• Title/Summary/Keyword: 성능감소

Search Result 7,601, Processing Time 0.037 seconds

Removal of Nitrogen Oxides Using Hydrocarbon Selective Catalytic Reduction Coupled with Plasma (플라즈마가 결합된 탄화수소 선택적 촉매환원 공정에서 질소산화물(NOx)의 저감)

  • Ihm, Tae Heon;Jo, Jin Oh;Hyun, Young Jin;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.27 no.1
    • /
    • pp.92-100
    • /
    • 2016
  • Low-temperature conversion of nitrogen oxides using plasma-assisted hydrocarbon selective catalytic reduction of (HC-SCR) was investigated. Plasma was created in the catalyst-packed bed so that it could directly interact with the catalyst. The effect of the reaction temperature, the shape of catalyst, the concentration of n-heptane as a reducing agent, the oxygen content, the water vapor content and the energy density on $NO_x$ removal was examined. $NO_x$ conversion efficiencies achieved with the plasma-catalytic hybrid process at a temperature of $250^{\circ}C$ and an specific energy input (SIE) of $42J\;L^{-1}$ were 83% and 69% for one-dimensional Ag catalyst ($Ag\;(nanowire)/{\gamma}-Al_2O_3$) and spherical Ag catalyst ($Ag\;(sphere)/{\gamma}-Al_2O_3$), respectively, whereas that obtained with the catalyst-alone was considerably lower (about 30%) even with $Ag\;(nanowire)/{\gamma}-Al_2O_3$ under the same condition. The enhanced catalytic activity towards $NO_x$ conversion in the presence of plasma can be explained by the formation of more reactive $NO_2$ species and partially oxidized hydrocarbon intermediates from the oxidation of NO and n-heptane under plasma discharge. Increasing the SIE tended to improve $NO_x$ conversion efficiency, and so did the increase in the n-heptane concentration; however, a further increase in the n-heptane concentration beyond $C_1/NO_x$ ratio of 5 did not improve the $NO_x$ conversion efficiency any more. The increase in the humidity affected negatively the $NO_x$ conversion efficiency, resulting in lowering the $NO_x$ conversion efficiency at the higher water vapor content, because water molecules competed with $NO_x$ species for the same active site. The $NO_x$ conversion efficiency increased with increasing the oxygen content from 3 to 15%, in particular at low SIE values, because the formation of $NO_2$ and partially oxidized hydrocarbon intermediates was facilitated.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Study of Prediction Model Improvement for Apple Soluble Solids Content Using a Ground-based Hyperspectral Scanner (지상용 초분광 스캐너를 활용한 사과의 당도예측 모델의 성능향상을 위한 연구)

  • Song, Ahram;Jeon, Woohyun;Kim, Yongil
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_1
    • /
    • pp.559-570
    • /
    • 2017
  • A partial least squares regression (PLSR) model was developed to map the internal soluble solids content (SSC) of apples using a ground-based hyperspectral scanner that could simultaneously acquire outdoor data and capture images of large quantities of apples. We evaluated the applicability of various preprocessing techniques to construct an optimal prediction model and calculated the optimal band through a variable importance in projection (VIP)score. From the 515 bands of hyperspectral images extracted at wavelengths of 360-1019 nm, 70 reflectance spectra of apples were extracted, and the SSC ($^{\circ}Brix$) was measured using a digital photometer. The optimal prediction model wasselected considering the root-mean-square error of cross-validation (RMSECV), root-mean-square error of prediction (RMSEP) and coefficient of determination of prediction $r_p^2$. As a result, multiplicative scatter correction (MSC)-based preprocessing methods were better than others. For example, when a combination of MSC and standard normal variate (SNV) was used, RMSECV and RMSEP were the lowest at 0.8551 and 0.8561 and $r_c^2$ and $r_p^2$ were the highest at 0.8533 and 0.6546; wavelength ranges of 360-380, 546-690, 760, 915, 931-939, 942, 953, 971, 978, 981, 988, and 992-1019 nm were most influential for SSC determination. The PLSR model with the spectral value of the corresponding region confirmed that the RMSEP decreased to 0.6841 and $r_p^2$ increased to 0.7795 as compared to the values of the entire wavelength band. In this study, we confirmed the feasibility of using a hyperspectral scanner image obtained from outdoors for the SSC measurement of apples. These results indicate that the application of field data and sensors could possibly expand in the future.

A Study on the Synthesis and Its Biodistribution of C-11 and F-18 Labelled Choline (C-11 및 F-18 표지 콜린의 합성과 체내동태에 관한 연구)

  • Yang, Seung-Dae;Kim, Sang-Wook;Suh, Yong-Sup;Chun, Kwon-Soo;Ahn, Soon-Hyuk;Hur, Min-Goo;Lim, Sang-Moo;Hong, Sung-Woon;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.185-191
    • /
    • 2001
  • Objectives: Recently, $[methyl-^{11}C]-({\beta}$-Hydroxyethyl)trimethylammonium ($[^{11}C]$choline) Has been discovered to be a very effective tracer in imaging various human tumors using positron omission tomography. Because of the short half-life of C-11, it is very difficult to use in a routine imaging procedure and needs a frequent synthesis of $[^{11}C]$choline. This can be supplemented by the substitution of $[^{11}C]$choline with $[methyl-^{18}F]$fluorocholine. Here, we would like to report ceil uptake and biodistribution of $[^{11}C]$choline and $[^{18}F]$fluorocholine as a basic study. Methods: $[^{11}C]$Choline was prepared by the treatment of $[^{11}C]CH_3I$ with N,N-dimethylaminoethanol and $[^{18}F]$fluorocholine was synthesized from reaction of $CH_2Br[^{18}F]F$ with N,N-dimethylaminoethanol. The radiochemical purity was checked by high performance liquid chromatography (HPLC). The blodistribution of $[^{11}C]$choline and $[^{18}F]$fluorocholine was determined in balb/c mouse at 5 min, 20 min, 40 min and 80 min. The cell uptake was measured using glioma (9L) and colon adenocarcinoma (SW620). Results: The radiochemical purity was more than 98% after purification. In the liver, uptake did not change over time; the uptake was 20%ID/g for $[^{11}C]$choline and 13%ID/g for $[^{18}F]$fluorocholine. In the kidney, radioactivity decreased over time; the uptake was 15%ID/g for $[^{11}C]$choline and 20%ID/g for $[^{18}F]$fluorocholine, 80 min post-injection. The cell uptake of $[^{11}C]$choline was 4.93% for glioma (9L) and 18.69% for colon adenocarcinoma (SW620). For $[^{18}F]$fluorocholine, 1.77% for glioma (9L) and 2.77% for colon adenocarcinoma (SW620). Conclusion: $[^{11}C]$Choline and $[^{18}F]$fluorocholine showed a different cell uptake tendency, depending on cancer cell line.

  • PDF

Anisotrpic radar crosshole tomography and its applications (이방성 레이다 시추공 토모그래피와 그 응용)

  • Kim Jung-Ho;Cho Seong-Jun;Yi Myeong-Jong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.21-36
    • /
    • 2005
  • Although the main geology of Korea consists of granite and gneiss, it Is not uncommon to encounter anisotropy Phenomena in crosshole radar tomography even when the basement is crystalline rock. To solve the anisotropy Problem, we have developed and continuously upgraded an anisotropic inversion algorithm assuming a heterogeneous elliptic anisotropy to reconstruct three kinds of tomograms: tomograms of maximum and minimum velocities, and of the direction of the symmetry axis. In this paper, we discuss the developed algorithm and introduce some case histories on the application of anisotropic radar tomography in Korea. The first two case histories were conducted for the construction of infrastructure, and their main objective was to locate cavities in limestone. The last two were performed In a granite and gneiss area. The anisotropy in the granite area was caused by fine fissures aligned in the same direction, while that in the gneiss and limestone area by the alignment of the constituent minerals. Through these case histories we showed that the anisotropic characteristic itself gives us additional important information for understanding the internal status of basement rock. In particular, the anisotropy ratio defined by the normalized difference between maximum and minimum velocities as well as the direction of maximum velocity are helpful to interpret the borehole radar tomogram.

  • PDF

An Empirical Analysis of the Effects of Startup' Activities of Preparatory Stage and Early Stage on Performance (창업기업의 준비 및 초기단계 활동들이 기업 성과에 미치는 영향에 관한 연구)

  • Yoon, Byeong seon;Seo, Young wook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.11 no.4
    • /
    • pp.1-15
    • /
    • 2016
  • Startups in Korea are experiencing for themselves the laws of survival through competition in the local and international market, and are performing active business movements based on these. Korea's economic growth rate is 2.6% due to the slump in the domestic demand and reduced exports brought by the MERSC incident in 2015. The Korea Development Institute has estimated the economic growth rate in 2016 to be around 3.0%. South Korea's economy is facing the crisis of low-growth solidification due to the decrease in economic growth, and it is forecasted that growth without employment and polarization will worsen. Startups in the high-tech industrial generation of a particular field wherein the market environment is rapidly changing must maintain a competitive advantage with the capabilities and functions exclusive to them. It is very important that they maintain a competitive edge by utilizing the capabilities exclusive to startup companies. Likewise, the accumulation of resources is also crucial in determining the success of a startup business. In a poor local startup ecosystem, majority of the startup companies are performing their business activities while striving for survival, rather than success. About 80% are struggling to survive and are failing to overcome the "Death Valley" faced 3-5 years after establishing the company. Since majority of the startups fail to achieve results during the initial stages of foundation, the importance of research on business activities and achievement during the early stages of establishment is being raised. In accordance to this, this research has performed an actual analysis on how the activities of startups during their preparation phase and early stages affect their achievements. A survey was done on the CEOs or executives (people in a position to make decisions) of local small and medium-sized enterprises that are considered start-ups, and 203 valid data were collected and analyzed. Results showed that the discoveries and utilized activities necessary for the businesses of startups have a significant impact on their achievement through the entrepreneur resources and external partners' cooperation; additionally, the related implications were discussed.

  • PDF

Effect of Attenuation Correction, Scatter Correction and Resolution Recovery on Diagnostic Performance of Quantitative Myocardial SPECT for Coronary Artery Disease (감쇠보정, 산란보정 및 해상도복원이 정량적 심근 SPECT의 관상동맥질환 진단성능에 미치는 효과)

  • Hwang, Kyung-Hoon;Lee, Dong-Soo;Paeng, Jin-Chul;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.5
    • /
    • pp.288-297
    • /
    • 2002
  • Purpose: Soft tissue attenuation and scattering are major methodological limitations of myocardial perfusion SPECT. To overcome these limitations, algorithms for attenuation, scatter correction and resolution recovery (ASCRR) is being developed, while quantitative myocardial SPECT has also become available. In this study, we investigated the efficacy of an ASCRR-corrected quantitative myocardial SPECT method for the diagnosis of coronary artery disease (CAD). Materials and Methods: Seventy-five patients (M:F=51:24, $61.0{\pm}8.9$ years old) suspected of CAD who underwent coronary angiography (CAG) within $7{\pm}12$ days of SPECT(Group-I) and 20 subjects (M:F=10:10, age $40.6{\pm}9.4$) with a low likelihood of coronary artery disease (Group-II) were enrolled. Tl-201 rest/ dipyridamole-stress Tc-99m-MIBI gated myocardial SPECT was performed. ASCRR correction was peformed using a Gd-153 line source and automatic software (Vantage-Pro; ADAC Labs, USA). Using a 20-segment model, segmental perfusion was automatically quantified on both the ASCRR-corrected and uncorrected images using an automatic quantifying software (AutoQUANT; ADAC Labs.). Using these quantified values, CAD was diagnosed in each of the 3 coronary arterial territories. The diagnostic performance of ASCRR-corrected SPECT was compared with that of non-corrected SPECT. Results: Among the 75 patients of Group-I, 9 patients had normal CAG while the remaining 66 patients had 155 arterial lesions; 61 left anterior descending (LAD), 48 left circumflex (LCX) and 46 right coronary (RCA) arterial lesions. For the LAD and LCX lesions, there was no significant difference in diagnostic performance. In Group-II patients, the overall normalcy rate improved but this improvement was not statistically significant (p=0.07). However, for RCA lesions, specificity improved significantly but sensitivity worsened significantly with ASCRR correction (both p<0.05). Overall accuracy was the same. Conclusion: The ASCRR correction did not improve diagnostic performance significantly although the diagnostic specificity for RCA lesions improved on quantitative myocardial SPECT. The clinical application of the ASC-RR correction requires more discretion regarding cost and efficacy.

Comparison of Characteristics on Electrolyzed Water Manufactured by Various Electrolytic Factors (전해인자에 따른 전기분해수의 특성 비교)

  • Kim, Myung-Ho;Jeong, Jin-Woong;Cho, Young-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.416-422
    • /
    • 2004
  • Efficacy of surface sterilization and physicochemical properties of electrolyzed water manufactured depending on electrolyte, materials, and type of electrolytic diaphragm used were investigated. Physical properties of electrolyzed water manufactured from diaphragm system showed the highest effectiveness under at distance between diaphragms of 1.0 mm and 20% NaCl supplying rate of 6 mL/min. ORP, HClO (should defined) content, and pH at above conditions were 1,170 mV, 100 ppm, and 2.5, respectively. Two-stage electrolyzed system was more effective than one-stage one. Electrolyzed water manufactured from non-diaphragm system at 4 mL/min supplying rate of 20% NaCl was similar to the most effective diaphragm system, whereas ORP, HClO content, and pH were 800 mV, 200 ppm, and 9, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORPs of 750 and 1,150 mV in non-diaphragm and diaphragm systems, respectively, and at HClO content of 100 ppm. Physicochemical properties of electrolyzed water manufactured from electrolytic diaphragm of $IrO_{2}$ and Pt+Ir were more effective than that of Pt. ORP and HClO contents of electrolyzed water manufactured from various electrolytes were high in order of NaCl>KCl>$CaCl_{2}$, whereas no differences were observed among electrolytes in sterilization efficacy. Twelve kinds of microorganisms tested (initial total count, $10^{5}-10^{6}CFU/mL$) were sterilized within 1-2 min by electrolyzed water.

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

Synthesis of Zeolite P1 and Analcime from Sewage Sludge Incinerator Fly Ash (하수슬러지 소각 비산재를 이용한 제올라이트 P1 및 Analcime의 합성)

  • Lee, Je-Seung;Chung, Sook-Nye;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.659-665
    • /
    • 2008
  • This study is about zeolite synthesis from the sewage sludge incinerator fly ash of "S" sewage treatment center located in Seoul. For this purpose, the properties of raw fly ash as starting material, the hydrothermal conditions for zeolite synthesis and the environmental applicabilities of synthesized zeolites were examined. Fly ash from sewage sludge incinerator has large quantities of SiO$_2$ and Al$_2$O$_3$ and their contents are 42.8 wt.% and 21.2 wt.% respectively. So fly ash is considered to be possible starting material for zeolite synthesis. The results from leaching test of fly ash showed that the concentration of hazardous metals were very low as compared with the Korea leaching standard of the Waste Management Law. But the concentration from total recoverable test of fly ash were higher than the fertilizer standard of Fertilizer Management Law. Major zeolite products synthesized by hydrothermal reaction are analcime in teflon vessel and zeolite P1 in borosilicate flask. Optimum conditions for the synthesis of analcime were 1 N of NaOH concentration, 16 hour of reaction time and 135$^{\circ}C$ of reaction temperature. For the zeolite P1 formation, the proper conditions were demonstrated to be 5 N of NaOH concentration, 16 hour reaction time and 130$^{\circ}C$ of reaction temperature in this study. Hazardous metal contents in the analcime product are similar with those in raw fly ash. In case of the zeolite P1, the contents are reduced to nearly a half. Raw fly ash and the analcime product showed NH$_4{^+}$ ion exchange capacity of 0$\sim$1.0 mg of NH$_4{^+}$g$^{-1}$ and 3.0$\sim$7.4 mg of NH$_4{^+}$g$^{-1}$, respectively. However, the zeolite P1 product reached exchange capacity to 14.6$\sim$17.8 mg of NH$_4{^+}$g$^{-1}$. This values are in the range of those of natural clinoptilolite and phillipsite. From this point of view, zeolite synthesis from sewage treatment sludge incinerator fly ash is a good alternative for solid waste recycling.