• Title/Summary/Keyword: 설치 오차

Search Result 665, Processing Time 0.025 seconds

Introduction of GOCI-II Atmospheric Correction Algorithm and Its Initial Validations (GOCI-II 대기보정 알고리즘의 소개 및 초기단계 검증 결과)

  • Ahn, Jae-Hyun;Kim, Kwang-Seok;Lee, Eun-Kyung;Bae, Su-Jung;Lee, Kyeong-Sang;Moon, Jeong-Eon;Han, Tai-Hyun;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1259-1268
    • /
    • 2021
  • The 2nd Geostationary Ocean Color Imager (GOCI-II) is the successor to the Geostationary Ocean Color Imager (GOCI), which employs one near-ultraviolet wavelength (380 nm) and eight visible wavelengths(412, 443, 490, 510, 555, 620, 660, 680 nm) and three near-infrared wavelengths(709, 745, 865 nm) to observe the marine environment in Northeast Asia, including the Korean Peninsula. However, the multispectral radiance image observed at satellite altitude includes both the water-leaving radiance and the atmospheric path radiance. Therefore, the atmospheric correction process to estimate the water-leaving radiance without the path radiance is essential for analyzing the ocean environment. This manuscript describes the GOCI-II standard atmospheric correction algorithm and its initial phase validation. The GOCI-II atmospheric correction method is theoretically based on the previous GOCI atmospheric correction, then partially improved for turbid water with the GOCI-II's two additional bands, i.e., 620 and 709 nm. The match-up showed an acceptable result, with the mean absolute percentage errors are fall within 5% in blue bands. It is supposed that part of the deviation over case-II waters arose from a lack of near-infrared vicarious calibration. We expect the GOCI-II atmospheric correction algorithm to be improved and updated regularly to the GOCI-II data processing system through continuous calibration and validation activities.

Verification of Kompsat-5 Sigma Naught Equation (다목적실용위성 5호 후방산란계수 방정식 검증)

  • Yang, Dochul;Jeong, Horyung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1457-1468
    • /
    • 2018
  • The sigma naught (${\sigma}^0$) equation is essential to calculate geo-physical properties from Synthetic Aperture Radar (SAR) images for the applications such as ground target identification,surface classification, sea wind speed calculation, and soil moisture estimation. In this paper, we are suggesting new Kompsat-5 (K5) Radar Cross Section (RCS) and ${\sigma}^0$ equations reflecting the final SAR processor update and absolute radiometric calibration in order to increase the application of K5 SAR images. Firstly, we analyzed the accuracy of the K5 RCS equation by using trihedral corner reflectors installed in the Kompsat calibration site in Mongolia. The average difference between the calculated values using RCS equation and the measured values with K5 SAR processor was about $0.2dBm^2$ for Spotlight and Stripmap imaging modes. In addition, the verification of the K5 ${\sigma}^0$ equation was carried out using the TerraSAR-X (TSX) and Sentinel-1A (S-1A) SAR images over Amazon rainforest, where the backscattering characteristics are not significantly affected by the seasonal change. The calculated ${\sigma}^0$ difference between K5 and TSX/S-1A was less than 0.6 dB. Considering the K5 absolute radiometric accuracy requirement, which is 2.0 dB ($1{\sigma}$), the average difference of $0.2dBm^2$ for RCS equation and the maximum difference of 0.6 dB for ${\sigma}^0$ equation show that the accuracies of the suggested equations are relatively high. In the future, the validity of the suggested RCS and ${\sigma}^0$ equations is expected to be verified through the application such as sea wind speed calculation, where quantitative analysis is possible.

Temperature Compensation of Optical FBG Sensors Embedded Tendon for Long-term Monitoring of Tension Force of Ground Anchor (광섬유 센서 내장형 텐던을 이용한 그라운드 앵커의 장기 장력모니터링을 위한 온도보상)

  • Sung, Hyun-Jong;Kim, Young-Sang;Kim, Jae-Min;Park, Gui-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.13-25
    • /
    • 2012
  • Ground anchor method is one of the most popular reinforcing technology for slope in Korea. For the health monitoring of slope which is reinforced by permanent anchor for a long period, monitoring of the tension force of ground anchor is very important. However, since electromechanical sensors such as strain gauge and V/W type load cell are also subject to long-term risk as well as suffering from noise during long distance transmission and immunity to electromagnetic interference (EMI), optical FBG sensors embedded tendon was developed to measure strain of 7-wire strand by embedding FBG sensor into the center king cable of 7-wire strand. This FBG sensors embedded tendon has been successfully applied to measuring the short-term anchor force. But to adopt this tendon to long-term monitoring, temperature compensation of the FBG sensors embedded tendon should be done. In this paper, we described how to compensate the effect in compliance with the change of underground temperature during long-term tension force monitoring of ground anchors by using optical fiber sensors (FBG: Fiber Bragg Grating). The model test was carried out to determine the temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon. The determined temperature sensitivity coefficient ${\beta}^{\prime}=2.0{\times}10^{-5}/^{\circ}C$ was verified by comparing the ground temperatures predicted from the proposed sensor using ${\beta}^{\prime}$ with ground temperatures measured from ground thermometer. Finally, temperature compensations were carried out based on ${\beta}^{\prime}$ value and ground temperature measurement from KMA for the tension force monitoring results of tension type and compression type anchors, which had been installed more than 1 year before at the test site. Temperature compensated tension forces are compared with those measured from conventional load cell during the same measuring time. Test results show that determined temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon is valid and proposed temperature compensation method is also appropriate from the fact that the temperature compensated tension forces are not dependent on the change of ground temperature and are consistent with the tension forces measured from the conventional load cell.

Measurement and Quality Control of MIROS Wave Radar Data at Dokdo (독도 MIROS Wave Radar를 이용한 파랑관측 및 품질관리)

  • Jun, Hyunjung;Min, Yongchim;Jeong, Jin-Yong;Do, Kideok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.2
    • /
    • pp.135-145
    • /
    • 2020
  • Wave observation is widely used to direct observation method for observing the water surface elevation using wave buoy or pressure gauge and remote-sensing wave observation method. The wave buoy and pressure gauge can produce high-quality wave data but have disadvantages of the high risk of damage and loss of the instrument, and high maintenance cost in the offshore area. On the other hand, remote observation method such as radar is easy to maintain by installing the equipment on the land, but the accuracy is somewhat lower than the direct observation method. This study investigates the data quality of MIROS Wave and Current Radar (MWR) installed at Dokdo and improve the data quality of remote wave observation data using the wave buoy (CWB) observation data operated by the Korea Meteorological Administration. We applied and developed the three types of wave data quality control; 1) the combined use (Optimal Filter) of the filter designed by MIROS (Reduce Noise Frequency, Phillips Check, Energy Level Check), 2) Spike Test Algorithm (Spike Test) developed by OOI (Ocean Observatories Initiative) and 3) a new filter (H-Ts QC) using the significant wave height-period relationship. As a result, the wave observation data of MWR using three quality control have some reliability about the significant wave height. On the other hand, there are still some errors in the significant wave period, so improvements are required. Also, since the wave observation data of MWR is different somewhat from the CWB data in high waves of over 3 m, further research such as collection and analysis of long-term remote wave observation data and filter development is necessary.

Creation of Actual CCTV Surveillance Map Using Point Cloud Acquired by Mobile Mapping System (MMS 점군 데이터를 이용한 CCTV의 실질적 감시영역 추출)

  • Choi, Wonjun;Park, Soyeon;Choi, Yoonjo;Hong, Seunghwan;Kim, Namhoon;Sohn, Hong-Gyoo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_3
    • /
    • pp.1361-1371
    • /
    • 2021
  • Among smart city services, the crime and disaster prevention sector accounted for the highest 24% in 2018. The most important platform for providing real-time situation information is CCTV (Closed-Circuit Television). Therefore, it is essential to create the actual CCTV surveillance coverage to maximize the usability of CCTV. However, the amount of CCTV installed in Korea exceeds one million units, including those operated by the local government, and manual identification of CCTV coverage is a time-consuming and inefficient process. This study proposed a method to efficiently construct CCTV's actual surveillance coverage and reduce the time required for the decision-maker to manage the situation. For this purpose, first, the exterior orientation parameters and focal lengths of the pre-installed CCTV cameras, which are difficult to access, were calculated using the point cloud data of the MMS (Mobile Mapping System), and the FOV (Field of View) was calculated accordingly. Second, using the FOV result calculated in the first step, CCTV's actual surveillance coverage area was constructed with 1 m, 2 m, 3 m, 5 m, and 10 m grid interval considering the occluded regions caused by the buildings. As a result of applying our approach to 5 CCTV images located in Uljin-gun, Gyeongsnagbuk-do the average re-projection error was about 9.31 pixels. The coordinate difference between calculated CCTV and location obtained from MMS was about 1.688 m on average. When the grid length was 3 m, the surveillance coverage calculated through our research matched the actual surveillance obtained from visual inspection with a minimum of 70.21% to a maximum of 93.82%.

Effect of Reversible Air-circulation Fans on Air Uniformity in a Cultivation Facility for Oyster Mushroom (느타리재배사 정역 제어 대류팬이 공기 균일도에 미치는 영향)

  • Yum, Sung Hyun;Kim, Si Hwan
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.383-392
    • /
    • 2021
  • It has been known that oyster mushrooms cultivated in facilities with thermal insulation have been strongly affected by inner environments. Forced air-circulation fans exert much direct influence on disturbing air inside the facility so the matter is of particular interest. This study is carried out to investigate the measured levels of air uniformity in a cultivation facility for oyster mushroom in the various cases that reversibly controlled air-circulation fans which drove the flow in the upward and reverse direction by turn and unidirectional fans by which the wind blew upwards only were operated from July 1 to 10. The actual survey for the selection of ongoing operation cases presented that farmers, even though there were some discrepancies, have made use of fans in a way that it paused for 5-30min after running for 5-15min by turn. The level of air uniformity in the case of adopting reversible fans revealed a slight difference of 1.4-1.8℃ (Temp.) and 7.8-8.7% (R.H.) under the condition of not using a cooler during the investigation period. By contrast, unidirectional fans showed a noticeable difference of 3.2-3.7℃ and 14.0-15.4%, which meant that air uniformity driven by reversible fans much more increased compared to that for unidirectional fans. Among the twenty operational applications considered for reversible fans, the circumstance that the wind blew upwards for 10-15min and ceased for 5-10min and blew again in the reverse direction for 10-15min in succession gave minor improvements at the level of air uniformity, but at present there was somewhat difficult to make decision on which cases were optimally best. It seems necessary that the effects of reversible fans on air uniformity as well as qualities of oyster mushrooms have to be appraised in the cultivation period and the flow visualization needs to be done to ascertain the performance of air mixture.

이온현미분석기를 사용한 남서부 경기육괴 변성암류의 U-Pb 저어콘 연대: 남중국지괴와의 대비 가능성

  • 조문섭
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2001.06a
    • /
    • pp.141-142
    • /
    • 2001
  • 남서부 경기육괴의 편마암류로부터 분리된 저어콘(zircon) 입자를 대상으로, 이온현미분석기(ion microprobe)를 사용한 U-Pb 연대를 구하였다. 그 결과는 후기 원생대(약 820 Ma) 뿐만 아니라 오르도비스기에 상당한 화성활동이 한반도에 있었음을 지시한다. 우리 나라 후기 원생대의 화성-변성 활동에 대해 알려져 있는 바는 극히 제한적이어서 후속연구가 필수적이며, 이러한 연구는 한반도의 지체구조적 변천사를 로디니아 초대륙(Rodinia supercontinent)의 생성-분리와 관련해 재조명할 수 있는 기회를 제공할 것이다. 또한 오르도비스기의 화성작용은 그동안 논란이 되어 왔던 소위 “칼레도니아(Caledonian)” 변동 (cf. 조문섭, 2000)에 대한 또 다른 증거를 제공해준다. 저어콘의 연대측정은 서호주의 커튼공업대학교에 설치되어 있는 SHRIMP-II(Sensitive High-Resolution Ion Microprobe-II; 고감도-고분해능 이온현미분석기)를 사용하였으며, 시료 준비 및 분석방법은 기존에 보고된 바와 같다 (e.g., Kinny et al., 1999). 분석된 3개의 암석 시료(1006-5, 8, 9)는 경기육괴의 남서부에 위치한 홍성 지역의 정편마암들이다. 1006-8 시료는 Turek and Kim (1996)이 전통적인 방법을 사용해 687$\pm$5 Ma의 U-Pb 저어콘 연대를 보고한 바 있는 화강암질 편마암 (시료번호, KJ43)에 해당된다. 두 개의 다른 시료는 1006-8 주변에서 산출하는 전형적인 경기육괴의 편마암류로서 화강암질 정편마암이다. 이들 시료로부터 분리된 저어콘 입자들은 대부분 화성기원의 누대구조와 자형의 결정형태를 보여준다. 과성장띠(overgrouth rims)는 1006-5 시료에서 흔하게, 그리고 1006-9 시료에서 매우 드물게 관찰된다. 음극선발광(cathodoluminescence) 영상의 해석을 통해 저어콘 결정의 성장사를 유추하였으며, 이를 바탕으로 이온현미분석 점(spot)을 정하였다. U-Pb-Th 자료는 퍼스(Perth) 저어콘 스탠다드 (CZ3, 564 Ma, $^{206}$Pb/$^{238}$U=0.0914)를 사용하였다. 아래에 기술하는 연대는 모두 $^{206}$Pb/$^{238}$U 연대에 해당된다. 두 개의 화강암질 편마암 시료로부터 구한 U-Pb 저어콘 연대는 각각 812 $\pm$ 14 Ma(1006-8)와 822 $\pm$ 17 Ma(1006-9)로 분석오차 내에서 서로 일치한다. 이 결과는 춘천 및 전곡 지역의 석류석 각섬암에서 보고된 Sm-Nd 전암연대(852 $\pm$ 24 Ma 및 824 $\pm$ 143 Ma; Lee and Cho, 1995; Ree et al., 1996)와 잘 부합한다. 따라서 후기 원생대 기간 중 화성활동이 한반도에서 광범위하게 일어났음을 시사한다. 한편, 1006-9 시료에서는 예외적으로 한 개의 저어콘 입자 주변부(rim)에서 매우 얇은 과성장띠가 관찰되었으며, 두 개의 점 분석으로부터 구한 U-Pb 저어콘 연대는 약 235 Ma이다. 이 띠는 또한 변성기원의 저어콘에서 흔히 관찰되는 작은 W (<0.05) 비를 보인다. 1006-5 시료는 위 두 시료로부터 수 km 떨어진 지점에서 채집하였으나, 저어콘 연대는 상이한 기록을 보여준다. 즉 매우 작은 Th/U (<0.01) 값을 갖는 저어콘의 주변부에서 223 $\pm$ 5 Ma의 연대가 잘 정의되며, 이는 1006-9 시료에서 관찰된 결과와 함께 트라이아스기의 고온변성작용이 백립암상에 가까운, 매우 높은 온도에 달하였음을 지시한다. 한편 저어콘의 중심부는 335-473 Ma의 비교적 넓은 연대 분포를 보인다. 이는 저어콘이 실제 성장한 연대를 지시하기보다는 트라이아스기의 변성작용에 따른 납손실(Pb loss) 그리고 누대 규모보다 더 큰 빔 크기(beam size, 약 30 $\mu\textrm{m}$)의 영향일 것으로 해석된다. 또한 저어콘이 다양한 외래물질로부터 기원했다는 증거가 관찰되지 않으므로, 이 정편마암의 모암은 오르도비스기(약 430-470 Ma)에 관입하였을 것으로 생각된다. 따라서 그동안 논란이 되어 왔던 소위 “칼레도니아” 변동이 한반도 내에 실존하였을 가능성을 시사한다. 이상의 결과를 종합하여 볼 때, 경기육괴의 변성암류는 후기 원생대 이후 다양한 저어콘의 성장사를 기록하고 있음을 알 수 있다: 즉 (1) 후기원생대(약 820 Ma)의 화성작용; (2) 오르도비스기(약 450 Ma)의 화성작용: 그리고 (3) 트라이아스기 (약 223 Ma)의 부분용융을 수반한 고온 변성작용으로 대표된다. 이러한 지질연대는, 옥천변성대에서 얻어진 756 Ma의 저어콘 연대(Lee et al., 1998)와 더불어, 친링-다비-수루(Qinling-Dabie-Sulu) 대륙 충돌대와 양쯔 지괴에서 보고된 지질연대 결과와 잘 부합한다. 따라서 지구연대학적으로 경기육괴가 북중국보다는 대륙충돌대를 포함하는 남중국지괴에 속할 것으로 결론지을 수 있다.

  • PDF

Nutrient Composition of Benthic Diatom Cultured on Plate at Four Areas in Spring (봄철 해역별 파판배양 부착규조류의 영양성분)

  • 김해영;허성범
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.143-144
    • /
    • 2003
  • 봄철 해역에 따른 부착미세조류의 영양성분 변화를 알아보기 위하여 본 실험을 수행하였다. 실험은 울진, 부안, 완도, 부산 지역에서 봄철인 2~4월 동안 실시되었으며 실험간의 오차를 줄이기 위해 실험 시작일의 차이는 최대 10일 이내로 하였다. 배양을 위한 실험해역의 기초 조사로 배양지역 연안해수의 수온, 염분, pH, 총질소, 총인, Chlorophyll-a의 측정을 하였고 각 지역의 부착미세조류를 수확하여 영양분석을 하였다. 실험에 사용된 파판은 전복 종묘생산에 이용되는 규조배양용 파판과 틀을 이용하였고 실험기간은 총 8주 동안 실시하였다. 2주마다 파판을 수거한 뒤 부착된 미세조류를 부드러운 솔로 분리하여 원심 분리한 후 지방산과 아미노산의 측정을 하였다. 또 각 시료의 일정량을 Sedwick-rafter counting chamber를 이용하여 검경ㆍ계수한 후 이를 단위면적당 개체수(cells/$\textrm{cm}^2$)로 환산하여 biomass를 구하였다. 봄철 지역간의 수온의 범위는 13.9~16.6$^{\circ}C$를 보였으며 울진이 가장 높고 부안지역이 가장 낮았다. 염분은 부안지역의 염분이 평균 2$\textperthousand$ 이상 낮았으며 그 외의 지역은 큰 차이가 없었다. pH는 7.77~8.21의 범위를 보이고 있었으며 질산염 농토는 부산이 0.265mg/$\ell$로 최대값을 보였고 울진이 0.032mg/$\ell$로 제일 낮았다. 인산염 농도는 완도지역이 0.018mg/$\ell$로 최대치를 보였고 부안은 검출되지 않았다. Chlorophyll-a의 농도는 울진지역이 0.66mg/$\ell$으로 제일 낮았으며 부산이 2.69mg/$\ell$, 부안지역이 2.27mg/$\ell$ 로 높은 값을 보였다. 봄철 지역에 따른 부착미세조류의 아미노산 분석결과는 울진이 실험지역 중 제일 높은 총 아미노산과 필수아미노산의 함량을 나타냈으며 각 지역별로 울진은 4주에 20.3%, 부안은 8주째 8.1%, 완도는 8주째 4.7%, 부산은 6주째 10.4%로 서로다른 시기에 높은 아미노산의 함량을 나타냈다. 실험지역 부착미세조류의 지방산 결과를 보면 전 실험기간동안 지방산 중 대부분은 $C_{18}$이하의 포화 또는 불포화 지방산이 주를 이루고 있었으며 palmitic acid( $C_{16:0}$)와 palmitoleic acid( $C_{16:0}$)의 양이 전체 지방산 함량중 37.47~75.94%로 대부분을 차지하고 있었다. 그리고 n-3HUFA(high unsaturated fat쇼 acids)인 EPA는 부안지역이 2주째 20.85%로 전체 지역중 함량이 제일 높았고, 울진은 실험기간중 6주가 14.76%로 제일 높은 함량을 보였다. 완도는 6주에만 10.97%의 함량을 보였으며 부산지역의 시료에서는 EPA의 검출이 없었다. 봄철 각지역에 설치된 파판에서의 부착미세조류 출현량을 보면 2주째의 부착미세조류량은 부안이 8.3$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 높았고 부산이 0.6$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 낮았다. 울진의 경우 0.7$\times$$10^3$ cells/$\textrm{cm}^2$로 부산과 비슷하게 낮은 출현량을 보였고 완도는 2.4$\times$$10^3$ cells/$\textrm{cm}^2$였다. 4주째의 출현량은 울진지역이 471.1$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 높았으며 부안, 완도, 부산 순으로 출현량이 낮았고 특히 부산은 1.2$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 낮았다. 6주째의 출현량은 울진 지역이 368.6$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 높았으며 부안 89.8$\times$$10^3$ cells/$\textrm{cm}^2$, 완도 25.1$\times$$10^3$ cells/$\textrm{cm}^2$, 부산 5.9$\times$$10^3$ cells/$\textrm{cm}^2$ 순이었다. 8주째의 경우에도 울진, 부안, 완도, 부산이 각각 255.8$\times$$10^3$ cells/$\textrm{cm}^2$, 157.8$\times$$10^3$ cells/$\textrm{cm}^2$, 44.3$\times$$10^3$ cells/$\textrm{cm}^2$, 1.1$\times$$10^3$ cells/$\textrm{cm}^2$로 4주, 6주의 경우와 같은 경향을 보였다.보였다.

  • PDF

A Development of Traffic Queue Length Measuring Algorithm Using ILD(Inductive Loop Detector) Based on COSMOS (실시간 신호제어시스템의 대기길이 추정 알고리즘 개발)

  • seong ki-ju;Lee choul-ki;Jeong Jun-ha;Lee young-in;Park dae-hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.85-96
    • /
    • 2004
  • The study begin with a basic concept, if the occupancy length of vehicle detector is directly proportional to the delay of vehicle. That is, it analogize vehicle's delay of a occupancy time. The results of a study was far superior in the estimation of a queue length. It is a very good points the operator is not necessary to optimize s1, s2, Thdoc. Thdoc(critical congestion degree) replaced 0.7 with 0.2 - 0.3. But, if vehicles have been experience in delay was not occupy vehicle detector, the study is in existence some problems. In conclusion, it is necessary that stretch queue detector or install paired queue detector. Also I want to be made steady progress a following study relation to this study, because it is required traffic signal control on congestion.

  • PDF

Biomass, Net Production and Nutrient Distribution of Bamboo Phyllostachys Stands in Korea (왕대속(屬) 대나무림(林)의 물질생산(物質生産) 및 무기영양물(無機營養物) 분배(分配)에 관한 연구(硏究))

  • Park, In Hyeop;Ryu, Suk Bong
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.3
    • /
    • pp.453-461
    • /
    • 1996
  • Three Phyllostachys stands of P. pubescens, P. bambusoides and P. nigra var, henonis in Sunchon were studied to investigate biomass, net production and nutrient distribution. Five $10m{\times}10m$ quadrats were set up and 20 sample culms of 2 years and over were harvested for dimension analysis in each stand. One year old culms and subterranean parts were estimated by the harvested quadrat method. The largest mean DBH, height and basal area were shown in P. pubescens stand, and followed by P. nigra var. henonis stand and P. bambusoides stand. There was little difference in accuracy among three allometric biomass regression models of logWt=A+B1ogD, $logWt=A+BlogD^2H$ and logWt=A+BlogD+ClogH, where Wt, D and H were dry weight, DBH and height, respectively. Analysis of covariance showed that there were significant differences in intercept among the linear allometric biomass regressons of three Phyllostachys species. Biomass included subterranean parts was the largest in P. pubescens stand(103.621t/ha), and followed by P. nigra var. henonis stand(86.447t/ha) and P. bambusoides stand(36.767t/ha). Leaf biomass was 6.3% to 7.8% of total biomass in each stands. The ratio of aboveground biomass and subterranean biomass in each stand was 1.87 to 2.26. Net production included subterranean parts was the greatest in P. pubescens stand(6.115t/ha/yr), and followed by P. nigra var. henonis stand(5.609t/ha/yr) and P, bambusoides stand(3.252t/ha/yr). The highest net assimilation ratio was estimated in P. pubescens stand(2.979), and followed by P. nigra var. henonis stand(2.752) and P. bambusoides stand(2.187). Biomass accumulation ratio of each stand was 2.679 to 5.358. Concentrations of N, P and Mg were the highest in leaves, and followed by subterranean parts, and culms+branches in all three species. Concentration of Ca was the highest in leaves, and followed by culms+branches, and subterranean parts in all three species. The difference in biomass among three species stands was caused by their culm size, leaf biomass, net assimilation ratio, and efficiency of leaves to produce culms.

  • PDF