• Title/Summary/Keyword: 성정

Search Result 805, Processing Time 0.028 seconds

The Development of an On-line Supervision System (전기수용설비 상시 감시 시스템 개발)

  • Moon, Hak-Yong;Ryu, Seung-Ki;Choi, Do-Hyuk;Kim, Se-Dong;Rim, Seong-Jeong;Yoon, Yong-Han;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.513-515
    • /
    • 1997
  • The main purpose of this study was to develope the prototypes of on-line supervision system for maintenance to protect the confidence of operation of electric facilities in buildings. The influence of the harmonics on the electric facilities in building, which is recently growing more and more serious, were also analysed, and finally the essential techniques on the condition supervision, diagnosing method of facilities were proposed.

  • PDF

A Study on the Determination of Optimal Auto-reclosing (최적 재폐로방식 선정에 관한 연구)

  • Kim, Il-Dong;Han, Kyung-Nam;Rim, Seong-Jeong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.861-863
    • /
    • 1997
  • This paper presents a reliability and power quality taken account of the reclosing scheme on the power distribution system. To determine the optimal reclosing scheme, the simple radial distribution system is modelled, and analyzes quantitatively the effect of customer's load to the number of reclosing. The result of the analysis shows that the determined reclosing scheme can satisfy both the reliability and the power quality in the power distribution system.

  • PDF

Consideration of cable cross bonding and cable covering protection units (케이블 크로스본드 및 CCPU 적용검토)

  • Kim, Young;Kim, Jang-Woen;Seong, Jeong-Kue
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1646-1648
    • /
    • 1994
  • In the system of underground transmission line, the rate of electrical failure is very low, but, if once occuring, the failure evolves into a paralysis of the system, the time of restoration is very long, the damage from stopping of power supply is very serious, and the cost of restoration is very great. Because of these problems, you must try to protect the system and equipment from every electrical failure by contributing much carefulness to the design and operation of the underground system. This study summerizes the results of simmulation tests about the effect of installing this protection device on the insulated joint box and the terminal end box.

  • PDF

Development Research of Integration and Synchronization of Multi Sensors for Mobile Mapping System (모바일 매핑시스템을 위한 멀티 센서 통합 및 동기화 방안 연구)

  • 박영무;이종기;성정곤;김병국
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.167-172
    • /
    • 2004
  • 모바일 매핑시스템은 차량에 GPS(Global Positioning System), IMU(Inertial Measurement Unit), CCD 카메라 등을 탑재하고 공간 및 속성 정보를 취득하는 효율적인 방법이다. 모바일 매핑시스템은 도로 시설물 관리, 지도 갱신 등 다양한 분야에 이용되고 있다. 국외에서 개발된 모바일 매핑 시스템을 업그레이드하거나 새로운 센서를 추가 하고자 할 때 기존 시스템의 센서 통합 및 동기화 방안을 알 수 없으므로 시스템의 개선 및 향상이 어렵다. 본 연구에서는 모바일 매핑시스템의 개선 및 센서추가를 위해서 모바일 매핑시스템에 기본적으로 필요한 GPS, IMU, 그리고 CCD 카메라 등의 효율적인 통합 및 동기화 구현 방안을 제시하고, 동기화에 필요한 각 센서의 요구사항을 파악한 후 동기화 장비를 설계 및 제작하였다. 또한, 향후 추가될 센서인 레이져, 오도미터(Odometer) 등을 센서가 추가될 경우를 고려하여 통합장비를 설계하였다.

  • PDF

A Study about difference of GUI efficiency based on 3D and 2D Graphic (2D와 3D Graphic 기반으로 구성된 GUI의 효율성의 차이에 관한 연구)

  • Sung, Jung-Hwan;Lee, Dae-Young;Kim, Hyung-Koo
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02c
    • /
    • pp.164-169
    • /
    • 2007
  • 최근 영상 매체는 3D와 인터랙션분야를 중심으로 크게 발전하고 있다, 이는 3D 영상 구현을 위해 필요한 기술의 발전이 이루어지고 사용자에게 보다 높은 몰입감과 현실감을 주는 3D 그래픽의 장점 때문이다. 3D 영상 콘텐츠의 발전과 다양한 영상매체의 개발은 필연적으로 지금의 인터페이스구조의 변화와 혁신을 가지고 올 것이며 이는 2D 인터페이스가 가지고 있는 한계를 3D 인터페이스의 효율성으로 극복할 수 있을 것이다. 그 장점은 3D 인터페이스가 자율성(Autonomy), 상호작용성(Interaction), 현재성(Presence)의 특징을 구현할 수 있기 때문이다. 따라서 위와 같은 3D 인터페이스의 발전 가능성을 검증하기 위해 동일한 내용의 정보를 2D와 3D의 두 가지 인터페이스로 구현하여 비교해 본다.

  • PDF

Quantitative Evaluation of the Customers' Effect by Automatic Reclosing of Power Distribution System (배전시스템에서의 재폐로에 의한 수용가측 영향의 정량적 평가)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 1998
  • This paper presents an approach to quantitatively evaluate customers' effect due to automatic reclosing of power distribution systems. This proposed approach assess the customers' effect on equip ment halt by predicting a momentary interruption and voltage sag and analyzing the impact of customers' equipment sensitive to electric disturbances. Simulation results show that the increment of the number of reclosing improves the service reliability, but deteriorates the power quality for customers. The proposed approach utilizes the determination of automatic reclosing scheme and distribution system planning.anning.

  • PDF

A Study on the Diamond Thin Films Synthesized by Microwave Plasma Enhance Chemical Vapor Deposition (마이크로웨이브 플라즈마 화학기상성장법에 의한 다이아몬드 박막의 합성에 관한 연구)

  • 이병수;이상희;박상현;유동현;이백수;이덕출
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.809-814
    • /
    • 1998
  • In this study, the metastable state diamond thin films have been deposited on Si substrates from methand-hydrogen and oxygen mixture usin gMicrowave Plasma Enhanced Chemical Vapor Deposition (MWPCVD) method. effects experimental parameters MWPCVD including methan concentrations, oxygen additions, operating pressure, deposition time on the growth rate and crystallinity were investigated. diamond thin film was synthesized under the following conditions: methane concentration of 0.5%(0.5sccm)∼5%(5sccm). oxygen concentration of 0∼80%(2.4sccm). operating pressure of 30Torr∼ 70Torr, deposition time of 1∼32hr. SEM, WRD, and Raman spectroscopy were employed to analyse the growth rate and morphology, crystallinity and prefered growth direction, and relative amounts of diamond and non=diamond phases respectively.

  • PDF

Effects of an Overhead Ground Wire and Surge Arrester in the Railway due to Lightning Strokes (전차선로에서의 뇌격에 의한 가공지선과 피뢰기의 차폐효과)

  • Rim, Seong-Jeong;Han, Byung-Duk;Oh, Jung-Hwan;Yun, Sang-Yun;Kim, Jae-Chul;Chung, Yong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.468-470
    • /
    • 1999
  • Using the EMTP(Electro Magnetic Transient Program) for the analysis of lightning direct voltage on the railway system, the shielding effects of overhead grounding wire on the railway were studied quantitatively. Installation of overhead ground wire and sap-type arrester such as s-horn provides a 6.6kV HV distribution line with goof protection effects. Even severe lightning induced voltage were create, 6.6kV HV lines can be withstand.

  • PDF

New leakage detection system for the hydraulic system of EHV underground oil-filled cables (초고압 OF 케이블 급유계통의 조기이상검지시스템)

  • Kim, Y.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1966-1968
    • /
    • 2000
  • Globally, oil-filled paper-insulated cables and cross-linked polyethylene-insulated cables have been mainly applied for a underground power transmission line. The oil-filled cable has the hydraulic system in which insulating oil, expanded and contracted by temperature changes, is absorbed and supplied. This system enable us to detect oil leakages from the cable. But it has some problems such as difficulty in detecting minor leakages and a relatively long period of fault detecting. And so, this paper introduce a new leakage detection system, improved from the current one.

  • PDF