• Title/Summary/Keyword: 성능 회복

Search Result 400, Processing Time 0.027 seconds

A comparative study on the user satisfaction between two different piezoelectric engines (두가지 피에조 엔진의 사용자 만족도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Choi, So-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.269-277
    • /
    • 2017
  • Purpose: The aim of this study is to compare the performance of two piezoelectric engine systems by surveying satisfaction from dental clinicians. Materials and Methods: Two piezoelectric systems were evaluated: TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). For this study, 20 dentists responded to the 11 questionnaires in which 5 point Likert-type scale was used. The two devices were operated for 10 seconds and measured 5 times to compare the maximum noise values. In heat emission test, the handpiece was operated for 3 minutes and heat was measured at three positions each. Results: TRAUS XUS10 had higher satisfaction level on motor noise (P < 0.05). About function key and handpiece heat generation, PIEZOSURGERY touch showed higher satisfaction (P < 0.05) than TRAUS XUS10. The maximum noise level for each of the devices was confirmed to be 56.6 dB for the TRAUS XUS10 and 56.0 dB for PIEZOSURGERY touch. The two piezoelectric engines satisfied the safety standards with an operation temperature below $41^{\circ}C$ after having been operated for 3 minutes. Conclusion: Except for the function key and handpiece heat emission, TRAUS XUS10 has comparable performance with PIEZOSURGERY touch.

Correlation of Binder GPC Characteristics and Mechanical Properties of Hot-Mix Recycled Asphalt Mixtures (재생혼합물의 바인더 GPC특성과 역학적 특성과의 상관성 연구)

  • Kim, Kwang-Woo;Hong, Sang-Ki;Cho, Mun-Jin;Doh, Young-Soo
    • International Journal of Highway Engineering
    • /
    • v.7 no.1 s.23
    • /
    • pp.11-20
    • /
    • 2005
  • This study examined the correlation between mechanical properties and LMS(Large molecular size) of binders in hot-recycled asphalt mixtures. Hot-recycled asphalt mixtures were manufactured by various mixing methods. Laboratory tests including indirect tensile strength, wheel tracking test and Kim test were performed for each recycled mixture. Gel-permeation chromatography (GPC) analysis was performed for the binders coated on virgin and old (RAP) aggregates separately. For the purpose of binder aging analysis, a round-shaped virgin coarse aggregates (13mm gravel) were introduced in recycled mixtures. This makes possible to distinguish the virgin aggregates from RAP aggregates in recycled mixtures for GPC sampling. Results of GPC showed that there was significant difference in aging level between the binder coated on RAP and that of virgin aggregates in the same recycled mixture. Regression analysis was performed to correlate mechanical properties to LMS ratio. Results showed that most of the mechanical properties had relatively good correlation with LMS. This trend agree with LMS increase up to some degree, but fails for further LMS increase.

  • PDF

Surface Characteristics and Physical Properties of Cotton Fabric for Patient Clothing Material through a Chitosan/Nanosilver Colloidal Solution (환자복 소재용 면직물의 키토산/은나노 콜로이드용액 처리에 따른 표면 특성과 물리적 성질)

  • Jeong, Kyoung-Mi;Bae, Hyun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.12
    • /
    • pp.1873-1882
    • /
    • 2009
  • Hospital patient clothing material was treated with a mixture of chitosan in order to enhance functionality, such as the durability and dimensional stability of the cotton fabric used. Chitosan is a natural polymer with excellent biocompatibility, however there is a deteriorating adherence efficiency. The addition of a nanosilver colloidal solution in accordance with a prescribed ratio can further increase the performance of chitosan. Changes in the structural characteristics and physical properties of the chitosan/nanosilver treated fabric were observed in a comparison with fabric treated only with chitosan. The add-on ratio increased when the mixing ratio of nanosilver colloidal solution was higher; however, the crystalline structure of the treated fabric remains similar. In the case of CH3/NS1 treated fabric (where the mixing ratio of chitosan and nanosilver solution was 3:1) the K/S value, whiteness index, wet tensile strength, and wrinkle recovery angle were superior. The dimension stability, pilling resistance, and abrasion resistance of the fabric treated with a mixed solution increased in comparison to the fabric treated only with chitosan. The chitosan/nanosilver treated cotton fabric used for patient clothing material has excellent physical properties.

Design and Implementation of a High-Performance Index Manager in a Main Memory DBMS (주기억장치 DBMS를 위한 고성능 인덱스 관리자의 설계 및 구현)

  • Kim, Sang-Wook;Lee, Kyung-Tae;Choi, Wan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7B
    • /
    • pp.605-619
    • /
    • 2003
  • The main memory DBMS(MMDBMS) efficiently supports various database applications that require high performance since it employs main memory rather than disk as a primary storage. In this paper, we discuss the index manager of the Tachyon, a next-generation MMDBMS. Recently, the gap between the CPU processing and main memory access times is becoming much wider due to rapid advance of CPU technology. By devising data structures and algorithms that utilize the behavior of the cache in CPU, we are able to enhance the overall performance of MMDBMSs considerably. In this paper, we address the practical implementation issues and our solutions for them obtained in developing the cache-conscious index manager of the Tachyon. The main issues touched are (1) consideration of the cache behavior, (2) compact representation of the index entry and the index node, (3) support of variable-length keys, (4) support of multiple-attribute keys, (5) support of duplicated keys, (6) definition of the system catalog for indexes, (7) definition of external APIs, (8) concurrency control, and (9) backup and recovery. We also show the effectiveness of our approach through extensive experiments.

PCA 알고리즘과 개선된 퍼지 신경망을 이용한 여권 인식 및 얼굴 인증

  • Jung Byung-Hee;Park Choong-Shik;Kim Kwang-Baek
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2006.06a
    • /
    • pp.336-343
    • /
    • 2006
  • 본 논문에서는 여권 영 상에서 PCA 알고리즘을 이용한 얼굴 인증과 개선된 퍼지 신경망을 이용한 여권 코드 인식 방법을 제안한다. 본 논문에서는 여권영상에 대해 소벨 연산자를 이용하여 에지를 추출하고 에지가 추출된 영상을 수평 스미어링하여 여권코드 영역을 추출한다. 추출된 여권 코드 영역의 기울기를 검사하여 기울기 보정을 하고, 여권 코드 영역을 이진화 한다. 이진화된 여권 코드 영역에 대하여 8방향윤곽선 추적 알고리즘을 적용하여 여권 코드를 추출한다. 추출된 여권 코드는 퍼지 신경망을 개선하여 여권 코드 인식에 적용한다. 개선된 퍼지 신경 망은 입력층과 중간층 사이의 학습 구조로는 FCM 클러스터링 알고리즘을 적용하고 중간층과 출력층 사이의 학습은 일반화된 델타학습 방법을 적용한다. 그리고 학습 성능을 개선하기 위하여 중간층과 출력층의 가중치 조정에 적용되는 학습률을 동적으로 조정하기 위해 퍼지 제어 시스템을 적용한다. 제안된 퍼지 신경망은 목표값과 출력값의 차이에 대한 절대값이 ${\epsilon}$ 보다 적거나 같으면 정확으로 분류하고 크면 부정확으로 분류하여 정확의 총 개수를 퍼지 제어 시스템에 적용하여 학습률과 모멘텀을 동적으로 조정한다. 여권의 주어진 규격에 근거하여 사진 영역을 추출하고 추출된 사진 영역에 대하여 YCbCr와 RGB 정보를 이용하여 얼굴영역을 추출한다. 추출된 얼굴 영역을 PCA 알고리즘과 스냅샷(Snap-Shot) 방법을 적용하여 얼굴 영역의 위조를 판별한다. 제안된 방법의 여권 코드 인식과 얼굴 인증의 성능을 평가하기 위하여 실제 여권 영상에 적용한 결과, 기존의 방법보다 여권 코드 인식과 얼굴 인증에 있어서 효율적인 것을 확인하였다.s, whereas AVs provide much better security.크는 기준년도부터 2031년까지 5년 단위로 계획된 장래도로를 반영하여 구축된다. 교통주제도 및 교통분석용 네트워크는 국가교통DB구축사업을 통해 구축된 자료로서 교통체계효율화법 제9조의4에 따라 공공기관이 교통정책 및 계획수립 등에 활용할 수 있도록 제공하고 있다. 건설교통부의 승인절차를 거쳐 제공하며 활용 후에는 갱신자료 및 활용결과를 통보하는 과정을 거치도록 되어있다. 교통주제도는 국가의 교통정책결정과 관련분야의 기초자료로서 다양하게 활용되고 있으며, 특히 ITS 노드/링크 기본지도로 활용되는 등 교통 분야의 중요한 지리정보로서 구축되고 있다..20{\pm}0.37L$, 72시간에 $1.33{\pm}0.33L$로 유의한 차이를 보였으므로(F=6.153, P=0.004), 술 후 폐환기능 회복에 효과가 있다. 4) 실험군과 대조군의 수술 후 노력성 폐활량은 수술 후 72시간에서 실험군이 $1.90{\pm}0.61L$, 대조군이 $1.51{\pm}0.38L$로 유의한 차이를 보였다(t=2.620, P=0.013). 5) 실험군과 대조군의 수술 후 일초 노력성 호기량은 수술 후 24시간에서 $1.33{\pm}0.56L,\;1.00{\ge}0.28L$로 유의한 차이를 보였고(t=2.530, P=0.017), 술 후 72시간에서 $1.72{\pm}0.65L,\;1.33{\pm}0.3L$로 유의한 차이를 보였다(t=2.540, P=0.016). 6) 대상자의 술 후 폐환기능에 영향을 미치는 요인은 성별로 나타났다. 이에 따

  • PDF

Mycelial viability and cultivation characteristics of Hypsizygus marmoreus after long-term storage in different conditions (장기 저장 후 느티만가닥버섯(Hypsizygus marmoreus) 균주의 균사 생존력과 재배 특성에 대한 연구)

  • Lee, Hyae-Jung;Ro, Hyeon-Su;Kim, Jong-Guk;Lee, Chang-Yun
    • Journal of Mushroom
    • /
    • v.12 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • Mycelial viability and cultivation characteristics of strains of Hypsizygus marmoreus after long-term storage were investigated. The experimental conditions were the storage at $4^{\circ}C$ using a slant culture technique with or without mineral oil, and in liquid nitrogen tank in the presence of 10% glycerol or 10% glycerol with 5% trehalose. The myceila of four strains of H. marmoreus were thawed at 9, 21, 33, and 45 months after beginning of the storage, and then the growth of the mycelia was measured on a PDA plate with serial transfers to new plate for the recovery. The mycelial growth data after 45 months showed that the mycelia were mostly viable but not fully active particularly when they were stored in liquid nitrogen with 10% glycerol. The growth activity could be fully recovered after second transfer to new PDA plate. Cultivation of mushroom fruiting body using the recovered mycelia also demonstrated that the storage methods employed in this work were applicable for the long-term storage of H. marmoreus.

Implementation of Gait Analysis System Based on Inertial Sensors (관성센서 기반 보행 분석 시스템 구현)

  • Cho, J.S.;Kang, S.I.;Lee, K.H.;Jang, S.H.;Kim, I.Y.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait analysis system to measure and analyze lower-limb movements. We developed an integral AHRS(Attitude Heading Reference System) using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE(Root Mean Square Error) of 1.08 and 1.72 degree in yaw and pitch angle. In order to evaluate the performance of our the gait analysis system, we compared the joint angle for the hip, knee and ankle with those provided by Vicon system. The result shows that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limb or gait analysis during the post-stroke recovery.

  • PDF

Performance Enhancement Architecture for HLR System Based on Distributed Mobile Embedded System (분산 모바일 임베디드 시스템 기반의 새로운 위치정보 관리 시스템)

  • Kim Jang Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12B
    • /
    • pp.1022-1036
    • /
    • 2004
  • In mobile cellular network the ever-changing location of a mobile host necessitates the continuous tracking of its current position and efficient management of location information. A database called Home Location Register(HLR) plays a major role in location management in this distributed environment, providing table management, index management, and backup management facilities. The objectives of this paper are to identify the p개blems of the current HLR system through rigorous analysis, to suggest solutions to them, and to propose a new architecture for the HLR system. In the HLR system, a main memory database system is used to provide real-time accesses and updates of subscriber's information. Thus it is suggested that the improvement bemade to support better real-time facilities, to manage subscriber's information more reliably, and to accommodate more subscribers. In this paper, I propose an efficient backup method that takes into account the characteristics of HLR database transactions. The retrieval speed and the memory usage of the two-level index method are better than those of the T-tree index method. Insertion md deletion overhead of the chained bucket hashing method is less than that of modified linear hashing method. In the proposed backup method, I use two kinds of dirty flags in order to solve the performance degradation problem caused by frequent registration-location operations. Performance analysis has been performed to evaluate the proposed techniques based on a system with subscribers. The results show that, in comparison with the current techniques, the memory requirement is reduced by more than 62%,directory operations, and backup operation by more than 80%.

The Application of Octa-Substituted Metallophthalocyanine Langmuir-Blodgett films for $NO_2$ Measurement (수정진동자를 이용한 프탈로시아닌 LB박막의 $NO_2$ 감지 특성)

  • Kwon, H.J.;Lee, Y.J.;Chang, Y.K.;Kim, J.D.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.254-262
    • /
    • 1998
  • Multilayer Langmuir-Blodgett (LB) films coated on quartz crystal microbalance (QCM) of octa-substituted metallophhtalocyanines ($MPc(OEH)_8$, M = Cu, Co, and Sn) and dihydrogen phthalocyanines ($H_2Pc(OEH)_8$) were used to quantify $NO_2$ concentrations. They were exposed to various concentrations of $NO_2$ in dry $N_2$. Among the four phthalocyanines we tested, the metal-free $H_2Pc(OEH)_8$ was observed to be most sensitive to $NO_2$. However, its LB film showed a partially irreversible behavior, that is part of the frequency change due to $NO_2$ adsorption could not be recovered even after purging with pure $N_2$ gas for an extended period. Examining the spectra of NMR and FTIR revealed fact that the irreversible portion of frequency change was due to ether groups in the linkage between side chains and the Pc unit. In order to remove the effect of such initial deactivation, on $NO_2$ quantification experiment, a freshly fabricated LB film was treated at a high concentration of $NO_2$ so that the ether sites were saturated. A pretreated LB film showed a reproducible performance for repeated uses. The $CuPc(OEH)_8$ LB film showed a satisfactory sensing performance down to as low as 4 ppm. For the $H_2Pc(OEH)_8$ LB film, the lower detection limit was found to be 35ppb of $NO_2$. In order to make the experimental condition more realistic, the carrier gas, dry nitrogen, was replaced by air. It was observed that the presence of oxygen, a weak electron acceptor, reduced the sensitivity and thus increased the sensing limit to hundreds of ppb. Results of experiments with moisture added showed that the interference of moisture was quite severe.

  • PDF

Electrochemical Performance of Graphite/Silicon/Pitch Anode Composites Bonded with Graphite Surface PVP and Silica Amine Function Group (흑연 표면의 PVP와 실리카의 아민 작용기로 결합된 흑연/실리콘/피치 음극 복합소재의 전기화학적 성능)

  • Lee, Su Hyeon;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.118-123
    • /
    • 2019
  • In this study, the electrochemical characteristics of Graphite/Silicon/Pitch anode composites were analyzed to improve the low theoretical capacity of graphite as a lithium ion battery. The Graphite/Silica composites were synthesized by bonding silica onto polyvinylpyrrolidone coated graphite. The surface of used silica was treated with (3-Aminopropyl)triethoxysilane(APTES). Graphite/Silicon/Pitch composites were prepared by carbonization of petroleum pitch, the fabrication processes including the magnesiothermic reduction of nano silica to obtain silicon and varying the mass ratio of silica. The Graphite/Silicon/Pitch composites were analysed by XRD, SEM and XRD. Also the electrochemical performances of Graphite/Silicon/Pitch composite as the anode of lithium ion battery were investigated by constant current charge/discharge, rate performance, cyclic voltammetry and electrochemical impedance tests in the electrolyte of $LiPF_6$ dissolved in organic solvents (EC:DMC:EMC=1:1:1 vol%). The Graphite/Silicon/Pitch anode composite (silica 28.5 in weight) has better capacity (537 mAh/g). The cycle performance has an excellent capacity retention to 30th cycle of 95% and the retention rate capability of 98% in 0.1 C/0.2 C.