• Title/Summary/Keyword: 성형 하중

Search Result 241, Processing Time 0.027 seconds

Evaluation of press formability of pure titanium sheet (순 티탄늄 판재의 프레스 성형성 평가(제 1보))

  • Kim, Young-Suk;In, Jeong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.380-388
    • /
    • 2016
  • Commercially pure titanium (CP Ti) has been actively used in plate heat exchangers due to its light weight, high specific strength, and excellent corrosion resistance. However, compared with automotive steels and aluminum alloys, there has not been much research on the plastic deformation characteristics and press formability of CP Ti sheet. In this study, the mechanical properties of CP Ti sheet are clarified in relation to press formability, including anisotropic properties and the stress-strain relation. The flow curve of the true stress-true strain relation is fitted well by the Kim-Tuan hardening equation rather than the Voce and Swift models. The forming limit curve (FLC) of CP Ti sheet was experimentally evaluated as a criterion for press formability by punch stretching tests. Analytical predictions were also made via Hora's modified maximum force criterion. The predicted FLC with the Kim-Tuan hardening model and an appropriate yield function shows good correlation with the experimental results of the punch stretching test.

The Experimental Study of the Ultimate Behavior of an Avalanche Tunnel Corner Rigid Joint Composited with a Centrifugal Formed Beam (초고강도 원심성형 보가 합성된 피암터널 우각부의 극한거동에 관한 실험연구)

  • Lee, Doo-Sung;Kim, Sung-Jin;Kim, Jeong-Hoi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.128-138
    • /
    • 2022
  • In this study, in order to apply ultra-high-strength concrete beams of 100 MPa or more manufactured by centrifugal molding as the superstructure of the avalanche tunnel, the purpose is to verify the structural safety of the corner rigid joint in which the centrifugal molded beam is integrated with the substructure, which is the negative moment area. A full-size specimen was manufactured, and loading tests and analysis studies were performed. In order to expect the same effect that the maximum moment occurs in the corner joint part of the upper slab end when the standard model of the avalanche tunnel is designed with a load combination according to the specification, a modified cantilever type structural model specimen was manufactured and the corner rigid joint was fixedly connected. A study was performed to determine the performance of the method and the optimal connection construction method. The test results demonstrated that the proposed connection system outperforms others. Despite having differences in joint connection construction type, stable flexural behavior was shown in all the tested specimens. The proposed method also outperformed the behavior of centrifugally formed beams and upper slabs. The behavior of the corner rigid joint analysis model according to the F.E. analysis showed slightly greater stiffness compared to the results of the experiment, but the overall behavior was almost similar. Therefore, there is no structural problem in the construction of the corner rigid joint between the centrifugally formed beam and the wall developed in this study.

A Study on the Effects of Sample Preparation on Liquefaction Estimation Using Cyclic Triaxial Test Conditions (시편의 성형방법이 반복삼축압축시험을 이용한 지반의 액상화 평가에 미치는 영향에 관한 연구)

  • 이익효;김동수;김준석;황지훈;서성호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.57-64
    • /
    • 2003
  • The liquefaction potential of saturated sands under seismic loading conditions has been carefully considered by many investigations. Typical of these investigations is the laboratory determination of cyclic strength of sands by means of cyclic triaxial tests. This study was conducted to investigate the effects of the method of sample preparation on the liquefaction characteristics of remolded samples of saturated uniform sands. Cyclic triaxial tests were performed on saturated uniform sand compacted to the same density by 3 different procedures of pluvial compaction through air, pluvial compaction through water and vibratory compaction. It was validated that the cyclic stress ratio of remolded saturated uniform sands by different compaction procedures at the same density was very different.

The Critical Repeated Stress and Behavior of the Isotropic Normally Consolidated Clays Subjected to Repeated Loads. (반복하중을 받는 등방정친압밀점토의 거동 및 한계반복응력)

  • 김팔규;송전섭
    • Geotechnical Engineering
    • /
    • v.4 no.3
    • /
    • pp.43-52
    • /
    • 1988
  • The behavior of clays subjected to Repeated loading has been shown to be very different from the behavior under a single load application. Especially the behavior of pore water pressure is Qf considerable importance. The objective of this work is to experimentally study the stress-strain characteristics of clays, and this study includes the pore water pressure which is built up during the load repetition. For this study, the samples were consolidated isotropically in the triaxial cell during 24 hours, .and monotonic strain controlled triaxial test is carried out by uslng the tests of Compression failure, Cycled at failure, and Nonfailure equilibrium on remoulded samples under undrained .condition . Consequently there exists a critical level of repeated loading which seperates the behavior of a particular sample into two distinctly different patterns.

  • PDF

Sensitivity Analysis of a Bellows Expansion Joint subjected to Monotonic Loading Due to Structural Uncertainty (단조하중을 받는 벨로우즈 신축이음관의 구조적 불확실성에 의한 민감도 분석)

  • Son, Hoyoung;Lee, Jong-Ryun;Jeon, Bub-Gyu;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.305-306
    • /
    • 2023
  • 지반 침하 및 액상화 등에 따른 과도한 상대변위로 인한 매립배관 시스템의 손상을 저감시키기 위해 종종 벨로우즈 신축이음관은 사용된다. 벨로우즈 신축이음관의 성형과정에서 회선의 벽두께 감소와 같은 구조적인 불확실성이 발생할 수 있으며 특히, 벽두께 감소는 벨로우즈 신축이음관의 성능에 영향을 미칠 수 있다. 매립배관 시스템의 효율적인 유지관리를 위해 회선의 벽두께 감소에 의한 벨로우즈 신축이음관의 성능평가는 필요하다. 하지만 회선의 벽두께 감소가 벨로우즈 신축이음관의 성능에 미치는 영향을 조사하는 연구는 미미하다. 따라서 본 연구는 기초적인 연구로써 고충실도 유한요소 모델을 이용하여 단조하중을 받는 벨로우즈 신축이음관의 벽두께 감소에 의한 성능을 평가하고 민감도 분석을 수행하였다. 각 회선의 벽두께 감소를 20%로 적용하였을 때 최대하중은 약 3% 감소하는 것으로 나타났으며 2번 회선의 벽두께 감소가 최대하중 감소에 비교적 큰 영향을 미치는 것으로 나타났다.

  • PDF

Hot Forging Simulation of Outer Tie Rod for Reducing Forming Load (성형하중을 감소시키기 위한 아우터 타이로드의 열간 단조해석)

  • Kim, Young-Jun;An, Kyo-Jin;Lee, Kwon-Hee;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1652-1657
    • /
    • 2015
  • Recently the improvement in vehicle performance trend to increase in accordance with the weight of this part. Outer tie rod is small when compared to the other vehicle part by weight, but there is a need to reduce the weight of the outer tie rod in order to improve fuel efficiency of the vehicle. Therefore, from previous studies, a model of outer die rod is proposed using Design of Experiments and Meta model satisfying the buckling performance. Outer tie rod are manufactured through forging process, in this study, we compare the size of the forming load in accordance with the change in the moving speed through the die forging analysis of the outer tie rod on the basis of the actual molding process.

Ultimate Strength of Fillet-welded T-joints in Cold-formed Square Hollow Sections-chord web failure mode (냉간성형 각형강관 모살용접 T형 접합부의 최대내력(II)-주관웨브 파괴모드-)

  • Bae, Kyu Woong;Park, Keum Sung;Kang, Chang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.3
    • /
    • pp.403-411
    • /
    • 2002
  • This paper described the ultimate strength and deformation limit of welded T-joints in cold-formed square hollow sections. Previous studies showed that the T-joint has an obvious peak load. with the failure mode of chord-web buckling at a ratio of branch width to chord width ($\beta$) of above 0.8. Similar to a T-joint with chord-flange failure mode, the strength at a certain deformation limit can be regarded as the ultimate strength of a T-joint Based on the experimental results including tests done by Kato and Zhao, the deformation limit was proposed as 3%B for $10.7{\leq}2{\gamma}(B/T){\leq}42.3$ and $0.8{\leq}{\beta}{\leq}1.0$. The strength formula of CIDECT and those of other researchers were also compared with the test results. Finally, the strength formula based on the column buckling was proposed.

Optimal Design of the Tractrix Die Used in the DDI Process for Manufacturing CG Pressure Vessels (CNG 압력용기 제작을 위한 D.D.I. 공정의 Tractrix 다이 최적설계)

  • Lee, Kwang O;Sim, Hyeon Dae;Kwak, Hyo seo;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.10
    • /
    • pp.879-886
    • /
    • 2016
  • Tractrix dies, used in the deep drawing process, can be used to form CNG pressure vessels without a blank holder. Previous studies had only applied tractrix profiles to perform the first deep drawing process of DDI; but an optimal design of the tractrix die that focuses on improving die life and reducing production cost has not been performed yet. In this study, finite element analyses of deep drawing processes were conducted according to heights of the tractrix die by using translating asymptotes. In addition, researchers analyzed von-Mises stresses at the part of stress concentration of the die according to the forming punch loads in order to propose an optimal tractrix die design.

Case Study on the Explosive Demolition of Steel Truss Bridge using Charge Container for Cutting Structural Steel (강재 절단용 장약용기를 이용한 철골 교량 발파해체 시공사례)

  • Park, Hoon;Suk, Chul-Gi;Noh, You-Song
    • Explosives and Blasting
    • /
    • v.36 no.1
    • /
    • pp.20-33
    • /
    • 2018
  • A locally damaged structure is a structure that cannot be reused due to having parts that have lost their structural function as a result of abnormal load across the interior or exterior of the structure. The causes of the abnormal load occurrences can be classified into natural disaster and artificial disaster. Locally damaged structures caused by this abnormal load have risk factors that may lead to the possibility of additional secondary collapses, so such structures require immediate and complete dismantling. The case presented in this study involves the application of explosive demolition to a steel truss structured bridge in the Philippines that was damaged due to construction failures and the hurricane. Although shaped charges were needed in explosive demolitions, difficulties in locally obtaining such material. So, we made a charge container to charging of emulsion explosive during the explosive demolition. The explosive demolition resulted in the vertical free fall of the mid-section of the bridge and the free fall rotating of the both end section of the bridge. The neighboring posts and bridge piers did not show signs of damages, while post-demolition fragmentation of removed parts was found to be satisfactory.

An Experimental Study on the Fatigue Behaviors Strengthened by Ventilation-Glass Fiber Plate of Reinforced Concrete Beams (철근콘크리트 보의 통기성 유리섬유판 보강에 따른 피로거동에 관한 실험적 연구)

  • Kim, Woonhak;Kang, Seokwon;Shin, Chunsik
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.391-400
    • /
    • 2012
  • Recently, the construction industry commonly uses FRP as a reinforcement material because of its material advantages. FRP attached reinforcement has various advantages such as high strength, stiffness, excellent durability and construction practicability comparing to its weight. However, external attachment of FRP is water-tighted with low water permeable material, not draining water, probably causing damages on a permanent structure. The study manufactured it through pultrusion and examined GP(glass fiber panel) of which material-mechanical properties are almost same as the existing FRP but durability and attachment performance are better by stationary experiments, testing load-deflection curve, destruction types and load-deflection relation under repetitive loading test. As a result of 2,000,000 fatigue tests, it did not result in the destruction and showed excellent permanent attachment and durability as it displays significantly low compressive strain of concrete.