• Title/Summary/Keyword: 성능기반 내화설계

Search Result 26, Processing Time 0.032 seconds

A Study on Compressive Strength of Centrally-Loaded Steel Columns at Elevated Temperatures (중심축 하중을 받는 고온상태 강재기둥의 압축강도에 관한 연구)

  • Yoon, Jong Hwi;Lee, Chy Hyoung;Yoon, Sung Kee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.253-261
    • /
    • 2016
  • In order to evaluate compressive strength of centrally-loaded steel column at elevated temperature, new FE analysis techniques and assumptions of model were applied in this study. It also includes comparison with the existing studies, and a new design equation for centrally-loaded steel column at elevated temperature was proposed. The proposed equation was the most accurate of the three design equations(EC3, AISC, proposed equation) when comparing with the coefficient of determination on the simulated results and test results.

피복 두께에 따른 프리스트레스트 프리캐스트 콘크리트의 내화성능 예측

  • Min, Jeong-Gi;U, Yeong-Je;Choe, Yong-Muk;An, Byeong-Gwon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.4-5
    • /
    • 2013
  • 프리스트레스트된 프리캐스트 콘크리트 부재는 장경간이 가능하고 공장생산으로 품질관리가 용이하다. 그러나 프리스트레싱 텐던이 화재에 노출되는 경우 일반 철근에 비해 급격하게 강도를 상실해 구조물의 붕괴로 이어질 수 있다. 국내의 경우 실험에 기초한 내화성능에 대한 연구는 활발히 이루어지고 있으나 그에 반해 성능기반 설계법이 활성화 될 때 요구되는 수치해석적인 연구는 많이 부족한 실정이다. 따라서 본 연구에서는 문헌조사를 통해 이전에 수행된 실험 데이터를 통해 현재 외국에서 활발히 사용되는 수치해석 프로그램을 검증하고 수치해석 모델링을 통해 각각의 내화시간에 따른 적절한 피복 두께를 제안하였다.

  • PDF

A Study on the Design Fire Model for Structural Fire Resistant Design in Buildings (건축구조물의 구조내화설계를 위한 설계화재모델에 관한 연구)

  • Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.256-257
    • /
    • 2019
  • Recently, the fire risk of architectural structures is increasing due to the super high - rise and super - size of the buildings. Therefore, the direction of fire safety design tends to change from the existing design to the performance - based design. In particular, domestic fire safety policies are divided into building law and fire fighting law. In case of fire fighting law, performance design is already carried out. Therefore, this study summarizes the prediction formula for fire characteristics among the structural fireproofing design field as shown in Fig. 1 according to this situation, and compares it with the standard method of each country in particular.

  • PDF

An Experimental Study on Fire Resistance Performance of Asymmetric Slimfloor Beam (단면형상 변화에 따른 비대칭 H형강 합성플로어 내화성능변화에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hoon;Lee, Jea-Sung;Cho, Kyung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.7-8
    • /
    • 2010
  • The temperature development of a structural element is dependent on section factor, which is estimated as a ratio of the fire-exposed perimeter to the cross-section area. Hence, with the higher section factor, the faster temperature development of the section os observed. Composite beam member, partially embedded asymmetry H beam, has a good fire resistance to the cross-section. The study was intended to conduct with change with section factor. The experimental result of section type which the Slim Beam Floor is bottom flange reinforced method.

  • PDF

국부 화재에 노출된 강재 기둥의 거동 특성

  • Min, Jeong-Gi;Chae, Hak-Byeong;Kim, Tae-Sang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.31-32
    • /
    • 2013
  • 건축 구조물의 내화성을 판단하기 위한 가장 보편적인 방법은 가열로에서 규정된 표준가열곡선에 따라 시험하는 것이다. 이러한 방법은 건축 구조물의 내화성을 빠르고 쉽게 판단하기에는 적합하나 지식의 발전과 함께 증가하는 성능기반설계법에 대해 합리적인 근거를 제시하지 못하고 있다. 따라서 본 논문에서는 실제 화재에서 발생할 수 있는 국부화재에 대한 강재 기둥의 거동에 대해 평가하고 그에 대한 기초자료를 제시하고자 하였다.

  • PDF

Study on Fire Performance of Stud Connectors (스터드커넥터의 내화성능에 관한 연구)

  • Kim, Sung-Bae;Han, Sang-Hoon;Choi, Seng-Kwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2009
  • This research aims to conduct a pilot study for the in-fire performance of headed studs, commonly used in composite structures over the world. The robustness of the shear studs in fire appears to be a key element to govern the composite behaviour after a sudden local instability developed in structures such as trusses and cellular beams. In order to experimentally evaluate the residual strength of studs in fire, the standard push-out test was modified for a half of the original set-up to be equipped with a furnace. The adjustments allow the steel section to have a 3-sided exposure against fire. Under the Standard ISO fire, the modified push-out tests under loading were conducted to identify the failure mechanism of the studs in relation to temperature developments.