• Title/Summary/Keyword: 세정수

Search Result 676, Processing Time 0.033 seconds

A Study on Direct Cooling and Washing Machine for Energy Saving-Type Dyeing Machine (에너지 절감형 염색기용 직접냉각수세장치에 대한 연구)

  • Han, Seung-Chul;Kim, Jin-Ho;Kim, Je-Hoon;Lee, Sung-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.485-491
    • /
    • 2012
  • Due to increase in production of the domestic textile industry, energy consumption in textile industry is still growing. Traditional dyeing machine has high temperature and pressure. Accordingly, it uses an indirect cooling system that utilize a heat exchanger to cool after the dyeing. However, this indirect cooling system consumes a great deal of water, takes prolonged periods of time to process and, most importantly, because of the condensing of the dye at the cooling stage requires further energy in reduction cleaning and washing process. Therefore, in this paper, we propose a direct cooling washing machine that replaces the traditional indirect cooling system to provide coolant into the dyeing machine. The newly proposed direct cooling washing machine will still use parts of the traditional dying but will be able to skip the cooling as well as the reduction cleaning and washing process, resulting in less processing time and lower energy consumption. Also, we made a prototype. The prototype was applied to dyeing machine to test the direct cooling washing machine's ability and dyeing property. Additionally, we compared indirect cooling washing machine with direct cooling washing machine about ability, material and energy saving assessment.

The effect of MTAD on the apical leakage of obturated root canals: an electrochemical study (MTAD의 치근단 누출에 미치는 영향에 대한 전기화학적 연구)

  • Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of newly developed endodontic root canal cleanser (MTAD) on the apical leakage of obturated root canal using an electrochemical method. Canals of 60 extracted single-rooted human teeth were prepared by using a crown-down technique with rotary nickel-titanium files. In Group 1 (positive control group) and 2 (negative centre) group), 5.25% NaOCl was used as a canal irrigant and no canal wall treatment was done. In group 3 only 5.25% NaOCl were used as canal irrigant, canal wall treatment and final rinse. In group 4, specimens were irrigated with 5.25% NaOCl, treated with 5 ml of 17% EDTA for 5 minutes and final rinsed with 5.25% NaOCl Specimens of group 5 were irrigated with 1 3% NaOCl and treated with 5 ml of MTAD for 5 minutes. All root canals are dried with paper points and obtuated with gutta-percha and AH plus as a sealer using a continuous wave of condensation technique except in the group 1. The electrical resistance between the standard and experimental electrodes in canals was measured over a period of 10 days. Rising of apical leakage with time was observed for all the groups. Group 4 and 5 showed lower apical leakage than group 3 but differences between the group 3, 4 and 5 were no statistical significance at any measurement time.

Characterization of Membrane Fouling and It's Optimal Chemical Cleaning Method in MF Process using D dam water (D댐수를 이용한 정밀여과 공정에서 막오염 특성 및 최적 화학세정방법 조사)

  • Kim, Chung H.;Lim, Jae L.;Lee, Byung G.;Chae, Seon H.;Park, Min G.;Park, Sang H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.559-569
    • /
    • 2007
  • The purposes of this study were to find the main foulant of membrane and the optimal chemical cleaning method for MF(microfiltration) drinking water treatment system using D dam water as water source. The MF pilot plant which can treat maximum $500m^3/d$ consisted of 3 racks and was operated for 10 months under various operation conditions. After 10 months operation, $1^{st}$ and $2^{nd}$ rack of membrane pilot plant system were cleaned chemically and the degree of the restoration of the fouled membrane in terms of the pure water flux was detemnined. Inorganic compounds which contained in chemical cleaning waste was analyzed by Inductively Coupled Plasma (ICP). One membrane module for 3rd rack was disjointed and membrane fouling materials, especially inorganic compounds were investigated by Electron Probe Microanlysis (EPMA) to elucidate the reason of TMP increase. And also, the various chemical reagents (1N HCl or $H_2SO_4$, oxalic acid as acid and 0.3% NaOCl as alkali) were tested by combination of acid and alkali to determine the optimal chemical cleaning method for the MF system using micro-modules manufactured using the disjointed module. It was verified that the inside and outside of membrane module was colorized with black. As a result of the quantitative and semi-qualitative analysis of membrane foulant by ICP, most of inorganic foulant was manganese which is hard to remove by inorganic acid such as HCI. Especially, it was observed by EPMA that Mn was attached more seriously in inside surface of membrane than in outside surface of that. It was supposed that Mn fouling in inside surface of membrane might be caused by the oxidation of soluble manganese (Mn(II)) to insoluble manganese ($MnO_2$) by chlorine containing in backwashing water. The optimal cleaning method for the removal of manganese fouling was consecutive cleaning with the mixture of 1N HCl and 1% of oxalic acid, 0.3% NaOCl, and 1N HCl showing 91% of the restoration of the fouled membrane.

Effect of Intermittent Pressure-Assisted Forward Osmosis (I-PAFO) Operation on Colloidal Membrane Fouling and Physical Cleaning Efficiency (가압형 정삼투의 간헐적 운전이 콜로이드 파울링 및 물리세정 효율에 미치는 영향)

  • Lee, Jinwoo;Kook, Seungho;Kim, Sung-Jo;Kim, In S.
    • Membrane Journal
    • /
    • v.26 no.4
    • /
    • pp.273-280
    • /
    • 2016
  • Pressure assisted forward osmosis (PAFO) is recently introduced because of its improved process efficiency to overcome drawbacks of forward osmosis (FO) such as low water flux and reverse solute diffusion. However, it is known that membrane fouling becomes deteriorated by additional hydraulic pressure applied in PAFO compared to FO. This study was performed to investigate possibility of intermittent pressure-assisted forward osmosis (I-PAFO) operation for fouling mitigation using colloidal silica particles as model foulants. FO, PAFO were operated as well to compare with. Two different solution pH conditions (pH 3, 10) were applied to see the effect of electrostatic interactions between the membrane and silica particles on fouling tendency. In the results, higher water flux was observed during pressurization and pressure relaxation periods in I-PAFO than water flux of PAFO, and FO on both pH conditions. Water flux decreased less in I-PAFO than PAFO after fouling. It resulted in higher water flux recovery in I-PAFO than PAFO after physical cleaning.

Recovery of Cobalt from Synthetic Leaching Solution of Manganese Nodule Matte by Solvent Extraction-electrowinning (용매추출-전해채취법에 의한 망간단괴 매트상 모의 침출용액으로부터 코발트 회수)

  • Kim, Hyun-Ho;Nam, Chul-Woo;Park, Kyung-Ho;Yoon, Ho-Sung;Kim, Min-Seuk;Kim, Chul-Joo;Park, Sang-Woon
    • Resources Recycling
    • /
    • v.25 no.2
    • /
    • pp.33-41
    • /
    • 2016
  • A scale up tests (380 kg/day) using a continuous solvent extraction and electro-winning system was carried out to separate and recover cobalt from a solution containing 1.91 g/L Co and 14.65 g/L Ni. The solution was obtained during a process including solvent extraction and precipitation stages for removal of Cu and Fe from a synthetic sulfuric acid solution of manganese nodule matte. The optimal condition for solvent extraction was : solvent concentration of 0.22M Na-Cyanex 272 (45% saponified with NaOH) and O:A phase ratios of 1:1.5, 10:1 and 1.5:1 used in extraction, scrubbing and stripping stages, respectively. The extraction and stripping efficiencies were found to be 99.8% and 99.88%, respectively. The stripped solution contained 40.27 g/L Co with 4 ppm Ni. Cobalt metal of 99.963% purity was yielded with current efficiency of 67% and current density of $0.563A/dm^2$ during the electro-winning process.

Empirical Study of High Quality Solar Salt Production System (고품질 천일염 생산공정의 실증연구)

  • Han, Jae Woong;Kim, Hoon;Kim, Woong;Lee, Hyo-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.128-133
    • /
    • 2020
  • This study was conducted to demonstrate the manufacturing process for producing high-quality solar salt. The design criteria of the manufacturing process, which was studied in a previous study, was applied to an actual manufacturing system to evaluate its performance. The design factors applied were the drying air temperature and the temperature of the washing water. They were 100℃ or less and 10℃ or less, respectively. Two standards were applied to the process performance evaluation. Standard (I) was the international food standard for solar salt, and standard (II) was the quality standard for high-quality solar salt production. The main quality evaluation items were the moisture content and salinity, and the color characteristics were also measured (p<0.05). The manufacturing process of solar salt consisted of five steps, and the quality change was measured for each step. The measured quality was appropriate to the standard (I) from the third-step process. In addition, the quality of the high-quality solar salt was suitable for the standard (II) from the fourth-step process. Therefore, the performance of the proposed solar salt production process met international standards. The improvements in the production of high-quality solar salt will improve international competitiveness in the future.

Annual Reproductive Cycle of the Banded Catfish, Pseudobagrus fulvidraco (Richardson) (동자개, Pseudobagrus fulvidraco (Richardson)의 생식년주기)

  • LIM Sang-Koo;HAN Chang-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.5
    • /
    • pp.823-833
    • /
    • 1997
  • To clarify the annual reproductive cycle of the banded catfish, Pseudobagrus fulvidraco (Richardson), the seasonal changes in histological aspect of gonad and liver were examined. The adult fish was raptured from the upper stream of Young-San river, Chunnam in each month from May 1992 to June 1993. Based on the annual changes in GSI (gonadosomatic index), HSI (hepatosomatic index), CF (condition factor) and histological aspects of the gonads, the annual reproductive cycle were classified into 5 periods as follows: 1) Growing phase (from April to early May): The value of GSI increased and the size of oocytes in perinucleolus stage in oocytes increased gradually. Spermatogonia were developed actively from the epithelial tissues of seminiferous tubules. 2) Maturing phase (from Hay to early June): GSI levels increased rapidly in both sex. Oocytes at various developmental stages were observed. Appearance of active spermatogenesis were observed. 3) Mature and spawning phase (from June to August): High values of GSI remained static and oocytes accumulated significant quantitis of yolk globules. 4) Degenerating phase (from September to November): GSI levels decreased and ovaries were filled mostly with oocytes at the perinucleolus stage. Hepatic cells accumulated significant amounts of lipid droplets. 5) Resting period (from December to March) : Low values of GSI were kept and the size of oocytes at the perinucleolus stage did not increase. Spermatogenesis was not observed.

  • PDF

Deterioration Diagnosis and Conservation Treatment of the Jincheon Sagongnimaaeyeoraeipsang (Stone Relief of Standing Buddha in Sagok-ri), Korea (진천 사곡리 마애여래입상의 훼손도 진단과 보존처리)

  • Kim, Sa-Dug;Lee, Myeong-Seong;Han, Byeong-Il;Lee, Jang-Jon;Song, Chi-Young
    • Journal of Conservation Science
    • /
    • v.25 no.3
    • /
    • pp.323-333
    • /
    • 2009
  • The Jincheonsagongnimaaeyeoraeipsang is a great stone relief Buddha in Goryeo Dynasty, transmitting sculptural styles of the Silla Kingdom. The Buddha was carved on the biotite granite basement, and was undergone cleaning treatment in 2007. The basement rock was opened in plenty cracks bringing out structural instability. And the top of the basement rock was colonized by trees obstructing sunshine and raising humidity. As a result of failure analysis, the basement rock of the Buddha had a major possibility of wedge failure in the parts of the face, hands and cloths. Therefore, the cracks were filled up with epoxy resin L-50, and titanium bars and wire ropes were applied to bind cracked rock blocks. The surface of the crack filler was colored by granite and talc powder with inorganic pigment and L-30. The crack meters were installed on the stone relief Buddha to monitor further behavior, lastly.

  • PDF

Optimum Remediation Conditions of Vertical Electrokinetic-Flushing Equipment to Decontaminate a Radioactive Soil (방사성토양 복원을 위한 수직형 동전기-세정장치의 최적제염조건 도출)

  • Kim, Gye-Nam;Yang, Byeong-Il;Moon, Jei-Kwon;Lee, Kune-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.153-160
    • /
    • 2009
  • Vertical electrokintic-flushing remediation equipment was developed for the remediation of a radioactive soil near nuclear facilities. An optimum reagent was selected to decontaminate the radioactive soil near nuclear facilities with the developed vertical electrokintic-flushing remediation equipment, and the optimum remediation conditions were established to obtain a higher remediation efficiency. Namely, acetic acid was selected as an optimum reagent due to its higher remediation efficiency. When the electrokinetic remediation and the electrokinetic-flushing remediation results were compared, the removal efficiency of 4.6% and the soil waste solution volume of 1.5 times were increased in the electrokinetic remediation. When the potential gradient within an electrokinetic soil cell was increased by two times (4.0 V/cm), the removal efficiencies of $Co^{2+}$ and $Cs^+$ were increased by about 4.3%($Co^{2+}$ : 98.9%, $Cs^+$ : 96.7%). Also, when the reagent concentration was increased from 0.01M to 0.05M, the removal efficiency of $Co^{2+}$ was increased but that of $Cs^+$ was decreased. Therefore, the optimum remediation conditions were that the acetic concentration was $0.01M{\sim}0.05M$, the potential gredient was 4 V/cm, the injection of reagent 2.4ml/g, and the remediation period was 20days.

  • PDF

Characteristics of Heat Recovery Rate and Fouling according to Structures and Materials in Heat Exchangers (열교환장치의 구조 및 재질에 따른 열회수율과 파울링의 발생 특성)

  • Kim, Hyun-Sang;Kim, Yong-Gu;Bong, Choon-Keun;Lee, Myong-Hwa
    • Resources Recycling
    • /
    • v.24 no.2
    • /
    • pp.3-12
    • /
    • 2015
  • We researched characteristics of heat recovery rate and fouling according to structures and materials in heat exchangers like water preheater and air preheater. Economizer and air preheater have used in thermal electric power plant. we made small incinerator and heat exchangers to carry out simulated experiment. We observed fouling formation and change of heat recovery rate, combusting powdered coal for 24 hr. In economizer, fin tube type had the largest amount of fouling formation, followed by tube line type > pipe type > auto washing type according to structures. As heat recovery rate, fin tube showed highest recovery rate, followed by auto washing type > pipe type > tube line type. In air preheater, fin tube type had the largest amount of fouling formation, followed by fin plate type > pipe type > pipe type coated by teflon > pipe type coated by ceramic according to structures. And then, heat recovery rate showed the same oder.