퍼지로직 과열도 재설정 알고리즘을 사용한 멀티형 냉방시스템의 전자팽창밸브 제어 (The EEV Control of the Multi-type Air-conditioning System by using a Fuzzy Logic Superheat Temperature Setpoint Reset Algorithm)

  • 한도영;이상원
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.382-388
    • /
    • 2003
  • Refrigerant flow rates of the multi-type air-conditioning system can be regulated by electronic expansion valves (EEV). The performance of the multi-type air-conditioning system may be improved by lowering the superheat at the compressor suction side. In this study, a superheat temperature setpoint reset algorithm was developed by using fuzzy logics, and a PI algorithm was applied to control the superheat temperature near setpoints. Experimental results showed energy savings and stable operations at a multi-type air-conditioning system. Therefore, the developed setpoint reset algorithm may be effectively used for the EEV superheat temperature control of the multi-type air-conditioning system.

야간온도 변화에 따른 망고 'Irwin'의 개화, 과실특성 및 수체생육 (Flowering, Fruit Characteristic and Shoot Growth of the Mango, cv. 'Irwin' in Response to D ifferent Night Temperature)

  • 임찬규;안현주;전미경;김설아;정선우
    • 한국농림기상학회지
    • /
    • 제23권4호
    • /
    • pp.349-355
    • /
    • 2021
  • 본 연구는 꽃눈발아기부터 과실비대기까지 야간온도의 조정이 망고 'Irwin' 품종의 개화, 과실특성 및 수체생육에 미치는 영향을 조사함으로써 망고 재배를 위한 적정 야간온도를 구명하고 시설하우스 내부의 온도관리 방안을 모색하고자 수행하였다. 야간온도 처리에 따른 개화기, 만개기, 착과기, 성숙기 그리고 수확기는 온도가 높을수록 빨라지는 경향을 보였다. 꽃대길이는 야간온도가 10℃일때 가장 짧았으며 온도가 높을수록 생육이 좋아졌으나 15℃와 20℃의 처리간에는 유의차는 없었다. 과실 종경과 무게는 야간온도가 15℃와 20℃가 10℃보다 높게 나타났으며 가용성고형물함량(SSC)와 산함량(TA)은 야간온도 처리간에 차이를 보이지 않았다. 그리고 과실의 경도와 과피의 색도는 야간온도가 높을수록 높게 나타났다. 과실 수확이 끝나고 전정을 한 이후 발생한 가지의 생육은 처리간 유의차를 보이지 않았다. 따라서 망고의 시설하우스 재배 시 과실의 수량을 높이고 고품질 과실을 생산하기 위해서는 야간 최저온도를 15℃ 또는 20℃로 설정하는 것이 적절하며 난방비 절감을 위해서는 야간 최저온도를 15℃로 설정하여 재배하는 것이 바람직한 것으로 판단된다.

금형온도제어에 대한 실천공학모형 연구 (A Study on Practical Engineering Model for Tool Temperature Control)

  • 신주경
    • 실천공학교육논문지
    • /
    • 제10권2호
    • /
    • pp.89-94
    • /
    • 2018
  • 사출 성형에서 금형 온도는 성형품의 품질에 큰 영향을 준다. 어느 정도의 온도가 적정한가는 성형 재료, 성형품에서 요구되는 품질에 의해서 결정되고 중요한 것은 그 온도가 안정적이어야 한다. 먼저 그 수지에 적합한 금형 온도 조건 범위 내에서 성형품이 요구하는 품질에 맞는 금형 온도를 설정해야 한다. 즉, 성형품의 표면 광택, 성형 사이클의 단축, 변형 방지, 수축 및 수지 흐름의 용이성 등의 중요성에 의해서 금형 온도는 변화한다. 실질적인 금형 기술 향상을 위해서 사출 금형을 설계하고 제작하는 산업체에서 적용할 수 있는 온도 제어에 대한 애로 기술 과정의 훈련 모형을 제시하고자 한다.

틸팅열차 주변압기 냉각시스템의 온도설정알고리즘 (Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer)

  • 한도영;노희전;원재영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

발전소 과도상태 지능형 감시시스템 개발

  • 김종석;정일석
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.783-788
    • /
    • 1998
  • 발전소 운영자는 운전 시작시점에서 수명 종료시점까지 발전소 과도상태 종류별 횟수가 설계 제한치를 넘지 않도록 감시하여야 하며 이를 위해서는 발전소 운전 과도상태 기록유지가 필요하다. 그러나 현재와 같은 발전소 운전 Strip Chart나 Log Sheet를 이용하는 방식으로는 과도상태 발생여부 판단이 어려울 뿐만 아니라 카운팅 자체에도 많은 시간이 소요되어 좀더 편리한 방법의 도입이 필요하다. 본 연구에서는 발전소 주전산기의 운전 데이타를 이용한 과도상태 데이터 수집 및 지능형 과도상태 판단방법을 개발하여 시범 적용하였다. 과도상태 데이터 수집은 전송되는 데이터와 이전 데이터를 비교하여 변화가 있을 시에만 데이터 압축방식을 이용하여 저장하였고, 최대/최소온도, 최대/최소압력, 온도/압력기울기 등의 운전 데이타를 기 설정된 과도상태의 전체 변수와 비교하여 오차율 범위내에 들면 동일한 과도상태로 판단하였다. 원자로 냉각재 계통의 온도 및 압력과 같이 계기 오차가 비교적 작은($\pm$1$^{\circ}C$) 운전변수는 과도상태 판단이 용이하나 오차가 큰 운전변수의 경우에는 과도상태 판단을 위한 보다 상세한 알고리즘의 개발이 필요하다.

  • PDF

온도규격 설정을 위한 동아시아 온도 분석연구 (A Temperature Analysis Study of East Asia for Generation of Temperature Specification)

  • 김인수;강치우
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.11-22
    • /
    • 2002
  • In this paper, a statistical meaning that the 1% frequency value which is used as a basis for the temperature specification generation for weapon systems is similar to $3{\sigma}$ frequency value of a year is presented, and the theoretical reference for temperature specification generation is made. The new method which extracts the 1% frequency value from general weather data, not depending on long term temperature hour data, is established, and the temperature analysis result of East Asia is also presented by using this method. On the basis of these result, operational temperature for the weapon systems to be used in the area of East Asia is recommended.

TRIAC ON/OFF를 통한 4kW급 발열유리 온도 제어 시스템 (Heated-Glass Temperature Control System by using TRIAC ON/OFF Method)

  • 이수형;이창열;김인동;노의철;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.238-239
    • /
    • 2011
  • 겨울철이나 추운지역에서는 선박용 및 건축용의 창유리에 결로, 결빙현상이 쉽게 발생하고 쾌적한 시야확보 및 청결유지를 방해한다. 이를 방지하기 위해 발열유리 온도제어 시스템을 사용한다. 기존의 아날로그 발열유리 시스템은 정확한 온도설정, 상태표시 및 고장검지가 어렵다. 또한 통신에 의한 중앙제어가 어렵다. 이와 같은 기존시스템의 단점을 해결하기위해 본 논문에서는 마이크로프로세서에 의한 TRIAC제어를 이용하여 4[kW]급 발열유리의 온도제어 시스템을 설계한다. 그리고 실험을 통해 그 성능을 확인하고자 한다.