• 제목/요약/키워드: 성능제어

Search Result 9,046, Processing Time 0.05 seconds

A Study on Erosion Structure Properties for Thermal Insulation Materials on Carbon-Carbon Composites and Graphite Nozzle Throat (C-C 복합재료와 Graphite 노즐목 내열재의 침식조직 특성에 대한 연구)

  • Kim, Young In;Lee, Soo Yong
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.42-49
    • /
    • 2017
  • The solid rocket motor(SRM) consists of a motor case, igniter, propellants, nozzle, insulation, controller, and driving device. The liquid rocket propulsion systems(LRPSs) cools the nozzle by the fuel and oxidizer but SRM does not cool the nozzle. The nozzle of SRM is high temperature condition and high velocity condition so occurs the erosion by combustion gas. This erosion occurs the change of nozzle throat and reduces thrust performance of rocket. The material of Rocket nozzle is minimization of erosion and insulation effect and endure the shear force, high temperature and high pressure. The purpose of this study is to investigate the erosion characteristics of solid rocket nozzles by each combustion time. Through the structure inspection of Graphite and C-C composite, identify the characteristics of the microstructure before and after erosion.

Theoretical Performance Analysis between Attack Prevention Schemes and Attack Mitigation Schemes (공격차단 기법과 공격경감 기법 간 이론적 성능 분석)

  • Ko Kwang-Sun;Eom Young-Ik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.7 s.349
    • /
    • pp.84-92
    • /
    • 2006
  • To defeat abnormal traffic driven by DoS (Denial-of-Service) or DDoS (Distributed DoS), there has been a variety of researches or studies in a few decades. In this paper, we present the results of theoretical performance analysis between attack prevention schemes and attack mitigation schemes. The former is a scheme that prevents abnormal incoming traffic from forwarding into a specific network based on filtering rules, and the latter is a scheme that makes some perimeter or intermediate routers, which exist on the traffic forwarding path, prevent abnormal traffic based on their own abnormal traffic information, or that mitigates abnormal traffic by using quality-of-service mechanisms at the gateway of the target network. The aspects of theoretical performance analysis are defined as the transit rates of either normal traffic or false-positive traffic after an attack detection routine processes its job, and we also present the concrete network bandwidth rates to control incoming traffic.

A Design of Noise Reduction Circuit for A radio Telephonic System (무선전화 시스템용 잡음억제회로의 설계)

  • Moon, Jong-Kyu;Kim, Duk-Gyoo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.84-89
    • /
    • 2002
  • In this paper, we present the design method of noise reduction circuit in telephonic system. The circuit consists of compressor, expander and a filter. The basic idea of a proposed method compresses the audible signal in order to mask the channel noise during transmission and then expand at the reverse rate the transmitted signal to naturally recover the original signal. Of course, there should be no distortion or other degradation of the audio itself in passing through companding(compress/expand) cycle. In the compressing process, the gain of compressor is automatically controlled by the envelope level of input signal in order to increase the effective dynamic range of input signal and to improve the signal to noise ratio. The compressed rate is the root time of a audible signal. The compressed signal should be expanded at the square time of the signal to recover a original signal. Simulation shows the proposed method improves the performance of the noise reduction of a channel noise as well as stability. 

Dynamic Channel Allocation Algorithm for Co-channel Interference Avoidance in Multi-cell OFDMA Systems (OFDMA 다중 셀 환경에서 동일 채널 간섭을 피하기 위한 동적 자원 할당 알고리즘)

  • Lee, Je-Min;Seo, Woo-Hyun;Wang, Hano;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.5
    • /
    • pp.92-98
    • /
    • 2007
  • We propose the schemes for the dynamic channel allocation (DCA) in multi-cell OFDMA systems to avoid co-channel interference (CCI) without the additional complexity. The allocatable subcarriers areas, which is designed to avoid CCI among cells, are determined for each cell. Each cell allocates the subcarriers within the allocatable subcarriers area of the cell independently. We consider the trade off between the reduced frequency selection diversity and the amount of CCI on a subcarrier by the determination of allocatable subcarriers area. Hence, the equal allocation bound scheme for the high selectivity channel and the flexible allocation bound scheme for the low selectivity channel are proposed. Through the numerical results, it is confirmed that the proposed schemes have better performance in the aspects of the number of overlapping allocated subcarriers, the capacity and the outage probability compared to the case which does not determined the allocatable subcarriers area.

A Design of Current-mode Buck-Boost Converter using Multiple Switch with ESD Protection Devices (ESD 보호 소자를 탑재한 다중 스위치 전류모드 Buck-Boost Converter)

  • Kim, Kyung-Hwan;Lee, Byung-Suk;Kim, Dong-Su;Park, Won-Suk;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.330-338
    • /
    • 2011
  • In this paper, a current-mode buck-boost converter using Multiple switching devices is presented. The efficiency of the proposed converter is higher than that of conventional buck-boost converter. In order to improve the power efficiency at the high current level, the proposed converter is controlled with PWM(pulse width modulation) method. The converter has maximum output current 300mA, input voltage 3.3V, output voltage from 700mV to 12V, 1.5MHz oscillation frequency, and maximum efficiency 90%. Moreover, this paper proposes watchdog circuits in order to ensure the reliability and to improve the performance of dc-dc converters. An electrostatic discharge(ESD) protection circuit for deep submicron CMOS technology is presented. The proposed circuit has low triggering voltage using gate-substrate biasing techniques. Simulated result shows that the proposed ESD protection circuit has lower triggering voltage(4.1V) than that of conventional ggNMOS(8.2V).

A Ka-band 8-channel TX Active Module Design for Active Phased Array Antenna (능동위상배열 안테나를 위한 Ka-대역 8채널 송신능동모듈 설계)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.135-139
    • /
    • 2013
  • This paper presents the 8-channel active module operated in Ka-band. The module is designed for the mobile satellite communication antenna systems, and the module structure has the merit to minimize the size and weight of the antenna systems by 30% compared with the conventional systems using the active module composed of single channel. This module was designed to be optimally operated by prohibiting the electrical interference among the individual channels. From the test results of the fabricated 8-channel active module, it can be confirmed that the maximum channel gain error is ${\pm}1.3dB$, the minimum channel output power is 21.5dBm, and the maximum gain variation by phase control is ${\pm}1.0dB$.

Seismic Response Comparative Evaluation Study on Floor Isolation using LRB and FPS in Main Control Room of Nuclear Power Plant (LRB, FPS 지진격리시스템의 지진응답특성 비교연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.15-23
    • /
    • 2009
  • An experimental study was performed to evaluate seismic reduction performance and the applicability of 2-dimensional floor isolation system to the main control room of a nuclear power plant. A lead-rubber bearing (LRB) and a friction pendulum system (FPS) were designed and fabricated for a 2-dimensional floor isolation system. A partial experimental model of a main control room with the LRB and FPS was tested using a shaking table. The experimental model consisted of a control panel, a 2.5m${\times}$2.5m access floor, and four LRB and FPS. The artificial time histories based on the horizontal floor response spectrums (OBE, SSE) of the main control room were used as earthquake input signals. Compared to the non-isolated system, the seismic response of experimental models using a 2-dimensional floor isolation system showed considerable seismic reduction performance against an earthquake.

Learning of Fuzzy Rules Using Fuzzy Classifier System (퍼지 분류자 시스템을 이용한 퍼지 규칙의 학습)

  • Jeong, Chi-Seon;Sim, Gwi-Bo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.37 no.5
    • /
    • pp.1-10
    • /
    • 2000
  • In this paper, we propose a Fuzzy Classifier System(FCS) makes the classifier system be able to carry out the mapping from continuous inputs to outputs. The FCS is based on the fuzzy controller system combined with machine learning. Therefore the antecedent and consequent of a classifier in FCS are the same as those of a fuzzy rule. In this paper, the FCS modifies input message to fuzzified message and stores those in the message list. The FCS constructs rule-base through matching between messages of message list and classifiers of fuzzy classifier list. The FCS verifies the effectiveness of classifiers using Bucket Brigade algorithm. Also the FCS employs the Genetic Algorithms to generate new rules and modify rules when performance of the system needs to be improved. Then the FCS finds the set of the effective rules. We will verify the effectiveness of the poposed FCS by applying it to Autonomous Mobile Robot avoiding the obstacle and reaching the goal.

  • PDF

Nonuniform Delayless Subband Filter Structure with Tree-Structured Filter Bank (트리구조의 비균일한 대역폭을 갖는 Delayless 서브밴드 필터 구조)

  • 최창권;조병모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2001
  • Adaptive digital filters with long impulse response such as acoustic echo canceller and active noise controller suffer from slow convergence and computational burden. Subband techniques and multirate signal processing have been recently developed to improve the problem of computational complexity and slow convergence in conventional adaptive filter. Any FIR transfer function can be realized as a serial connection of interpolators followed by subfilters with a sparse impulse response. In this case, each interpolator which is related to the column vector of Hadamard matrix has band-pass magnitude response characteristics shifted uniformly. Subband technique using Hadamard transform and decimation of subband signal to reduce sampling rate are adapted to system modeling and acoustic noise cancellation In this paper, delayless subband structure with nonuniform bandwidth has been proposed to improve the performance of the convergence speed without aliasing due to decimation, where input signal is split into subband one using tree-structured filter bank, and the subband signal is decimated by a decimator to reduce the sampling rate in each channel, then subfilter with sparse impulse response is transformed to full band adaptive filter coefficient using Hadamard transform. It is shown by computer simulations that the proposed method can be adapted to general adaptive filtering.

  • PDF

Evaluation of Total Loss of Feedwater Accident/Recovery Phase and Investigation of the Associated EOP (완전급수상실사고/복구과정의 평가와 관련비상운전절차의 검토)

  • Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.37-50
    • /
    • 1993
  • To evaluate the sequence of event and the Thermohydraulic behavior during total loss of feedwater accident and recovery procedure, a RELAP5/MOD3 calculation is performed and compared with the LOFT L9-l/L3-3 experiment. Also, the predictability of the code for the major Thermohydraulic phenomena following the accident is assessed. As a result, it is found that a pressure control using the spray until the time the water level reaches the top of the pressurizer, an overpressure protection by pressurizer PORV, a recovery of the secondary heat removal capability by refilling steam generator, and an effective cooldown by the continued natural circulation can be performed without core uncovery. It is also found that the plant-specific evaluation is necessary to confirm the effectiveness of the current symptom-oriented emergency operating procedure, especially in an overpressure protection performance and steam generator recovery performance.

  • PDF