판형 열교환기의 세브론각에 따른 응축열전달 및 압력강하 실험 (Experiments on Condensation Heat Transfer and Pressure Drop in Plate Heat Exchangers with Different Chevron Angles)

  • 김윤호;한동혁;이규정
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1141-1148
    • /
    • 2001
  • Experiments on the condensation heat transfer and pressure drop in the brazed type plate heat exchangers are performed with refrigerants R410A/R22. To investigate the geometric effect, plate heat exchangers with the same pitch and height but different $45^{\circ},\;35^{\circ}and\;20^{\circ}$ chevron angles are used. Varying the mass flux of refrigerant (13~34 kg/$m^2$), the condensing temperatures ($20^{\circ}C\;and\;30^{\circ}C$) and the vapor quality (from 0.9 to 0.15) at the same constant heat flux ($5kW/m^2$), the condensation heat transfer coefficients and pressure drops are measured. The heat transfer coefficients decrease slightly with increasing the condensing temperature at a given mass flux in all plate heat exchangers. The pressure drop increases with increasing the mass flux and the quality and decreasing the condensing temperature and the chevron angle.

  • PDF

판형열교환기를 적용한 청수제조장치의 성능 및 채널내 유동 (Performance of A Fresh Water Generator Applied Plate Heat Exchangers and Flow in the Channel)

  • 김진화;지명국;이광성;정한식;정효민
    • 동력기계공학회지
    • /
    • 제13권5호
    • /
    • pp.5-10
    • /
    • 2009
  • 본 연구에서는 판형열교환기를 적용한 청수제조장치의 성능에 대하여 연구를 수행하였다. 판형열교환기는 자체의 높은 열전달 성능과 컴펙트한 장점으로 하여 산업에서 점차 널리 사용되고 있다. 또한 사용, 유지보수가 다른 종류의 열교환기에 비하여 편리하여 유연성 있게 사용할 수 있다. 본 실험에서는 세브론 각도가 60도인 전열판을 사용하였으며 이젝터의 작동으로 열교환기를 장착하고 있는 탱크내부에 진공압력을 유지함으로서 내부유체가 $51^{\circ}C{\sim}57^{\circ}C$에서 증발현상이 발생하는 것을 확인하였다. 또한 수치해석적 방법을 통하여 복잡하며 좁은 세브론전열판으로 이루어진 유로내의 유동특성을 파악할 수 있었다.

  • PDF

기구적 설계변수에 따른 판형열교환기의 성능특성 (Performance Characteristics of Plate Heat Exchangers with Various Geometric Design Parameters)

  • 손재욱;이응찬;강훈;김용찬;김정규;조성열;박재홍
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.583-591
    • /
    • 2012
  • 판형열교환기는 높은 효율로 인하여 다양한 산업 분야에 사용되고 있으며, 판형열교환기의 성능특성을 파악하기 위해 많은 연구가 이루어 졌다. 하지만 세브론 각을 제외한 판형열교환기의 기구적 설계변수에 따른 성능특성 파악은 상대적으로 많이 부족한 실정이다. 본 연구는 판형열교환기의 기구적 설계변수에 따른 열전달 및 압력강하 성능특성을 파악하기 위해서 세브론 각, 전열판 골 깊이, 전열판골 길이, 전열판 개수 등을 변화시키며 실험을 수행하였다. 실험결과를 바탕으로 판형열교환기의 다양한 기구적 설계변수를 반영한 열전달 및 압력강하 성능특성 상관식을 제안하였다. 실험 데이터와 제안된 판형열교환기 상관식을 이용해 예측된 데이터를 비교한 결과 약 95% 이상의 데이터가 ${\pm}10%$ 오차범위 내에 존재함을 알 수 있었다.

판형 열교환기의 피치 및 세브론각이 열에너지 성능에 미치는 영향 (Effects of Plate Pitch and Chevron Angle in a Plate Heat Exchanger on Thermal Energy Performance)

  • 강병하;한상규
    • 한국수소및신에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.194-200
    • /
    • 2004
  • Thermal energy performance of a brazed plate heat exchanger has been evaluated experimentally. The effects of plate pitch as well as chevron angle of a plate heat exchanger on the heat transfer rate and pressure drop have been investigated in the wide range as mass flow rates in detail. This problem is of particular interest in the design of a plate heat exchanger. The results obtained indicate that both heat transfer rate and pressure drop are increased as mass flow rate is increased, as expected. It is also found that the heat transfer rate is increased with a decrease in the plate pitch while the heat transfer is decreased with a decrease in the chevron angle. Friction factor correlations are suggested based on the measured pressure drop and effectiveness of plate heat exchangers are also compared.

판형열교환기의 세브론각에 따른 증발 열전달특성 및 압력강하에 대한 실험적 연구 (An Experimental Study on Evaperation Heat Transfer and Pressure Drop in Plated cleat Exchangers with Different Chevron Angles)

  • 김윤호;이규정
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.269-277
    • /
    • 2002
  • Experiments on the evaporation heat transfer and pressure drop in the brazed type plate heat exchangers were performed using refrigerants R410A and R22. To investigate the geometric effect, plate heat exchangers with the same pitch and height but different 45$^{\circ}$, 35$^{\circ}$and 20$^{\circ}$chevron angles are used. Tests were conducted fur the ranges of the mass flux of refrigerant from 13 kg/m$^2$s to 34 kg/m$^2$s, the evaporation temperatures of 15$^{\circ}C$, 1$0^{\circ}C$ and 5$^{\circ}C$, vapor quality from 0.15 to 0.95 and the heat flux from 2.5 kW/m$^2$to 8.5 kW/m$^2$. The evaporation heat transfer coefficients and pressure drops were measured. Most of flow patterns are in the chum flow regime and become close to the annular flow for increasing the mass flux and the vapor quality. The heat transfer coefficient increases with increasing the evaporation temperature at a given mass flux in all plate heat exchangers. Also, the pressure drop increases with increasing the mass flux and the quality and decreasing the evaporation temperature and the chevron angle.