Browse > Article

Performance Based Structural Design of SC Composite Columns under Fire Condition  

Kang, S.D. (현대종합설계 구조설계팀)
Choi, J.S. (현대종합설계 구조설계팀)
Kim, I.G. (현대종합설계)
Publication Information
Computational Structural Engineering / v.24, no.4, 2011 , pp. 32-39 More about this Journal
Keywords
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chabot M, Lie TT. Experimental studies on the fire resistance of hollow steel columnsfilled with bar reinforced concrete. Institute for Research in Construction, National Research Council of Canada, Ottawa, Ont., IRC International Report No. 628; 1992.
2 Sakumoto Y, Okada T, Yoshida M, S. Tasaka S. Fire resistance of concrete filled fire resistance steel tube columns. Journal of Materials in Civil Engineering 1994; 6(2): 169-184.   DOI   ScienceOn
3 Lie TT. Fire resistance of circular steel columns filled with bar-reinforced concrete. ASCE Journal of Structural Engineering 1994; 120(5); 489-1509.
4 Kodur VKR, LieTT. Fire performance of concrete-filled hollow steel columns. Journal of Fire Protection Engineering 1995; 7(3); 9-98.
5 Kodur VKR, Lie TT. Experimental studies on the fire resistance of circular hollow steel columns filled with steel-fibre-reinforced concrete. Institute for Research in Construction, National Research Council of Canada, Ottawa, Ont., IRC International Report No. 691; 1995.
6 Chabot M, Lie TT. Experimental studies on the fire resistance of hollow steel columns filled with barreinforced concrete., Institute for Research in Construction, National Research Council of Canada, Ottawa, Ont., IRC International Report No. 628; 1992.
7 Lie TT, Chabot M. Experimental studies on the fire resistance of hollow steel columns filled with plain concrete. Institute for Research in Construction, National Research Council of Canada, Ottawa, Ont., IRC International Report No. 611; 1992.
8 Han LH, Yang YF, Xu L. (2003), An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns. Journal of Construct Steel Research 2003 59(4); 427-452.   DOI   ScienceOn
9 Lin-Hai Han, Jing-Si Huo (2003), Concrete-filled hollow structural steel columns after exposed to ISO-834 fire standard, Journal of Structural Engineering, Vol. 129, No. 1, pp. 68-78.   DOI   ScienceOn
10 Y. Sakumoto, T. Yamaguchi, T. Okada, M. Yoshida, S. Tasaka, H. Saito (1994), Fire resistance of fire-resistance steel columns, Journal of Structural Engineering, Volume 120, Issue 4, pp. 1103-1121.   DOI   ScienceOn
11 Lie TT, Chabot M. Experimental studies on the fire resistance of hollow steel columns filled with plain concrete. Institute for Research in Construction, National Research Council of Canada, Ottawa, Ont., IRC International Report No. 611; 1992.
12 Prion HGL, Baraka M. Thin-walled tubes filled with high strength concrete. Canadian Journal of Civil Engineering 1994; 21(1); 207-218.   DOI
13 T.T. Lie and V.K.R. Kodur (1996), Fire resistance of steel columns filled with bar-reinforced concrete, Journal of Structural Engineering, Volume 122, Issue 1, pp. 30-36.   DOI