• Title/Summary/Keyword: 세기조절 방사선치료

Search Result 154, Processing Time 0.027 seconds

Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy (국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료)

  • Choi Chul-Won;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Yoo Hyung-Jun;Lee Dong-Han;Ji Young-Hoon;Han Chul-Ju;Kim Jin;Kim Young-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.11-20
    • /
    • 2006
  • Puroose: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. Materials and Methods: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status ${\leq}3$ and locally advanced pancreas cancer without distant metastasis, evaluated by CT or PET/CT, were included. We administered stereotactic RT consisting of either 33 Gy, 36 Gy or 39 Gy in 3 fractions to 6, 4 and 9 patients, respectively, in an effort to increase the radiation dose step by step, and analyzed the survival rate and gastrointestinal toxicities by the acute radiation morbidity criteria of Radiation Therapeutic Oncology Group (RTOG). Prognostic factors of age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9, planning target volume (PTV), and adjacent organ and vessel invasion on CT scan were evaluated by Log Rank test. Results: The median survival time was 11 months with 1-year survival rate of 36.8%. During follow-up period (range $3{\sim}20$ months, median 10 months), no significant gastrointestinal acute toxicity (RTOG grade 3) was observed. In univariate analysis, age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9 level, and adjacent organ and vessel invasion did not show any significant changes of survival rate, however, patients with PTV (80 cc showed more favorable survival rate than those with PTV>80 cc (p-value<0.05). In multivariate analysis, age younger than 65 years and PTV>80 cc showed better survival rate. Conclusion: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Study on the beam properties of small field sizes (소조사면 전량분포의 특성에 관한 고찰)

  • Cho JeongHee;Lee SangKyu;An SeungKwon;Park Jell
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Purpose : The aim of this study is to investigate the properties of small field size and to measure the penumbra and central axis depth dose varying to the jaw setting and off axis distance for indicate this data to small field sizes radiation therapy. Material and methods : The percentage depth dose, beam profile and central axis output dose was measured by farmer type ion chamber and pinpoint chamber using Primart linac with 6MV energy. Beam quality and penumbra variations according to the central axis shift, from center to every 2cm outside increment, and field size, from $1{\times}1cm$ to $10{\times}10cm$ was investigated and compared with that of the standard geometrical condition's results Results : The differences of measured values between two ion chamber was about $37\%$ at 10cm depth with $1{\times}1cm$ field sizes but as field size increased this differences was diminished gradually. Measured data from various off axis distance with the different asymmetric collimations are not changed significantly but as size decreased the dose variation was increased and at $1{\times}1cm$ field size dose difference among off axis distance was as much as $13\%$, and as shallower the measured depth the central axis dose variations among the OAD was increased, penumbra was not changed noticeably depending on off axis distance but the percentage of penumbra from its initial field sizes was strongly dependant on field sizes and penumbra occupation rates of its own field sizes ranging from $6\%$ at $10{\times}10cm$ to $50\%$ at $1{\times}1cm$ field size. Conclusion : For imrt treatment, there are several numbers of different gentry angles with beams of nonuniform fluences are required and several complex factors involved. Among them the characteristics of beam output varying to the geometrical setting and design of collimators are of important to attaining a good treatment results. As mentioned in results the differences of measured values are changed significantly depends on ion chamber volume, depths and field size. For providing quality radiation treatment, especially at small field size, those factor's should have considering deliberately.

  • PDF

Evaluation of Xerostomia Following Intensity Modulated Radiotherapy (IMRT) for Head and Neck Cancer Patients (세기조절방사선치료를 시행받은 두경부암 환자군에서 구강건조증지표 분석)

  • Lee, Seok-Ho;Kim, Tae-Hyun;Chie, Eui-Kyu;Im, Hyun-Shun;Im, En-Shil;Ryu, Jun-Sun;Jung, Yoo-Seok;Park, Sung-Yong;Kim, Joo-Young;Pyo, Hong-Ryull;Shin, Kyung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.106-114
    • /
    • 2004
  • Purpose : This study was done to evaluate xerostomia fellowing intensity modulated radiotherapy for patients with head and neck cancer, and to analyze the correlation between the dosimetric parameters and xerostomia parameters. Materials and Methods : From February till October 2003, 13 patients with 3 months of follow-up were evaluated for xerostomia after being treated for head and neck cancer with IMRT. Their median age was 57 years(range: 43$\~$77). Xerostomia were assessed with a 4-question xerostomia questionnaire score (XQS) and a test for salivary flow rates (unstimulated and stimulated). The patients were also given a validated LENT SOMA scale (LSC) questionnaire. The evaluations were completed before radiation therapy (pre-RT) and at 1 and, 3 months after radiation therapy (RT). We evaluated xerostomia at pre-RT, 1 and, 3 months after RT. The association between the xerostomia parameters (XQS and LSC) and salivary flow rates (unstimulated and stimulated: USFR and SSFR) was assessed at 1 and 3 months after RT. Resrlts : All 13 patients showed no significant changes in XQS, LSC and Salivary Flow rates. As a result, we couldn't find out about xerostomia development. Based on the total mean parotid dose, 3,500 cGy, we divided these patients into two groups. The 8 patients (<3,500 cGy) showed no significant changes in XQS, LSC and Salivary Flow rates However, in 5 Patients ($\geq$3,500 cOGy), there was a significant increase in USFR and, SSFR at 3 months after RT, and for the XQS and, LSC at 1 and 3 months after RT. The correlation between XQS and, LSC, and USFR and, SSFR in ail patients (13) was significant at 3 months after RT. The correlation had a tendency to the decrease for USFR and, SSFR in proportion to the increase of XQS and, LSC. Conclusion : Based on the results of this study, IMRT seem to be an effective treatment to significantly decrease the xerostomia. XQS and, LSC seem to be a effective tool for predicting the xerostomia. A total parotid gland mean dose of <3,500 cGy should be a planning goal if substantial sparing of the gland function is desired. Furthermore, patients should be enrolled in a study to define a more accurate threshold dose for the parotid gland.

Assessment of the Usefulness of an IMRT Plan Using a Shell-Type Pseudo Target with Patients in Stage III or IV of NSCLC (비소세포폐암 III, IV기 환자에 있어서 Shell-Type Pseudo Target을 이용한 세기 조절 방사선치료계획기법의 유용성 평가)

  • Lee, Sang-Bong;Park, Ki-Ju;Park, Du-Chan;Kim, Man-Wo;Kim, Jun-Gon;Noh, Sung-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.95-106
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the usefulness of an IMRT treatment plan according to whether there was a shell-type pseudo target during radiation therapy for patients in Stage III or IV of non-small cell lung cancer (NSCLC). Materials and Methods: After setting an IMRT (Intensity-Modulated Radiation Therapy, IMRT) plan for when there was a shell-type pseudo target (SPT) and when there was none (WSPT) with 22 patients in Stage III or IV of NSCLC, the investigator analyzed dose-volume histograms (DVHs) and made assessment with dosimetric comparisons such as homogeneity index (HI) inside the tumor target, conformity index (CI) of the tumor target, spinal cord maximum dose, Esophagus $V_{50%}$, mean lung dose (MLD), and $V_{40%}$, $V_{30%}$, $V_{20%}$, $V_{10%}$, $V_{5%}$. Results: The mean CI of WSPT and SPT was $1.22{\pm}0.04$ and $1.16{\pm}0.032$ ($.000^*$), respectively, and the mean HI of WSPT and SPT was $1.06{\pm}0.015$ and $1.07{\pm}0.014$ ($.000^*$), respectively. In SPT, the mean of each CI difference decreased by $-5.16{\pm}2.54%$, while HI increased by average $0.81{\pm}0.47%$. Esophagus $V_{50%}$ recorded $14.54{\pm}12.01%$ (WSPT) and $12.14{\pm}11.09%$ ($.000^*$, SPT) with the mean of SPT differences dropping by $-26.37{\pm}25.05%$. Mean spinal cord maximum dose was $3,898.44{\pm}1,075.0$ cGy (WSPT) and $3,810.8{\pm}1,134.9$ cGy ($.004^*$, SPT) with SPT dropping by average $-3.36{\pm}5.81%$. As for lung $V_{X%}$, the mean of $V_{5%}$ and $V_{10%}$ differences was $-1.62{\pm}2.29%$ ($.006^*$) and $-1.98{\pm}5.02%$ ($.005^*$), respectively with SPT making a decrease. The mean of V20%, V30%, and V40% differences was $-3.51{\pm}3.07%$ ($.000^*$), $-4.84{\pm}6.01%$ ($.000^*$), and $-6.16{\pm}8.46%$ ($.001^*$), respectively, with SPT making a decrease with statistical significance. In MLD assessment, SPT also dropped by average $-2.83{\pm}2.41%$ ($.000^*$). Those results show that SPT allows for mean 169 cGy (Max: 547 cGy, Min: 6.4 cGy) prescription dose. Conclusion: An IMRT treatment plan with SPT during radiation therapy for patients in Stage III or IV of NSCLC will help to reduce the risk of lung toxicity and radiation-induced pneumonia by cutting down radiation doses entering the normal lung, reduce the local control failure rate during radiation therapy due to increasing prescription doses to a certain degree, and increase treatment effects.

  • PDF

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Experiences of the First 130 Patients in Gangnam Severance Hospital (강남세브란스병원 토모테라피를 이용한 치료환자의 130예 통계분석 및 경험)

  • Ha, Jin-Sook;Jeon, Mi-Jin;Kim, Sei-Joon;Kim, Jong-Dae;Shin, Dong-Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • Purpose: We are trying to analyze 130 patients' conditions by using our Helical Tomotherapy, which was installed in our center in Oct. 2007. We will be statistically approach this examination and analyze so that we will be able to figure out adaptive plans according to the change in place of the tumor, GTV (gross tumor volume), total amount of time it took, vector (${\upsilon}=\surd$x2+y2+z2) and the change in size of the tumor. Materials and Methods: Objectives were the patients who were medicated with Tomotherapy in our medical center since Oct. 2007 August 2008. The Average age of the patients were 53 years old (Minimum 25 years old, Maximum 83 years old). The parts of the body we operated were could be categorized as Head&neck (n=22), Chest (n=47), Abdomen (n=25), Pelvis (n=11), Bone (n=25). MVCT had acted on 2702 times, and also had acted on our adaptive plan toward patients who showed big difference in the size of tumor. Also, after equalizing our gained MVCT and kv-CT we checked up on the range of possible mistake, using x, y, z, roll and vector. We've also investigated on Set-up, MVCT, average time of operation and target volume. Results: Mean time on table was 22.8 minutes. Mean treatment time was 13.26 minutes. Mean correction (mm) was X=-0.7, Y=-1.4, Z=5.77, roll=0.29, vector=8.66 Head&neck patients had 2.96 mm less vector value in movement than patients of Chest, Abdomen, Bone. In increasing order, Head&neck, Bone, Abdomen, Chest, Pelvis showed the vector value in movement. Also, there were 27 patients for adaptive plan, 39 patients, who had long or multiple tumor. We could know that When medical treatment is one cure plan, it takes 32 minutes, and when medical treatment is two cure plan, it takes 40 minutes that one medical treatment takes 21 minutes, and the other medical treatment takes 19 minutes. Conclusion:With our basic tools, we could bring more accurate IMRT with MVCT. Also, through our daily image, we checked up on the change in tumor so that adaptive plan could work. It was made it possible to take the cure of long or multiple tumor, the cure in a nearby OAR, and the complicated cure that should make changes of gradient dose distribution.

  • PDF

Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging (전자포탈영상을 이용한 다엽시준기의 정도관리)

  • ;Jason W Sohn
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.151-160
    • /
    • 2003
  • The application of more complex radiotherapy techniques using multileaf collimation (MLC), such as 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT), has increased the significance of verifying leaf position and motion. Due to thier reliability and empirical robustness, quality assurance (QA) of MLC. However easy use and the ability to provide digital data of electronic portal imaging devices (EPIDs) have attracted attention to portal films as an alternatives to films for routine qualify assurance, despite concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In this study, we developed method for daily QA of MLC using electronic portal images (EPIs). EPID availability for routine QA was verified by comparing of the portal films, which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed two-test patterns of dynamic MLC were applied for image acquisition. Quantitative off-line analysis using an edge detection algorithm enhanced the verification procedure as well as on-line qualitative visual assessment. In conclusion, the availability of EPI was enough for daily QA of MLC leaf position with the accuracy of portal films.

  • PDF

Analysis of Radiation Treatment Planning by Dose Calculation and Optimization Algorithm (선량계산 및 최적화 알고리즘에 따른 치료계획의 영향 분석)

  • Kim, Dae-Sup;Yoon, In-Ha;Lee, Woo-Seok;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • Purpose: Analyze the Effectiveness of Radiation Treatment Planning by dose calculation and optimization algorithm, apply consideration of actual treatment planning, and then suggest the best way to treatment planning protocol. Materials and Methods: The treatment planning system use Eclipse 10.0. (Varian, USA). PBC (Pencil Beam Convolution) and AAA (Anisotropic Analytical Algorithm) Apply to Dose calculation, DVO (Dose Volume Optimizer 10.0.28) used for optimized algorithm of Intensity Modulated Radiation Therapy (IMRT), PRO II (Progressive Resolution Optimizer V 8.9.17) and PRO III (Progressive Resolution Optimizer V 10.0.28) used for optimized algorithm of VAMT. A phantom for experiment virtually created at treatment planning system, $30{\times}30{\times}30$ cm sized, homogeneous density (HU: 0) and heterogeneous density that inserted air assumed material (HU: -1,000). Apply to clinical treatment planning on the basis of general treatment planning feature analyzed with Phantom planning. Results: In homogeneous density phantom, PBC and AAA show 65.2% PDD (6 MV, 10 cm) both, In heterogeneous density phantom, also show similar PDD value before meet with low density material, but they show different dose curve in air territory, PDD 10 cm showed 75%, 73% each after penetrate phantom. 3D treatment plan in same MU, AAA treatment planning shows low dose at Lung included area. 2D POP treatment plan with 15 MV of cervical vertebral region include trachea and lung area, Conformity Index (ICRU 62) is 0.95 in PBC calculation and 0.93 in AAA. DVO DVH and Dose calculation DVH are showed equal value in IMRT treatment plan. But AAA calculation shows lack of dose compared with DVO result which is satisfactory condition. Optimizing VMAT treatment plans using PRO II obtained results were satisfactory, but lower density area showed lack of dose in dose calculations. PRO III, but optimizing the dose calculation results were similar with optimized the same conditions once more. Conclusion: In this study, do not judge the rightness of the dose calculation algorithm. However, analyzing the characteristics of the dose distribution represented by each algorithm, especially, a method for the optimal treatment plan can be presented when make a treatment plan. by considering optimized algorithm factors of the IMRT or VMAT that needs to optimization make a treatment plan.

  • PDF

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.