branch offices.

A Case Study on the Estimation of the Resource Recovery Potentials by Landfill Mining (매립지 정비에 의한 순환이용 가능량 산정 사례 연구)

  • Yi, Sora;Lee, Woo Jin;Rhee, YoungJoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.5-12
    • /
    • 2018
  • As many local governments have faced increasing conflicts on landfill use and the time of end use, it is difficult to provide an alternative landfill or conclude a consensus of lifespan extension for the existing landfill site. Therefore, the purpose of this study is to contribute improving of the landfill capacity by calculating the resource recovery potentials of landfilled waste previously and in the future by landfill mining. For this, rate of volume increase, weight ratio, and apparent density were adopted as major parameters and their values were calculated through previous cases. The rate of volume increase was calculated to 1.42 by averaging previous cases of three areas. The average weight ratio of soil matter was 45.6% by calculating for the three areas. For the combustible waste and incombustible waste, statistical data can be used. The apparent densities were divided by combustible waste, incombustible waste, and soil matter using an average of two areas value, i.e., $0.35ton/m^3$, $1.40ton/m^3$ and $1.58ton/m^3$. We analyzed the resource recovery potential of Cheongju landfill by using the estimated parameters. The additional landfill capacity was 45% of the existing landfill capacity by recovering landfilled waste by landfill mining. In addition, it is analyzed that the lifespan is extended to 20 years, if the combustible waste of new inputting waste is sorted and combusted for energy recovery and incineration ash, incombustible waste, and soil matter are only reclaimed into the existing Cheongju landfill. It is expected that the methodology and parameters of this study will be used as basic data when resource recovery potential is analyzed for another case study of landfill mining.

Development of VOCs Treatment Technology using High Efficiency Hybrid System with Multi-Scrone (멀티 선회류식 세정장치를 이용한 고효율 하이브리드 VOCs 습식처리 SYSTEM 개발)

  • Lim, Seong-Il;Kim, Nor-Jung;Kim, Sun-Mi;Lee, Seong-Hun;Kim, Sun-Uk;Chang, Won-Seok;Park, Dae-Won;Kim, Lae-Hyun;Kim, Jae-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.491-498
    • /
    • 2009
  • We studied to develop high-efficiency removal system of odor and VOCs(Volatile Organic Compounds) from environmental infrastructure facilities and oil refineries, painting facilities and so on. It can replace RTO and RCO. We tried an removal experiment for VOCs (toluene, xylene, benzene, MEK(methyl ethyl ketone), ethanol, formalin etc. and odor compounds (hydrogen sulfide, etc.). In process, as pre-treatment we used the scrubber with vortex flow (Multi-scrone) to remove the hydrophilic VOCs and as post-treatment, used fibrous bio-filter to remove the hydrophobic VOCs. This hybrid system remove with high efficiency both the hydrophilic VOCs and hydrophobic VOCs. And we tried to make this system to be compact. In experiment using Multi-scrone, contact time is 2~3 seconds and absorption scrubbing water is diaphragm-type electrolysis water. hydrophilic VOCs like ethanol and relatively hydrophilic odor compounds like hydrogen sulfide is excellent, these substances has been removed almost completely, respectively 95~99%, 93~97%. And for MEK, formalin also Showed a high removal efficiency, respectively 78~90%, 72~85%. But in experiment using Multi-scrone, the hydrophobic VOCs like BTX showed a low removal efficiency, respectively 16~22%, 12~18%, 8~16%. In hydrophobic VOCs, toluene removal experiment using fibrous bio-filter, early efficiency was low but after 10days, adaptation period showed high efficiency 85~95%. but in the mixed phase, toluene and MEK efficiency reduced 5~10%. this show microorganism treat first MEK easy to remove. The removal efficiency for MEK using the fibrous biofilter was stable, 80~92%. This hybrid system is also high economical efficiency for RTO. This system reduce more than 50% the cost of equipment and maintenance. As a result, we expect this technology is in the limelight as high efficiency treatment of VOCs in mid-low price.

Characteristic Assessment of Heavy Metals in Dusts Collected by the Air Filtration System at Subway Stations in Daegu, Korea (대구지역 지하철역사 공기여과필터 포집먼지에 함유된 중금속성분의 특성평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Shin, Dong-Chan;Kwak, Jin-Hee;Lee, Myoung-Sook;Yoon, Ho-Suk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Samples of subway dust were collected by the air filter system of 30 subway stations on Daegu subway line 1 in January 2008. Samples were sieved below 100 ${\mu}m$, and 14 elements were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic sources were significantly affected by indoor dusts than outdoor dusts. Results of pollution indices of heavy metals indicated that indoor dusts were more contaminated with heavy metal ions than outdoor dusts. The correlation analysis among trace elements indicated that components were much correlated in the order of natural sources-anthropogenic sources, anthropogenic sources-anthropogenic sources, natural sources-natural sources in both indoor and outdoor dusts. Trace element components of outdoor dusts were largely correlated than those of indoor dusts. In addition, indoor dusts were significantly affected by outdoor dusts rather than depth from the surface or the average daily number of subway passengers.

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.