• Title/Summary/Keyword: 설비이용률

Search Result 198, Processing Time 0.039 seconds

Improved Phase-shift Pulse-width Modulation Full-bridge Converter using a Blocking Capacitor (블로킹커패시터를 이용한 향상된 위상천이 펄스폭변조 풀브리지 컨버터)

  • Jeong, Gang-Youl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.20-29
    • /
    • 2011
  • This paper presents an improved phase-shift pulse-width modulation (PWM) full-bridge converter using a blocking capacitor. As the proposed converter reduces the circulation energy by inserting only one series blocking capacitor at the primary side of the conventional phase-shift PWM full-bridge converter structure, it improves the operation characteristics of the conventional converter. In this paper, first, the operation of conventional phase-shift PWM full-bridge converter is roughly reviewed, and then the operational principle of the proposed converter is classified and explained by each mode. After that, a prototype design example based on the operational principle is shown. Then, the improved operation characteristics of the proposed converter are actually verified through the experimental results.

High-linearity enhancement of optical transmitter using optoelectronic predistortion method (광전자 프리디스토션 기법을 적용한 광 송신기의 높은 선형성 향상 특성)

  • Lee, Tae-Kyeong;Moon, Yon-Tae;Choi, Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.296-299
    • /
    • 2008
  • 최근 통신시스템과 핸드폰, PDA등의 통신기기들의 발전에 따라 사용자들은 높은 데이터 전송률과 고속의 통신서비스를 요구하고 있다. 이러한 상황에서 유 무선 통합 시스템인 Radio-over-Fiber(RoF) 시스템은 그 대안으로 대두되고 있다. 본 논문에서는 광전자소자를 선 왜곡 방식에 적용하여 광 송신기의 선형성을 향상시키는 방법을 제안하였다. 선 왜곡 방식은 두 개의 루프로 구성되어 있으며, 광 부품인 레이저 다이오드와 포토 다이오드 그리고 RF 부품인 위상변위기, 감쇄기, RF 결합/분배기, RF 증폭기를 사용하였다. 메인 루프에서 주 레이저 다이오드의 비선형성에 의해 발생된 왜곡신호성분은 보조 루프에서 부 레이저 다이오드를 이용하여 추출된 선 왜곡신호에 의해서 제거된다. 제안된 선형화 기법을 적용하여 2.4 GHz에서 선형화 기법을 적용하기 전보다 3차 상호변조 왜곡성분이 약 30dB 향상된 결과를 얻었다.

  • PDF

Analysis on Wind Turbine Degradation of the Shinan Wind Power Plant (신안풍력발전소 풍력터빈의 성능저하 분석)

  • Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.46-50
    • /
    • 2013
  • This paper investigated wind turbine degradation quantitatively by analyzing the short-term operation records of the Shinan Wind Power Plant. Instead of a capacity factor which is needed to be normalized its variability due to monthly wind speed change, this study suggests an analysis method by taking the difference between the theoretical power output calculated from the nacelle wind speed and actual power output as the quantitative index of performance degradation. For three-year SCADA data analysis of the Shinan Wind Power Plant, it was confirmed that power output degradation rate of 0.54% per year. This value is within the average reduction rate 0.4%/year~0.9%/year of normalized capacity factor of the onshore wind power plants in U.K. and Denmark; however, lower than the rate 2%/year of Canadian wind power plants.

A Feasibility Study of the Industrialization of Citrus's Functional Materials (감귤 기능성 물질 산업화 타당성 조사)

  • Ko, Seong-Bo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.568-571
    • /
    • 2010
  • 본 연구의 목적은 감귤 기능성물질의 산업화 타당성 분석을 하는 것이다. 구체적인 경제성 분석방법은 순현가와 투자수익률(내부수익률)을 이용한 기본적인 경제성분석과 손익분기점분석, 그리고 주요변수들의 변화에 따른 순현가의 변화를 파악하기위한 민감도분석이고, 정책적 분석은 감귤기능성 물질산업화가 감귤산업 전체에 미치는 파급효과를 계량적, 정성적으로 분석하였다. 감귤 기능성물질의 산업화 타당성 분석결과에 따르면, 미숙과 감귤 2만톤과, 감귤박 2만톤을 처리한다고 가정했을 경우 감귤산업에 미치는 경제적 효과는 연간 5백억원으로 나타났다. 이러한 막대한 경제적 효과는 본 사업에 투자되는 전체비용 약 1백억원, 10년 사업기간을 가정하면 연간 10억원의 설비투자비로 그의 50배의 경제적 파급효과를 나타날 수 있기 때문에 감귤기능성물질의 산업화효과는 매우 큰 것으로 나타났다.

  • PDF

An Analysis of Effect on Products Quality by Investment in Measurement Standards (측정표준 관련 투자가 제품의 품질에 미치는 효과 분석)

  • 안웅환;안병덕;박병선;정초시;김성태
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2004.04a
    • /
    • pp.127-132
    • /
    • 2004
  • 기업에서 올바른 품질관리를 수행하기 위해서는 1차적으로 품질수준을 결정하는 각각의 요인들에 대한 정확한 데이터의 확보가 필요하며, 이를 위한 측정(measurement) 수단 또한 매우 중요하다고 할 수 있다. 올바른 측정을 위해서는 양호한 측정기기 뿐만 아니라, 이를 효과적으로 다룬 수 있는 측정인력의 존재 통은 필수적 요건이라 할 수 있다. 따라서 본 연구에서는 제품 생산의 불량률에 대한 추정방정식으로 많이 사용되는 로짓(logit) 모형을 이용하여 기업의 측정표준 관련 투자가 제품의 품질에 미치는 효과를 분석하였는데, 그 결과 측정 및 풀질관리 인력, 측정설비 구입비 및 표준실 운영비 통의 측정 관련 투자, 인증표준물질의 사용이 제품생산의 불량률 감소를 가져와 제품의 풀질에 효과를 미치는 것으로 나타났다. 또한 기업의 측정표준 투자 결정요인을 분석한 결과, 기업의 연구개발 투자가 많을수록, 시장에서의 독점력이 높을수록, 기업규모가 클수록, 피리고 재무구조가 탄탄할수록 측정표준 투자가 큰 것으로 나타났다.

  • PDF

An advanced PRPD Pattern recognition method considering frequency analysis of the PD signals detected in GIS (PD 신호의 주파수 분석이 고려된 GIS 절연 결함 분류를 위한 Advanced PRPD 패턴인식)

  • Park, Jae-Hong;Jung, Seung-Yong;Ryu, Chel-Hwi;Kim, Young-Hong;Lee, Young-Jo;Lim, Yun-Sok;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1443-1444
    • /
    • 2007
  • 지속적으로 증가되는 전기에너지 공급의 신뢰성을 높이기 위하여 전력설비 주요 사고 원인인 부분방전(PD : Partial Discharge)을 검출하고 결함원의 패턴인식 방법의 개발 필요성 날로 증가되고 있다. 본 논문은 부분방전의 패턴인식 확률을 높이기 위하여 검출된 부분방전의 주파수 분석을 이용하여 Conventional PRPD Analysis 방법의 결함 판독확률을 향상시키기 위하여 Advanced PRPD를 제안 한다. 이를 위하여, GIS(Gas Insulated Switchgear)의 주요 사고원인으로 인식되어 있는 결함들을 인위적으로 제작 후 삽입하여 부분방전을 발생시켜 자체 설계 개발된 UHF 내장형 센서를 이용하여 검출하였다. 새로이 제안하는 방법과 기존의 PRPD 방법의 인식률을 상호 비교하기 위하여, 두 가지 그룹을, 즉, 기존의 방법에 의한 것과 부분방전의 주파수 분석이 포함된 방법에 의한 데이터그룹을 구축하고 학습방법은 동일한 인공신경망 MLP (Multilayer Perceptron)를 이용하여 인식률과 학습시간을 동시에 비교하였다. 상호 비교 결과에 의하면, 후자의 방법이 인식확률 뿐만아니라 학습시간도 좋은 결과가 나타났다.

  • PDF

An Artificial Neural Network Based Phrase Network Construction Method for Structuring Facility Error Types (설비 오류 유형 구조화를 위한 인공신경망 기반 구절 네트워크 구축 방법)

  • Roh, Younghoon;Choi, Eunyoung;Choi, Yerim
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.21-29
    • /
    • 2018
  • In the era of the 4-th industrial revolution, the concept of smart factory is emerging. There are efforts to predict the occurrences of facility errors which have negative effects on the utilization and productivity by using data analysis. Data composed of the situation of a facility error and the type of the error, called the facility error log, is required for the prediction. However, in many manufacturing companies, the types of facility error are not precisely defined and categorized. The worker who operates the facilities writes the type of facility error in the form with unstructured text based on his or her empirical judgement. That makes it impossible to analyze data. Therefore, this paper proposes a framework for constructing a phrase network to support the identification and classification of facility error types by using facility error logs written by operators. Specifically, phrase indicating the types are extracted from text data by using dictionary which classifies terms by their usage. Then, a phrase network is constructed by calculating the similarity between the extracted phrase. The performance of the proposed method was evaluated by using real-world facility error logs. It is expected that the proposed method will contribute to the accurate identification of error types and to the prediction of facility errors.

A Study on Characteristics for a Contract Power Conversion Factor and Analysis of a Maximum Utilization Factor of Transformer in Industrial Customers (산업용전력사용고객의 변압기최대이용률과 계약전력환산율에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.44-49
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of industrial customers is an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contact power and peak power for the last 5 years of each customer for 349 industrial customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is a lied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60(%).

A Study on Characteristics for a Contract Power Conversion Factor and Analysis of a Maximum Utilization Factor of Transformer in General Customers (일반용전력사용고객의 변압기최대이용률과 계약전력환산율 기준과의 비교 특성 연구)

  • Kim, Se-Dong;Wang, Yong-Peel
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.80-85
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of general customers is an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 461 general customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to estimate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60[%].

Accuracy evaluation of llluminance Calcuation methods Compared with the Monte-Carlo Simulation (몬테카를로 시뮬레이션을 위한 기준으로 한 조도 계산법의 정확도 평가)

  • 김창섭;심상만
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.2
    • /
    • pp.45-53
    • /
    • 1996
  • 평균조도 계산법 중에서 국내에서 주로 사용되는 3배광법과 ZCM의 정확도를 비교하고, 그 적용한계를 파악하였다. 비교방법은 전반확산형 조명기구와 직접식 조명기구에 대하여 3배광법과 ZCM에 의한 조명률을 계산하고, 이 값들을 이용하여 여러 상황하에서의 평균조도를 계산하였다. 몬테카를로 시뮬레이션으로 동일상황에서의 조도값을 구하고, 이 값과 3배광법과 ZCM의 조도값을 각각 비교하였다. MCS법의 정확도는 Moon위 해석적인 방법과 비교하여 입증하였다. 연구결과는 다음과 같다. 1. 방의 크기에 따른 평균조도 비교에서 전반확 형 조명기구와 직접식 조명기구의 경우 3배광법 보다 ZCM이 평균조도 오차가 적었다. 2. 광원의 수 변화에 따른 평균조도 비교에서 직접식 조명기구의 경우 3배광법은 광원의 수가 증가할수록 평균조도 오차가 감소하다가 다시 증가하였고 ZCM 은 점차적으로 감소하였다. 3. 실내면 반사율 변화에 따른 비교에서 직접식 조명기구의 경우 오차 범의가 3배광법에서 크고 ZCM에서 적게 나타냈다. 4. 방의 형태 변화에 따른 평균조도 비교에서 직접식 조명기구의 경우 방의 폭이 좁고 길이가 긴 공간에서 3배광법과 ZCM모두 오차가 크게 낱났다. 또 정방형에서 가까울수록 오차는 작아지면서 3배광법 보다 ZCM의 오차가 적었다. 그러므로 우리나라에서 혼용되고 있는 3배광법과 ZCM중에서 정확도가 높은 ZCM선택이 바람직하다.