• Title/Summary/Keyword: 설비소음

Search Result 320, Processing Time 0.038 seconds

Analysis of frequency characteristics and evaluation methods of elevator noise (승강기 소음의 주파수 특성 분석 및 평가 방법 고찰)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.607-614
    • /
    • 2021
  • Research on elevator noise has mainly focused on the cause of its occurrence and measures to reduce it. There is still insufficient research on how to accurately measure and evaluate elevator noise. There is a measurement method established as an international standard for the measurement method, but it is also difficult to apply to high-rise apartments, and there are many cases that do not closely reflect the characteristics of elevator noise. In order to solve this problem, a study was conducted to improve the elevator noise measurement method in the current standard. In this study, the characteristics of elevator noise were closely identified. Through frequency analysis of the elevator noise and other equipment, it was verified that the elevator noise is noise with different characteristics from other equipment. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. The correlation between bang machine and rubber ball was found to be very high at 0.9 level. As a result, it was verified that the mid-low frequency band of the elevator noise is the main structural transmission noise and cannot be evaluated together with other equipment.

Noise influence Coming to Existing Neighborhood Area by Extension of Power Site and Noise Reduction Service (발전소 증절이 부지경계의 가존 지역에 미지는 소음영향과 저감 대책)

  • Kim, Yeon-Whan;Goo, Jae-Rayng;Bae, Chun-Hee;Kim, Kye-Yean;Yang, Dong-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.716-722
    • /
    • 2009
  • 4000MW급 유연탄발전소는 기존 500MW급 4기의 발전설비 운영조건에서 지역공동체는 긍정적이었으나, 500MW급의 증설 호기가 늘어나면서 지역 공동체는 발전소 증설과 관련하여 기존 동쪽 부지 경계지역의 소음환경에 대하여 부정적인 문제를 제기하였다. 2000MW급 증설이 진행되어온 4000MW급 발전소의 다양한 소음원에 의한 소음파워 증대와 증가방출 과도소음 에 대하여 고저가 다양한 주변지역에 미치는 영향음 평가하고자 3차원 모델링기법을 적용한다. 기존호기를 비롯한 전체의 발전소 전면부 소음원응 비교 시험결과 증가방출 소음 파워가 기존 설계의 변경 제작되어 기존호기에 비해 20~30dBA 높아져 동시 방출사 주변지역에 과도하게 영향을 미치는 상태였으며 500MW급 4기를 추가 증설에 따라 일상소음원에 의한 소음 영향도 증설전 대비 2~3dBA 증가된 것으로 평가되었다. 따라서 증설호기의 과도 소음원 제거 방안으로 대가 방출증가가 회수되도록 증설호기의 증가방출설비를 개선하였고, 증설에 의하여 증가된 소음 영향음 저감하고자 기존 경계지역에 미치는 소음원음 고려하여 방음벽음 설치한 결과 47 ~ 49dBA를 나타내고 인근 주거건물의 전면부 소음은 43dBA이었다.

  • PDF