• Title/Summary/Keyword: 셀

Search Result 5,378, Processing Time 0.035 seconds

A New Variable Degeneration Resistor for Digitally Programmable CMOS VGA (디지털 방식의 이득조절 기능을 갖는 CMOS VGA를 위한 새로운 가변 축퇴 저항)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.43-55
    • /
    • 2003
  • A degenerated differential pair has been widely used as a standard topology for digitally programmable CMOS VGAs. A variable degeneration resistor has been implemented using a resistor string or R-2R ladder with MOSFET switches. However, in the VGAs using these conventional methods, low-voltage and high-speed operation is very hard to achieve due to the dc voltage drop over the degeneration resistor. To overcome the problem a new variable degeneration resistor is proposed where the dc voltage drop is almost removed. The proposed gain control scheme makes it easy to implement a low-voltage and high-speed VGA. This paper describes the problems existed in conventional methods, the principle and advantages of the proposed scheme, and their performance comparison in detail. A CMOS VGA cell is designed using the proposed degeneration resistor. The 3dB bandwidths are greater than 650㎒ and the gain errors are less than 0.3dB in a gain control range from -12dB to +12dB in 6dB steps. It consumes 3.1㎃ from a 2.5V supply voltage.

  • PDF

Effects of Selenium and Zinc on the Toxicity of Cadmium in Rat (백서에서 셀레늄 및 아연이 카드뮴 독성에 미치는 영향)

  • 강영미;이용욱
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.1
    • /
    • pp.29-43
    • /
    • 1990
  • The purpose of this study is to investigate the vairous change in the toxicity of cadmium by the simultaneous administration of selenium and zinc, which have been reported to change -the toxicity of cadmium through the interaction with cadmium, to rat. For the experiment, 42 rats of Sprague-Dawley strain were used. The experimental groups were divided into 6 groups: a control group, a cadmium (100ppm) alone treatment group, a cadmium (100ppm) and zinc (100ppm) combined treatment group, and three cadmium (100ppm), zinc (100ppm) and selenium (1, 4, and 8ppm) combined treatment groups. The rats were allocated seven to each group and observed for seven weeks. The results of experiment are as follows: 1. The food consumptions of each group were reduced, compared with a control group, especially, in a cadmium and zinc combined treatment group and a cadmium $\cdot$ zinc and selenium(1ppm) combined treatment group to the significant level compared with a control group (p < 0.05). The water consumptions of each group were reduced to the very significant level compared with a control group (p < 0.01). The feed efficiencies of each group were lower than a control group, and among them the highest group was cadmium $\cdot$ zinc and selenium (8ppm) combined treatment group as 90% of a control group. 2. In all groups, the weight gains were highest in the second week and the total weight gains were reduced to the very significant level compared with a control group (p < 0.01). 3. In all groups, the relative weights of liver were reduced, compared with a control group, especially, a cadmium alone treatment group was reduced to the significant level (p < 0.05). The relative weight of kidney was high to the significant level in a cadmium alone treatment group (p < 0.05) compared with a control group. In all groups, the relative weights of testis were reduced, compared with a control group, but the levels were not significant. 4. The accumulation of cadmium was highest in the kidney and the order of height was in liver, testis and blood, respectively. In all groups, the amount of cadmium accumulation was high to the very significant level compared with a control group (p < 0.01). In liver, the amount of acdmium accumulation in. a cadmium alone treatment group was high to the significant level compared with a cadmium $\cdot$ zinc and selenium (8ppm) combined treatment group (p < 0.05), and in kidney, the amount of cadmium accumulation in a cadmium alone tretment group was high to the very significant level compared with the cadmium $\cdot$ zinc and selenium (4, 8ppm) combined treatment groups (p < 0.01). However, in testis, among the treatment groups the level was not significant and in blood, a cadmium alone treatment group was low to the significant level compared with the cadmium $\cdot$ zinc and selenium (4, 8ppm) combined treatment groups (p < 0.05). 5. According to the histopathological finding on the testis, some of the seminiferous tubules of a group treated with cadmium alone showed severe necrosis and atrophy. But the testis of cadmium $\cdot$ zinc and selenium (8ppm) combined treatment group was similar to that of a control group. From the results of this study, it can be concluded that the repeated simultaneous oral administration of large doses of selenium with the cadmium produces the partial amelioration of cadmium toxicity, whereas zinc does not.

  • PDF

An Arrangement Method of Voice and Sound Feedback According to the Operation : For Interaction of Domestic Appliance (조작 방식에 따른 음성과 소리 피드백의 할당 방법 가전제품과의 상호작용을 중심으로)

  • Hong, Eun-ji;Hwang, Hae-jeong;Kang, Youn-ah
    • Journal of the HCI Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.15-22
    • /
    • 2016
  • The ways to interact with digital appliances are becoming more diverse. Users can control appliances using a remote control and a touch-screen, and appliances can send users feedback through various ways such as sound, voice, and visual signals. However, there is little research on how to define which output method to use for providing feedback according to the user' input method. In this study, we designed an experimental study that seeks to identify how to appropriately match the output method - voice and sound - based on the user input - voice and button. We made four types of interaction with two kinds input methods and two kinds of output methods. For the four interaction types, we compared the usability, perceived satisfaction, preference and suitability. Results reveals that the output method affects the ease of use and perceived satisfaction of the input method. The voice input method with sound feedback was evaluated more satisfying than with the voice feedback. However, the keying input method with voice feedback was evaluated more satisfying than with sound feedback. The keying input method was more dependent on the output method than the voice input method. We also found that the feedback method of appliances determines the perceived appropriateness of the interaction.

A Study on the Correlation between the Volume of Indoor Space and the Measured Concentration of Indoor Radon (실내 체적과 라돈 농도와의 상관관계 연구)

  • Kang, Sung-A;Han, Dong-Hyun;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.97-104
    • /
    • 2007
  • The corelation between the indoor volume and the measured radon concentration has been analyzed by comparing the radon concentration and the indoor volume of apartment rooms in Jeonju City. We also measured the annual exposure dose based on the variation in indoor radon concentration over time. To do this, we took 8 larger rooms and 8 smaller rooms of apartment, respectively, as a sample. The average volume of the larger rooms and that of the smaller rooms were $31.59\;m^3$ and $16.82\;m^3$, respectively. The average radon concentration of the larger rooms and that of the smaller rooms turned out to be $71.73\;Bq/m^3$ and $108.51\;Eq/m^3$, respectively. indicating that indoor volume is in inverse proportion to the radon concentration, i.e., the bigger the ratio of the surface area/volume, the higher the indoor radon concentration. From the measurement of the variation in indoor radon concentration over time fur a single day, the average intraday radon concentration variation was found to be about $46.8\;Bq/m^3$. The highest level of concentration ($114.5\;Bq/m^3$) was measured between 8 and 10 AM and the lowest level of concentration ($67.7\;Bq/m^3$) between 2 and 4 PM. The annual exposure dose turned out to be in the range of 0.3 mSv/yr to 2.16 mSv/yr, showing that the dose in some apartments exceeded 1.3 mSv/yr, the numerical value presented by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR).

Real-Time Hierarchical Techniques for Rendering of Translucent Materials and Screen-Space Interpolation (반투명 재질의 렌더링과 화면 보간을 위한 실시간 계층화 알고리즘)

  • Ki, Hyun-Woo;Oh, Kyoung-Su
    • Journal of Korea Game Society
    • /
    • v.7 no.1
    • /
    • pp.31-42
    • /
    • 2007
  • In the natural world, most materials such as skin, marble and cloth are translucent. Their appearance is smooth and soft compared with metals or mirrors. In this paper, we propose a new GPU based hierarchical rendering technique for translucent materials, based on the dipole diffusion approximation, at interactive rates. Information of incident light, position, normal, and irradiance, on the surfaces are stored into 2D textures by rendering from a primary light view. Huge numbers of pixel photons are clustered into quad-tree image pyramids. Each pixel, we select clusters (sets of photons), and then we approximate multiple subsurface scattering term with the clusters. We also introduce a novel hierarchical screen-space interpolation technique by exploiting spatial coherence with early-z culling on the GPU. We also build image pyramids of the screen using mipmap and pixel shader. Each pixel of the pyramids is stores position, normal and spatial similarity of children pixels. If a pixel's the similarity is high, we render the pixel and interpolate the pixel to multiple pixels. Result images show that our method can interactively render deformable translucent objects by approximating hundreds of thousand photons with only hundreds clusters without any preprocessing. We use an image-space approach for entire process on the GPU, thus our method is less dependent to scene complexity.

  • PDF

Vane Shear Test on Nakdong River Sand (베인 전단시험기를 이용한 낙동강모래의 마찰각에 관한 연구)

  • Park, Sung-Sik;Zhou, An;Kim, Dong-Rak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.463-470
    • /
    • 2016
  • A vane shear test (VST) is a simple testing method for determining an undrained shear strength of cohesive soils by minimizing soil disturbance. In this study, the VST was used to determine a shear strength of sand. Dry Nakdong River sand was prepared for loose and dense conditions in a cell and then pressurized with 25, 50, 75 or 100 kPa from the surface of sand. A vane (5 cm in diameter and 10 cm in height) was rotated and a torque was measured within sand. When a torque moment by vane and friction resistance moment by sand is assumed to be equalized, a friction angle can be obtained. When a vane rotates within clay, a uniform undrained shear strength is assumed to be acting on cylindrical failure surface. On the other hand, when it is applied for sand, the failure shape can be assumed to be an octagonal or square column. The relationship between measured torque and resistant force along assumed failure shapes due to friction of sand was derived and the internal friction angle of sand was determined for loose and dense conditions. For the same soil condition, a series of direct shear test was carried out and compared with VST result. The friction angle from VST was between 24-42 degrees for loose sand and 33-53 degrees for dense sand. This is similar to those of direct shear tests.

Investigation of Properties of Structural Foam with Different Conformation and via Thermal Aging Condition (구조용 폼의 조성 및 열 노화에 따른 변형특성 관찰)

  • Choe, Jin-Yeong;Kwon, Il-Jun;Park, Sung-Min;Kwon, Dong-Jun
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.122-127
    • /
    • 2018
  • Sandwich composites of carbon fiber reinforced plastic(CFRP) and polymer foam will be used to automobile and aerospace industry according to increasing importance of light weight. In this study, mechanical and heat resistance properties of sandwich composites were compared with type of polymer foam (polyethylene terephthalate(PET), polyvinylchloride(PVC), epoxy and polyurethane). All types of polymer foams were degraded to 30, 60, 120, 180 minutes in $180^{\circ}C$. After heat degradation, the polymer foams were observed using optical microscope and compressive test was performed using universal testing machine(UTM). Epoxy foam had the highest compressive property to 2.6 MPa and after thermal degradation, the mechanical property and structure of foam were less changed than others. Epoxy foam had better mechanical properties than other polymer foams under high temperature. Because the epoxy foam was post cured under high temperature. As the results, Epoxy foam was optimal materials to apply to structures that thermal energy was loaded constantly.

Variation in Characteristics of Elastic Waves in Frozen Soils According to Degree of Saturation (포화도에 따른 동결토의 탄성파 특성 변화)

  • Park, Jung-Hee;Kang, Min-Gu;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1063-1075
    • /
    • 2013
  • The strength of frozen soils is one of the significant design parameters for the construction in frozen ground. The properties of frozen soils should be investigated to understand the strength of frozen soils. The objective of this study is to figure out the characteristics of elastic waves in frozen soils, which reflect the constituent and physical structure of frozen soils in order to provide fundamental information of those according to the degree of saturation. Freezing cell is manufactured to freeze specimens, which are prepared with the degree of saturation of 10%, 40%, and 100%. Piezo disk elements are used as the compressional wave transducers and Bender elements are used as the shear wave transducers. While the temperature of specimens changes from $20^{\circ}C$ to $-10^{\circ}C$, the velocities, resonant frequencies and amplitudes of the compressional and shear waves are investigated based on the elastic wave signatures. Experimental results reveal that the elastic wave velocities increase as the degree of saturation increases. The variation of resonant frequencies coincide with that of elastic wave velocities. A marked discrepancy in amplitudes of compressional and shear waves are observed at the temperature of $0^{\circ}C$. This study renders the basic information of elastic waves in frozen soils according the degree of saturation.

Study on Equivalent Circuit and Bandwidth of Short Wavelength Thin-film Transmission Line Employing ML/CPW composite structure for Miniaturization of wireless Communication System on RFIC (실리콘 RFIC 상에서 무선 통신 시스템의 소형화를 위한 마이크로스트립/코프레너 복합구조를 가지는 박막필름 전송선로의 등가회로 및 대역폭에 관한 연구)

  • Son, Ki-Jun;Jeong, Jang-Hyeon;Kim, Dong-Il;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • In this paper, we study the RF characteristics of the short wavelength thin-film transmission line employing microstrip line (ML)/coplanar waveguide (CPW) composite structure on silicon substrate for application to RFIC (radio frequency integrated circuit). The thin-film transmission line employing ML/CPW composite structure showed a wavelength shorter than conventional transmission lines. Concretely, at 10 GHz, the wavelength of the transmission line employing ML/CPW composite structure was 6.26 mm, which was 60.5 % of the conventional coplanar waveguide. We also extracted the bandwidth characteristic of the transmission line employing ML/CPW composite structure using equivalent circuit analysis. The S parameter of the equivalent circuit showed a good agreement with measured result. According to the bandwidth extraction result, the cut-off frequency of thin-film transmission line employing ML/CPW composite structure was 377 GHz. Above results indicate that the transmission line employing ML/CPW composite structure can be effectively used for application to broadband and compact RFIC.

A study on the mechanical performance of impregnated polymer foam in cargo leakage of LNG carrier (LNG운반선의 화물 누출 시 함침된 고분자 폼의 기계적 성능에 관한 연구)

  • Park, Gi-Beom;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.345-352
    • /
    • 2017
  • In this study, the effect of cryogenic liquefied natural gas leakage and loading on liquefied natural gas cargo hold is investigated to observe the performance of the polymer foam material that comprises the cryogenic insulation of the cargo hold. The primary barriers of liquefied natural gas carrier that are in contact with the liquefied natural gas will leak if damage is accumulated, owing to fluid impact loads or liquefied natural gas loading / unloading over a long period. The leakage of the cryogenic fluid affects the interior of the polymer foam, which is a porous closed cell structure, and causes a change in behavior with respect to the working load. In this study, mechanical properties of polyisocyanurate foam specimen, which is a polymer material used as insulation, are evaluated. The performance of the specimens, owing to the cold brittleness and the impregnation effects of the cryogenic fluids, are quantitatively compared and analyzed.