• Title/Summary/Keyword: 세팔로

Search Result 9, Processing Time 0.028 seconds

Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography (치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가)

  • Jeong, Cheonsoo;Kim, Jiyoung
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.433-438
    • /
    • 2015
  • To evaluate the radiation exposure level based on radiation workers' locations in dental radiography, the radiation dose rate in the radiographic room, lead glass, and operation system was measured. To that end, various devices were used, such as a Standard(Max-GLS, Shinhung), a panorama (PCH-2500, Vatech), a cephalometric radiography (PCH-2500), and a cone beam CT (PHT-30LFO, Vatech), as well as a PM1405 equipment as a radiation meter. Radiography conditions were set the same as the factors used in the clinical setting. As the result, the cone beam CT turned out the highest with 98 uSv and the standard showed the lowest level with 0.4 uSv/h. The panorama was measured to be higher than the Cephalo due to its different focus mode. On the lead glass surface and in the operation stand, the oral radiography device, panoramic, and Cephalo all were measured below the recording level. However, the cone beam CT was measured to have the leakage dose. Thus, radiation involved workers should be equipped with appropriate protection tools and reduce radiography time as much as possible. In addition, the structure of the radiation chamber should be also designed efficiently. Dental radiography has continued to grow in recent years, so it is necessary take appropriate protection measures for patients and radiation workers.

Adsorption of Cephalomannine onto Sylopute: Isotherm, Kinetic and Thermodynamic Characteristics (실로퓨트의 세팔로마닌 흡착: 등온흡착식 및 속도론적·열역학적 특성)

  • Kim, Hyunsik;Kim, Jin-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.219-224
    • /
    • 2019
  • In this study, the adsorption characteristics of cephalomannine on commercial adsorbent Sylopute were investigated using different parameters such as adsorption temperature, time, and initial cephalomannine concentration for the efficient separation of Taxus chinensis-derived cephalomannine by adsorption process. The Temkin isotherm model showed good fit to the equilibrium adsorption data. The adsorption capacity decreased with increasing temperature and the adsorption of cephalomannine onto Sylopute was physical in nature. Adsorption kinetic data fitted well with pseudo-second-order kinetic mode. According to the intraparticle diffusion model, film diffusion and intraparticle diffusion did not play a key role in the entire adsorption process. The process of cephalomannine adsorption onto Sylopute was exothermic and spontaneous. In addition, the isosteric heat of adsorption was constant even with variation in surface loading indicating homogeneous surface coverage.

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.

Synthesis and ${\beta}-Lactamase$ Inhibitory Activity of 7-Exomethylene Cephalosporanates (7-엑소메칠렌 세팔로스포라네이트 유도체의 합성과 $\beta$- 락타메이즈 억제작용)

  • 이종민;최수항;이현수;임채욱;임철부
    • YAKHAK HOEJI
    • /
    • v.43 no.6
    • /
    • pp.782-788
    • /
    • 1999
  • 7-Oxocephalosporanate 1 was treated with phosphonium salts 2~4 by Wittig reaction to afford 7-exomethylene cephalosporanates 5~7. They were oxidized to sulfones 8~10 with mCPBA. Deprotecton of benzhydryl 7-exomethylene cephalosporanate with $AlCl_3$ and NaHCO_3$ gave sodium salts of 7-exomethylene cephalosporanates 11~16. The ${\beta}-lactamase$ inhibitory activity of synthesized compounds 11~16 were compared with sulbactam, tazobactam and clavulanic acid against Type I, II, III, IV and TEM-2 $\beta$-lactamase in vitro. Compound 15 showed more potent activity than sulbactam and clavulanic acid against Type III, IV ${\beta}-lactamase$ enzyme.

  • PDF

Application of Universal Scaled Reduced Temperature Parameter to the Three-Arm Star Polystyrene (세팔 별모양 폴리스타이렌 사슬의 팽창에 대한 만능 환산 온도 파라미터의 적용)

  • ;;Ling Yun
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.255-264
    • /
    • 2003
  • Various chain sizes 3-arm star polystyrenes (PS, $M_{w}$=2.80$\times$10$^{5}$ , 2.49$\times$10$^{6}$ g/mol) in t-decalin solution were measured at the temperature range of 20~7$0^{\circ}C$ by means of viscometry and laser light scattering. In order to show universality in the expansion factor of 3-arm star polymer, it was expected that (N/ $R_{G,Br,o}$$^{2}$)$^{3}$2/$\tau$/$\tau$$_{C}$ would be used as an universal parameter, where $R_{G,Br,o}$ was the unperturbed radius of gyration of star PS. However, much better universality had been observed when (N/ $R_{G,Br,o}$$^{2}$)$^{3}$2/$\tau$/$\tau$$_{C}$ parameter of the linear PS was used even for the 3-arm star PS. It could be explained if branching effect had been already taken into account in the part of $\tau$/$\tau$$_{C}$(=[(Τ-Θ$_{Tc}$ )/Θ$_{Tc}$ ]/[(Θ$_{Tc}$$_{c}$)/ $T_{c}$]). Here N and Θ$_{Tc}$ stand for the number of monomer unit in a single polymer chain and a kind of theta temperature as the critical solution temperature $T_{c}$ of the infinite molecular weight, respectively.ely.y.ely.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

The causative organisms of pediatric empyema in Korea (소아 농흉 원인균에 대한 다기관 연구(1999. 9-2004. 8))

  • Yum, Hye-yung;Kim, Woo Kyung;Kim, Jin Tak;Kim, Hyun Hee;Rha, Yeong Ho;Park, Yong Min;Sohn, Myung Hyun;Ahn, Kang Mo;Lee, Soo Young;Hong, Su Jong;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.1
    • /
    • pp.33-39
    • /
    • 2007
  • Purpose : In spite of medical advances, empyema is a serious complication of pneumonia in children. Vaccination practices and antibiotic prescribing practices promote the change of clinical manifestations of empyema and causative organisms. So we made a nationwide clinical observation of 122 cases of empyema in children from 32 hospitals during the 5 year period from September 1999 to August 2004. Methods : Demographic data, and clinical information on the course and management of empyema patients were collected retrospectively from medical records in secondary and tertiary hospitals in Korea. Results : One hundred twenty two patients were enrolled from 35 hospitals. The most frequent age group was 1-3 years, accounting for 48 percent of all cases. The male to female sex ratio was 1.2:1. The main symptoms were cough, fever, respiratory difficulty, lethargy and chest pain in order of frequency. Hematologic findings on admission revealed decreased hemoglobin levels ($10.4{\pm}1.6g/dL$) and increased leukocyte counts ($16,234.3{\pm}10,601.8/{\mu}L$). Pleural fluid obtained from patients showed high leukocyte counts ($30,365.8{\pm}64,073.0/{\mu}L$), high protein levels ($522.3{\pm}1582.3g/dL$), and low glucose levels ($88.1{\pm}523.5mg/dL$). Findings from pleural fluid cultures were positive in 80 cases(65.6 percent). The most common causative agent was Streptococcus pneumoniae. The majority of patients were treated with antibiotics and closed drainage. Some patients needed open drainage (16.4 percent) or decortication (3.3 percent). The mean duration of hospitalization was $28.6{\pm}15.3days$. Conclusion : We analyzed childhood empyema patients during a period of 5 years in Korean children. The most frequent age group was 1-3 years and the most common causative agent was Streptococcus pneumoniaeiae. The majority of patients were treated with antibiotics and close drainage.